Whirlpool WED9051Y Electric Dryer Instruction Manual

June 16, 2024
Whirlpool

Whirlpool WED9051Y Electric Dryer

Whirlpool-WED9051Y-Electric-Dryer-PRODUCT

Product Information

Specifications

  • Product Model Numbers: WED9050X, WED9051Y, WED9150W, WED9151X,WED9151Y, WED9250W, WED9270X, WED9371Y
  • Dimensions:
    • Front View: 27″ (686 mm) wide, 35 3/8″ (899 mm) tall
    • Side View: 29″ (736 mm) wide
    • Back View: 61/4″ (159 mm) deep
  • Clearance Requirements:
    • Minimum 5″ (102 mm) clearance behind the dryer for the exhaust vent with elbow
    • Recommended spacing allowed with tested spacing of 0″ (0 mm) clearance on sides and rear
    • Additional spacing should be considered for ease of installation and servicing
    • Additional clearances might be required for wall, door, and floor moldings
    • Additional spacing should be considered on all sides of the dryer to reduce noise transfer
  • Venting Requirements:
    • Exhaust venting: 4″ (102 mm) diameter vent is required
    • Rigid or flexible metal exhaust vent must be used
    • Exhaust hood must be at least 12″ (305 mm) from the ground or any object in its path
  • Electrical Requirements:
    • Single phase, 120/240 volt, 60 Hz, AC only electrical supply
    • Or 3 or 4 wire, 120/208 volt electrical supply (if specified on the serial/rating plate)
    • Requires a separate 30-amp circuit, fused on both sides of the line
    • Do not have a fuse in the neutral or grounding circuit
  • Water Requirements (Steam Models Only):
    • The dryer must be connected to a cold water faucet using new inlet hoses
    • Do not use old hoses
    • Do not overtighten to avoid damage to the coupling

Product Usage Instructions

Closet Installation (Stacked Washer and Dryer)
To install the dryer in a closet stacked with a washer, follow these steps:

  1. Ensure a minimum clearance of 6″ (152 mm) between the dryer and the washer.
  2. Allow a minimum clearance of 34″ (864 mm) from the floor to the top of the dryer.
  3. Provide a minimum clearance of 18″ (457 mm) from the front of the dryer to the back wall.
  4. Ensure a minimum clearance of 3″ (76 mm) on each side of the dryer.
  5. Install ventilation openings in the top and bottom of the closet door, or use louvered doors with equivalent ventilation openings.
  6. Consider additional spacing for ease of installation and servicing.
  7. Ensure proper clearances for wall, door, and floor moldings.
  8. Do not install any other fuel-burning appliance in the same closet as the dryer.

Cabinet Installation (Dryer Only)

To install the dryer in a cabinet, follow these steps:

  1. Ensure a minimum clearance of 7″ (178 mm) from the top of the dryer to the cabinet.
  2. Allow a minimum clearance of 39″ (990 mm) from the floor to the bottom of the cabinet.
  3. Provide a minimum clearance of 18″ (460 mm) from the front of the dryer to the back wall.
  4. Ensure a minimum clearance of 4″ (102 mm) on each side of the dryer.
  5. Consider additional spacing for ease of installation and servicing.

Custom Under Counter Installation (Dryer Only)

Note: Some models are not recommended for undercounter installation.

To install the dryer under a counter, follow these steps:

  1. Ensure a minimum clearance of 39″ (990 mm) from the floor to the top of the counter.
  2. Allow a minimum clearance of 18″ (460 mm) from the front of the dryer to the back wall.
  3. Ensure a minimum clearance of 1″ (25 mm) on each side of the dryer.

FAQ

Q: What are the recommended venting requirements?
A: The dryer should be exhausted to the outside using a 4″ (102 mm) diameter rigid or flexible metal exhaust vent. Do not use plastic or metal foil vent. The exhaust hood must be at least 12″ (305 mm) from the ground or any object that may obstruct the exhaust path.

Q: What are the electrical requirements for the dryer?
A: The dryer requires a single phase, 120/240 volt, 60 Hz, AC only electrical supply. It should be connected to a separate 30-amp circuit fused on both sides of the line. Do not have a fuse in the neutral or grounding circuit.

Q: Can I install the dryer in a closet?
A: Yes, you can install the dryer in a closet. Ensure a minimum clearance of 6″ (152 mm) between the dryer and any adjacent surfaces. Install ventilation openings in the top and bottom of the closet door, or use louvered doors with equivalent ventilation openings.

PRODUCT MODEL NUMBERS
W10443041B
05/2012
WED9050X, WED9051Y, WED9150W, WED9151X, WED9151Y, WED9250W, WED9270X, WED9371Y

DRYER DIMENSIONS

Whirlpool-WED9051Y-Electric-Dryer-1

NOTE: Most installations require a minimum 5″ (102 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements”.

Whirlpool-WED9051Y-Electric-Dryer-3

NOTE: Some models not recommended for undercounter installation.

Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested spacing of 0″ (0 mm) clearance on sides and rear.

  • Additional spacing should be considered for ease of installation and servicing.
  • Additional clearances might be required for wall, door, and floor moldings.
  • Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
  • For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilitation openings are acceptable.
  • Companion appliance spacing should also be considered.
  • No other fuel-burning appliance may be installed in the same closet as the dryer.

INSTALLATION REQUIREMENTS

ELECTRICAL REQUIREMENTS

To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit

WATER (STEAM MODELS ONLY) REQUIREMENTS
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.

VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4″ (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12″ (305 mm) from the ground or any object that may be in the path of the exhaust.

Exhaust hoods:

Recommended Styles:

Acceptable Style:

Determine vent path:

  • Select route that will provide straightest and most direct path outdoors.
  • Plan installation to use fewest number of elbows and turns.
  • When using elbows or making turns, allow as much room as possible.
  • Bend vent gradually to avoid kinking.
  • Use as few 90° turns as possible.

Determine vent length and elbows needed for best drying performance:

  • Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use.
    NOTE: Do not use vent runs longer than those specified in Vent System Chart. Exhaust systems longer than those specified will:

  • Shorten life of dryer.

  • Reduce performance, resulting in longer drying times and increased energy usage.

The “Vent System Charts” provide venting requirements that will help achieve best drying performance.

Standard Vent System Chart

Number of 90° elbows| Type of vent| Box/louvered hoods| Angled hoods
---|---|---|---
0| Rigid metal| 64 ft. (20 m)| 58 ft. (17.7 m)
1| Rigid metal|

54 ft. (16.5 m)

|

48 ft. (14.6 m)

2| Rigid metal| 44 ft. (13.4 m)|

38 ft. (11.6 m)

3| Rigid metal|

35 ft. (10.7 m)

|

29 ft. (8.8 m)

4| Rigid metal| 27 ft. (8.2 m)| 21 ft. (6.4 m)

**Long Vent System Chart***

Number of 90° elbows| Type of vent| Box/louvered hoods| Angled hoods
---|---|---|---
0| Rigid metal| 130 ft. (39.6 m)| 129 ft. (39.3 m)
1| Rigid metal|

125 ft. (38.1 m)

|

119 ft. (36.3 m)

2| Rigid metal| 115 ft. (35.1 m)|

109 ft. (33.2 m)

3| Rigid metal|

106 ft. (32.3 m)

|

100 ft. (30.5 m)

4| Rigid metal| 98 ft. (29.9 m)| 92 ft. (28.0 m)

For Model WED9051Y only.

NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.