AIGOSTAR FL01FN-10 840 LED Sensor Slim Flood Light Instruction Manual

June 17, 2024
aigostar

AIGOSTAR FL01FN-10 840 LED Sensor Slim Flood Light Instruction Manual
IGOSTAR LED Sensor Slim Flood Light

LED SENSOR SLIM FLOOD LIGHT

![LED SENSOR

SLIM FLOOD LIGHT](https://manuals.plus/wp- content/uploads/2024/02/Screenshot_7-724.png)

![LED SENSOR

SLIM FLOOD LIGHT](https://manuals.plus/wp- content/uploads/2024/02/Screenshot_1-1107.png)
![LED SENSOR

SLIM FLOOD LIGHT](https://manuals.plus/wp- content/uploads/2024/02/Screenshot_2-1015.png)

SPECIFICATIONS

Power(W) 10W 20W 30W 50W
ERP certificate type(4000K) FL01FN-10/840 FLO2FN-20/840 FLO3FN-30/840

FLO5FN-50/840
ERP certificate type(6500K)| FL01FN-10/865| FLO2FN-20/865| FLO3FN-30/865| FLO5FN-50/865
CE certificate type| SH-FLO1 FN-10-S      SH-FLO2FN-20-S| SH-FLO3fN-30-S| SH- FLOVN-50-S          SH-FL1OFN-100-S
Input Voltage(AC)| AC 220-240V
Input Current(mA)| 45mA| 90mA| 134mA| 219mA| SOOmA
Power Factor| > 0.8| > 0.9| > 0.9| > 0.9| > 0.9
Color Temperature(K)| 4000K/6500K
Energy efficiency dass| F| F| F| F| F
Luminous Flux(Lm)| 950| 2050| 3160| 5400| 10950
CRI(Ra)| 80

Good sensitivity

TOOLS REQUIRED

Adjustable spanner; May need some of the power cable

NOTICE
When lamps are installed outdoors, waterproof junction box is required.
The external flexible cable or cord of this luminaire cannot be replaced; If the cord is damaged, the luminaire shall be destroyed.
The product has LED light source inside, and the light source of this product is not replaceable. Once the light source reaches its service life, the whole lamp shall be replaced.
This product contains a light source of energy efficiency class

-(EU)2019/2015. The connection leads should be connected to the screw terminal block. This terminal block should be put in the reinforced insulation terminal box. If this luminaire is used outside, then the terminal box should pass IP65 test. And please pay attention to the rated voltage, rated connecting capacity of the terminal block, when connecting the supply cord. LED sensor slim flood light should be installed on the ground or on the wall or on the fixed bracket. The height of the installed position should be less than 9 meters. Switch should be connected to live wire.

INSTALLATION (12)
Strictly follow these instructions for installing, avoid the intensity of power cable during installing. As photo:

  1. Installing the brackets
  2. Loosening the bolts on both sides of the bracket 3. Adjusting the flooding Angle of the flood light
  3. Tightening the bolts on both sides of the bracket
  4. Connecting the wiring of the flood light
  5. Turning on the power to make sure the light is working

WARRANTY
This product is warranted from manufacturing defect only. This warranty is valid for 2 year from the date of purchase. This warranty does not apply to damage caused by user wrong installation or abnormal wear and tear. The Corp gives no warranty against damage to any surface due to incorrect removing or applying this product.

INFRARED MOTION SENSOR INSTRUCTION FOR USE

SPECIFICATION
Power Source : 220-240V/AC
Power Frequency : 50/60Hz
Ambient Light : <3-2000LUX (adjustable)
Time Delay : Min. 10sec±3sec
Max.7min±2min
Rated Load : 10W, 20W, 30W, 50W, 100W
Detection Moving Speed : 0.6-1.5m/s
Detection Range : 120°
Detection Distance : 3-10m (<24) adjustable
Working Temperature : -20~+40
Working Humidity : <93%RH
Power Consumption : approx 0.5W
Installation Height : 1.8-2.5m

FUNCTION(③)

  1. Can identify day and night: The consumer can adjust work ambient light. It can work in the daytime and at night when it is adjusted on the “sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to the testing pattern.
  2. SENS adjustable: It can be adjusted according to using location. The detection distance of low sensitivity could be only 3m and high sensitivity could be10m which fits for large room.
  3. Time-Delay is added continually: When it receives the second induction signals within the first induction, it will restart to time from the moment.

INSTALLATION ADVICE
As the detector responds to changes in temperature, avoid the following situations:

  1. Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
  2. Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc .Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.

TEST()

  1. Turn the SENS knob clockwise on the maximum (+). Turn the LUX knob clockwise on the maximum (sun). Turn the TIME knob anti-clockwise on the minimum (-)..
  2. Switch on the power; the sensor and its connected lamp will have beginning no signal at the beginning. After Warm-up 30sec, the sensor can start work .If the sensor receives the induction signal, the lamp will turn on. While there is no another induction signal any more, the load should stop working within 10sec±3sec and the lamp would turn off.
  3. Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than 3LUX, the sensor would not work and the lamp stop working too. If the ambient light is less than 3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor should stop working within 10sec±3sec.
    Note : when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could not work!

SOME PROBLEM AND SOLUTIONS

  1. The load does not work:
    a. Please check if the connection of power source and load is correct.
    b. Please check if the load is good.
    c. Please check if the settings of working light correspond to ambient light.

  2. The sensitivity is poor:
    a. Please check if there is any hindrance in front of the detector to affect it to receive the signals.
    b. Please check if the ambient temperature is too high.
    c. Please check if the induction signal source is in the detection field.
    d. Please check if the installation height corresponds to the height required in the instruction.
    e. Please check if the moving orientation is correct.

  3. The sensor can not shut off the load automatically:
    a. Please check if there is continual signal in the detection field.
    b. Please check if the time delay is set to the maximum position
    c. Please check if the power corresponds to the instruction.

FL01FN-10/865
QR Coad

FL02FN-20/865
QR Coad

FL03FN-30/865

FL0SFN-50/865

FL10FN-100/865

FL10FN-100/865

FL20FN-200/865

FL01FN-10/840

FL02FN-20/840

FL03FN-30/840

FLOSFN-50/840

FL10FN-100/840

ITALIA MARKET SRL