namron 1402746 Touch Thermostat Instruction Manual
- June 17, 2024
- NAMRON
Table of Contents
INSTRUCTION MANUAL
NAMRON TOUCH TERMOSTAT
220-240V~ 50Hz
Button Operation
Time and date setting:
Time setting: Menu + up key to enter the time setting, up and down keys to
adjust the setting, short press M to confirm and switch to the next digit,
when reaching the last digit, long press M to confirm and exit or directly
confirm and exit without operation for more than 5S.
Short press:
Add key: Increase the set point.
Dec key: Reduce the set point.
Menu key: Switch mode Home and Away.
Long press:
In power-on state:
Menu key: Power on/ off;
Dec key&Add key: Enter advanced menu;
Base wiring
1/4:Load
2:Neutral wire;
3:Live wire;
5/6: External temperature sensor;
Electrical data:
- Power: 230V / 50Hz
- Circuit breaker: Max 16A
- Maximum load: 3600W
- 1-pole electronic relay
- Internal power supply with galvanic isolation
- Do not use self-regulating heating cable
- Do not use for contactor control
Advanced menu
Long press Dec key&Add key to enter advanced settings. Short press Menu key to switch setting items, short press Add or Dec key to set, long press Menu key to confirm the setting and exit, The setting items are as follows:
-
Device type:
0:Regulator 1:Thermostat(default) -
Regulator period:
15 min, 30 min(default), 45 min, 60min, 90 min (Thermostat mode skip this item) -
Sensor type:
0:Single internal(default) 1:Single external
2:Internal and external -
External sensor type:
0: 10K(default) 1: 12K 2:15K 3: 47K
(External sensor included in product is 10K) -
High temperature protection temperature:
Range: 20-95°C default: 27°C -
Swing:
Range:1-9°C default: 2°C -
Calibration:
Range: ±9°C default: 0°C -
Maximum target temperature:
Range: 35-95°C default: 35°C -
Minimum target temperature:
Range: 0-30°C default: 5°C -
Home mode temperature default:
22°C / 70% -
Away mode temperature default:
15°C / 30% -
Screen brightness:
Range: 0-10 default: 1(0 is dark mode, then it only lights up when the display is touched) -
Open window detection:
0: OFF 1: ON(default) -
Restart the system:
Display “==” and wait for 5S, the setting is successful -
Reset to factory settings:
Display “==” and wait for 5S, the setting is successful