trumeter 34xx-0xxx Electronic Totalizers and Hour Meters Instruction Manual

June 17, 2024
trumeter

trumeter 34xx-0xxx Electronic Totalizers and Hour Meters

Specifications

  • Model: 34 Electronic Totalizers and Hour Meters
  • Display: LCD 0.28 [7mm] high figures black on light background
  • Input Options: 10-300VDC, 20-300VAC, Dry Contact
  • Power: Self-powered battery life 10+ years
  • Enclosure: NEMA 4/4X, 12 & IP66 compliant
  • Weight: 1 oz. [28g]

Product Usage Instructions

Mounting Options
Choose the appropriate mounting option based on your requirements:

  • Two Hole Mount (34xx-0xx, 3400-GATE): Dimensions: 1.750″ x 1.09″ x 1.44″
  • Three Hole Mount (34xx-1xx): Dimensions: 1.98″ x 0.78″ x 2.21″
  • Rectangular Flush Mount (34xx-2xx) and Round Flush
    Mount (34xx-3xx):
    Refer to the specific dimensions for each mount type.

Wiring Instructions
Follow the wiring diagrams provided to correctly connect the inputs:

  • 34×0-xxxx: 10-300VDC / 20-300VAC Input
  • 34×1-xxxx: Dry Contact Input
  • 34×3-xxxx: 4.5-30VDC Input

Reset Options
Choose the appropriate reset option based on your needs:

  • 34xx-xx0x: Non-Reset
  • 34xx-xx1x: Remote Reset / Dry Contact (switch)
  • 34xx-GATE: Non-Reset / Optional Remote Reset

Model 34

Electronic totalizers and hour meters

trumeter-34xx-xxx-Electronic-Totalizers-and-Hour-
Meters-

Common Specification

trumeter-34xx-xxx-Electronic-Totalizers-and-Hour-
Meters-1 trumeter-34xx-xxx-Electronic-
Totalizers-and-Hour-Meters-2

Dimensions

(All dimensions are nominal)

trumeter-34xx-xxx-Electronic-Totalizers-and-Hour-
Meters-3 trumeter-34xx-xxx-Electronic-
Totalizers-and-Hour-Meters-3 trumeter-
34xx-xxx-Electronic-Totalizers-and-Hour-Meters-4

Wiring Diagrams

Inputs do not have a polarity and can be wired either way round.

trumeter-34xx-xxx-Electronic-Totalizers-and-Hour-
Meters-5

CAUTION : RISK OF ELECTRIC SHOCK. INSTALLATION MUST BE CARRIED OUT BY SUITABLY QUALIFIED AND COMPETENT PERSONNEL ONLY. HAZARDOUS VOLTAGES MAY BE PRESENT ON THE CONNECTION.
THIS PRODUCT CONTAINS AN INTERNAL LITIUM BATTERY. DISPOSE OF IN ACCORDANCE WITH LOCAL REQUIREMENTS

Trumeter (Europe)

  • Pilot Mill, Alfred Street, Bury, Lancashire BL9 9JR, United Kingdom
  • Tel: +44 161 674 0960
  • Email: sales.uk@trumeter.com

Trumeter (Americas)

Trumeter (Americas)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals