JUMBO 5V 130ml Aromtherapy Diffuser User Manual

June 17, 2024
JUMBO

JUMBO 5V 130ml Aromtherapy Diffuser User Manual

Performance and feature

Lightly touching switch key can immediately provide delightfully fresh air and moisten the space that you wish. Color-changing LED lights will bright up your environment and create a pleasant atmosphere.

Method to operate

  1. One hand holds the humidifier’s bottom piece and the other hand holds the humidifier’s lid. Rotate anti-clockwise to take the lid off. If the cotton holder is in place, twist it anti-clockwise to remove it from the lid. Put the spring into the cotton holder (it may already be in place), and then insert the absorbent cotton into the holder, Pick up the humidifier lid and align the center of the lid with the center of the absorbent cotton and twist the cotton stick holder clockwise to secure it in place.
  2. Connect the USB cable with the humidifier at one end, and the other end to a direct USB port of a matching adapter such as a mobile phone charger or a computer (the computer should be switched on). The humidifier will enter the standby status.
  3. Fill the water container with appropriate amount of water, place the lid on the water container, secure it and then gently touch the ‘start’ button, the status light ring is gradient, the humidifier then gets into working status. It will start generating mist and the LED light will be ON with changing color. Touch again the button to turn it off.
  4. When the humidifier is used for the first time or being kept unused for long time, it may take around 15 minutes to start generating fog. That is the normal phenomenon as the absorbent cotton stick needs some time to absorb water. When the absorbent cotton stick is fully soaked, it will start generating mist. You may add 1-3 drops of Essential oil, after the humidifier starts generating mist in order to pleasantly perfume your space.
  5. Attention! You should regularly check that the water container has enough water for the safe operation of the machine. Never turn the machine on without water,

Note : For new humidifiers or long-term unused humidifiers, you may take out the cotton stick and soak it in water for 30 seconds before operating the machine. This will help the humidifier to begin generating mist faster.

Parameter

Input Voltage: 5V
Aerosolized Amount: 35-40ml/hour
Material: ABS+PP

Caution

  1. This machine’s power supply voltage is DC5V, please be sure to choose the correct power adapter for this machine.
    2. The humidifier shall be kept in a safe place, out of the reach of children.
    3. Please fill with fresh water (purified water is perfect) in order to ensure that the steam generated is clean. Do NOT use hot water. It’s forbidden to tum on the machine when there is no water in the tank. Otherwise it will affect the service life of the machine or damage the machine.
    4. If the machine is not being used for a while, disconnect the power. If the machine is not in use for a long time (longer than 3 days), please pull out the power cable, empty the water from the water container and wipe out thoroughly, then store it in a proper place.

  2. Please do not use sharp and hard object to touch atomization chip to avoid damage to the surface of the atomization chip. To clean the atomization piece, use a soft damp cloth to gently wipe it. The humidifier will soon resume working.

  3. Wipe the humidifier clean with a soft cloth; don’t leak any water into the humidifier lid. It’s forbidden to immerse the whole machine in any liquid. Do not use gasoline, alcohol or any other organic solvents. 7. If the power cable is damaged or under any other exceptional circumstances, it should be discarded. Do not attempt to repair it.

  4. Cleaning atomization chip regularly and change the absorbent cotton stick it is recommended to prolong the service life of the product.

  5. Please frequently change the water for good product operation and better steam quality.

Caution

  1. This machine’s power supply voltage is DC5V, please be sure to choose the correct power adapter for this machine.
  2. The humidifier shall be kept in a safe place, out of the reach of children.
  3. Please fill with fresh water (purified water is perfect) in order to ensure that the steam generated is clean. Do NOT use hot water. It’s forbidden to tum on the machine when there is no water in the tank. Otherwise it will affect the service life of the machine or damage the machine.
  4. If the machine is not being used for a while, disconnect the power. If the machine is not in use for a long time (longer than 3 days), please pull out the power cable, empty the water from the water container and wipe out thoroughly, then store it in a proper place.
  5.  Please do not use sharp and hard object to touch atomization chip to avoid damage to the surface of the atomization chip. To clean the atomization piece, use a soft damp cloth to gently wipe it. The humidifier will soon resume working.
  6. Wipe the humidifier clean with a soft cloth; don’t leak any water into the humidifier lid. It’s forbidden to immerse the whole machine in any liquid. Do not use gasoline, alcohol or any other organic solvents. 7. If the power cable is damaged or under any other exceptional circumstances, it should be discarded. Do not attempt to repair it.
  7. Cleaning atomization chip regularly and change the absorbent cotton stick it is recommended to prolong the service life of the product.
  8. Please frequently change the water for good product operation and better steam quality.

Unusual conditions

If the machine head is accidentally dropped into the water, please follow the below steps:

  1. Turn off the power, pull out power cable.
  2. Unscrew the machine lid and take out the absorbent cotton stick.
  3. Gently shake the lid and empty the internal water as soon as possible, place it in a safe area and let it naturally air dry for 24 hours.

Causes of breakdown

If break down occurs, please check the following: A. After switched on, if the machine does not work:

  1. Make sure that USB cable is properly connected to the adapter at one end and the machine at the other end.
  2. Confirm the adapter specifications according to the product specifications.
  3. Make sure the container has enough water to adequately cover the absorbent cotton stick. In case of water shortage, fill the appropriate amount of water in the container.
  4. Make sure that the cotton stick is fully wet.

B. The machine does not spray or sprays abnormally:

  1. When atomization chip is contaminated, please clean the atomization chip.
  2. If the absorbent cotton stick becomes contaminated or is very old, replace it and clean the cotton stick base, along with the water tank.
  3. Make sure that the cotton stick is fully wet.

**The top

**

**Cotton stick

**

**Cotton stick holder

**

Water tank

  1. Open the cover and fill the container with water.
  2. Remove the cotton stick from the pipe. Caution: do not remove the spring at the bottom.
  3. Put the stick into the water on both sides for about 15 seconds. For best results you can leave it in the water longer.
  4. Remove the stick from the water, place it back in the tube and then in the unit to start running.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals