MAGMATIC PSB121 Prisma Mini Bar 20 Wash Bar Light
OVERVIEW
©2021 MAGMATIC EFFECTS all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. MAGMATIC EFFECTS logo and identifying product names and numbers herein are trademarks of MAGMATIC EFFECTS. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-MAGMATIC brands and product names are trademarks or registered trademarks of their respective companies.
MAGMATIC EFFECTS and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
MAGMATIC EFFECTS | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax |
www.elationlighting.com |
sales@magmaticeffects.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The
Netherlands + 31 45 546 85 66 | +31 45 546 85 96 fax |
www.elationlighting.eu |
info@elationlighting.eu Elation Professional Mexico
| AC Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000 + 52
728-282-7070
CAUTION:
RISK GROUP 3 – RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION!THE FIXTURE
EMITS HIGH-INTENSITY WAVELENGTH OF ULTRAVIOLET LIGHT. WEAR PROPER EYE AND SKIN
PROTECTION.
DO NOT OPERATE FIXTURE WITH DAMAGED/MISSING EXTERNAL COVER OR PROTECTIVE LENS.
DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW (UV) LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE
LIGHT/RADIATION OUTPUT.
AVOID PROLONGED PERIODS OF EXPOSURE.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN. AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 FEET (3.3 METERS). INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUN-LIGHT EXPOSURE DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION MAY EXPERIENCE DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE.
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of
this document may be available online. Please check
www.elationlighting.com for the latest
revision/update of this manual before beginning installation and/or
programming.
Date| Document Version| Software Version| DMX Channel
Mode| Notes
---|---|---|---|---
10/29/20| 1| 1.0| Not applicable| Initial Release
10/05/21| 2| N/C| Not applicable| Updated Installation Instructions and
Mainte- nance Guidelines
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and
thoroughly before attempting to operate this device. These instructions
contain important safety and use information.
This product is intended to be used by professionally trained personnel only
and is not suitable for private use.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect
operating condition. Care-fully check the shipping carton for damage that may
have occurred during shipping. If the carton is damaged, carefully inspect the
device for damage, and be sure all accessories necessary to install and
operate the device have arrived intact. In the event that damage has been
found or parts are missing, please contact our customer support team for
further instructions. Please do not return this device to your dealer without
first contacting customer support. Please do not discard the shipping carton
in the trash. Please recycle whenever possible.
BOX CONTENTS
Phoenix Connector (x1)
Positive Wire Tip Sheath (x1)
Negative Wire Tip Shealth (x1)
CUSTOMER SUPPORT
Contact MAGMATIC customer service for any product-related service and
support needs. Also visit
forums.elationlighting.com with
questions, comments, or suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax
323-832-9142 |
sales@magmaticeffects.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET Voice: +31 45
546 85 63 | Fax: +31 45 546 85 96 |
support@elationlighting.eu
REPLACEMENT PARTS: Please visit
parts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
LIMITED WARRANTY (USA ONLY)
-
Magmatic Effects hereby warrants, to the original purchaser, Magmatic products to be free of manufacturing defects in material and workmanship for a period of two years (730 days) from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
-
For warranty service, send the product only to the Magmatic Effects factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Magmatic Effects will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Magmatic Effects shall have no liability whatsoever for loss and/or or damage to any such accessories, nor for the safe return thereof.
-
This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Magmatic Effects concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the Magmatic Effects factory unless prior written authorization was issued to purchaser by Magmatic Effects; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual. -
This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Magmatic Effects will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Magmatic Effects under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Magmatic Effects. All products covered by this warranty were manufactured after January 1, 1990, and bear identifying marks to that effect.
-
Magmatic Effects reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
-
No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Magmatic Effects in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Magmatic Effects be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
-
This warranty is the only written warranty applicable to Magmatic Effects products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
WARRANTY RETURNS (USA ONLY)
To obtain warranty service, a Return Material Authorization (RMA) number must
first be obtained from MAGMATIC. It is the Customer’s responsibility to
provide product proof of purchase and serial number by acceptable evidence
such as an invoice copy or an approved MAGMATIC Extended Warranty Certificate
(“EWC”) and any relevant maintenance records at the time warranty service is
sought. Failure to provide acceptable evidence of product proof of purchase or
EWC and any relevant maintenance records may be cause for denial of warranty
service.
Products returned for warranty service must be sent without any accessories (i.e., power, data, and safety cables, brackets, clamps, rigging hardware, frost filters, gel frames, barn doors, lenses, hoses, nozzles, rack mounting hardware, etc.), must be boxed using the original and/or suitable packaging materials (double-box and foam) that provides ample product protection for ground and/or air freight transit, and must be shipped freight pre-paid and insured to MAGMATIC in Los Angeles, CA or a MAGMATIC Authorized Service Center. The RMA number must be clearly written on the outside of the return box, and a brief description of the problem and the RMA number must be documented and included in the box.
Products returned for warranty service without an RMA number clearly marked on the outside of the package will be refused and returned to the shipper at the Customer’s expense. Products returned for warranty service, which are received damaged due to inadequate and/or improper packaging and/or due to damage caused by the shipping carrier, may incur additional repair charges before warranty service begins and/or may void this warranty. If any product accessories (included and/or optional) are shipped with the product, MAGMATIC and/or the MAGMATIC Authorized Service Center shall have no liability whatsoever for the loss and/or damage to any such accessories, nor the safe return thereof. If the requested warranty repairs or service (including parts replacement) are within the terms of this warranty, MAGMATIC will pay return ground transportation shipping charges to a single designated point within the United States.
SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Magmatic Effects is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.
WARNINGS
- PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED.
- THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
- DO NOT PLUG THIS UNIT INTO A DIMMER PACK NEVER OPEN THIS FIXTURE WHILE IN USE! UNPLUG POWER BEFORE SERVICING THE FIXTURE! NEVER TOUCH FIXTURES DURING OPERATION, AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURES!
- NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK – MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
- THE FIXTURE IS DUST-TIGHT AND PROTECTED AGAINST LOW-PRESSURE WATER JETS FROM ANY DIRECTION
SAFETY GUIDELINES
- DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before servicing.
- DO NOT shake fixture, and avoid brute force when installing and/or operating fixture.
- DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the power cord connectors are damaged and do not insert into the fixture securely and with ease. NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of similar power rating.
- DO NOT block any air ventilation slots.
- All fan and air inlets must remain clean and free of dust and debris.
- Allow approx. 6” (15cm) between the fixture and other devices or a wall for proper cooling.
- When installing fixtures in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, and always install fixtures with an appropriately rated safety cable.
- Always disconnect fixture from the main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, and NEVER pull out the plug by tugging the wire portion of the cord.
- During the initial operation of this fixture, light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
- Consistent operational breaks will ensure fixtures will function properly for many years.
- ONLY use the original packaging and materials to transport the fixture for service.
CAUTION
RISK GROUP 3 – RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION!THE FIXTURE
EMITS A HIGH-INTENSITY WAVELENGTH OF ULTRAVIOLET LIGHT. WEAR PROPER EYE AND
SKIN PROTECTION. DO NOT OPERATE FIXTURES WITH DAMAGED/MISSING EXTERNAL COVER
OR PROTECTIVE LENS. DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW (UV)
LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE
LIGHT/RADIATION OUTPUT.
AVOID PROLONGED PERIODS OF EXPOSURE.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN. AVOID
DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 FEET (3.3
METERS). INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUN-LIGHT
EXPOSURE DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION MAY
EXPERIENCE DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM
THIS FIXTURE.
MAINTENANCE GUIDELINES
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to ensure proper function, optimized light
output, and an extended life. The frequency of cleaning depends on the
environment in which the fixture operates: damp, smoky, or particularly dirty
environments can cause a greater accumulation of dirt on the fixture’s optics.
Clean the external lens surface periodically with a soft cloth to avoid
dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to ensure proper function and extended
life. There are no user-serviceable parts inside this fixture, please refer
all other service issues to an authorized MAGMATIC service technician. Should
you need any spare parts, please order genuine parts from your local MAGMATIC
dealer. Please refer to the following points during routine inspections:
- -A detailed electrical check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition in order to prevent overheating.
- Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out during normal operation, resulting in damage or injury as larger parts could fall.
- Check for any deformations on the housing, color lenses, rigging hardware, and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust or liquids to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s).
- Electric power supply cables must not show any damage, material fatigue, or sediments.
NEVER remove the ground prong from the power cable.
REASSEMBLY
In order to maintain the device’s IP rating following any maintenance or
repair procedure, the device fasteners should be tightened to the following
spec using a torque wrench:
Fastener | Torque Specification |
---|---|
M3x6 Lens Plate Screw (x7) | 4.0~7.2 lbf-in (4.6~8.3 kgf-cm) |
M4x6 Black Glass Diffusion Filter Screw (x4 per filter) | 5.0~9.6 lbf-in |
(5.8~11.1 kgf-cm)
M4x8 Rear Panel Screws (x10)| 5.0~9.6 lbf-in (5.8~11.1 kgf-cm)
CAUTION! DO NOT OVER-TORQUE THE SCREWS, AS DOING SO CAN RESULT IN LEAKAGE!
TO CONFIRM THE INTEGRITY OF THE DEVICE AFTER REASSEMBLY, TEST THE FIXTURE USING AN ELATION IP TESTER. CONTACT ELATION SERVICE FOR DETAILS.
OVERVIEW
- Lens
- Bracket Adjustment Screw (x2)
- Mounting Bracket (x2)
- Safety Cable Attachment Point (x2)
- Power/Data Cable
INSTALLATION INSTRUCTIONS
FLAMMABLE MATERIAL WARNING
Keep fixture a minimum of 5 feet (1.5 meters) away from flammable materials
and/or pyrotechnics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or
installations.
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.
Before rigging/mounting a single fixture or multiple interconnected fixtures for custom matrix designs to any metal truss/structure or placing the fixture(s) on any surface, a professional equipment in-staller MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accessories.
The ambient operating temperature range is from 14°F (-10°C) to 104°F (40°C).
Do not operate this fixture when the ambient temperature falls outside this range.
Fixture(s) should be installed outside walking paths, seating areas, and areas were unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing, or servicing. Allow approximately 15 minutes for the fixture to cool down before servicing.
Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable (not included) that meets all local, national, and country codes and regulations.
CLAMP INSTALLATION
This fixture features a pair of adjustable mounting brackets on the rear face,
as well as a safety cable attachment point located at each end of the rear
face, just outboard of the mounting brackets. (see the illustration below).
When mounting this fixture to truss, be sure to secure appropriately rated
clamps (not included) to the mounting brackets, and attach separate SAFETY
CABLES of the ap-propriate rating to each of the safety cable attachment
points.
SAFETY CABLE
ALWAYS ATTACH A SAFETY CABLE WHEN INSTALLING THIS FIXTURE IN A SUSPENDED
ENVIRONMENT TO ENSURE THAT THE FIXTURE WILL NOT FALL IN THE EVENT THAT THE
CLAMP FAILS.
RIGGING
Overhead rigging requires extensive experience, including but not limited to:
calculating working load limits, understanding the installation material being
used, and periodic safety inspection of all installation material and the
fixture. If you lack these qualifications, do not attempt the installation
yourself. Improper installation can result in bodily injury.\
BLACK GLASS DIFFUSION FILTER
This unit requires two (2) black glass diffusion filters (SKU# PSG820) for
full coverage of the lens. To install the black glass filters, simply align
the screw holes on the black glass filters with the matching screw holes on
the frame of the fixture’s lens. Insert and tighten four (4) M4x6 fasteners
per filter. See the image below for guidance.
DEGREE LENS
-
Turn the device over with the rear panel facing towards you. Use an M4x8 screwdriver to remove the ten (10) screws on the rear panel, then remove the top lens cover and waterproof seal.
-
Turn the device back over so that the lighting panel is facing towards you. Use an M3x6 screw-driver to remove the seven (7) screws located on the lens plate. Remove the lens plate.
-
Remove the standard lens.
-
Install the new 45-degree lens, then re-install the lens plate and secure it in place by re-installing and tightening the seven (7) screws that were removed in step 2.
-
Re-install the waterproof seal and the top lens cover, then secure these in place by re-installing and re-tightening the ten (10) screws on the rear panel that was removed in step 1.
-
After re-assembly is complete, verify that the fixture is fully sealed by using the IP Tester. Refer to the Maintenance Guidelines section of this manual.
SPECIFICATIONS
KEY FEATURES
IP65 Rated Exterior High-Power UV Wash Luminaire
Scoop LED Reflector Design
20 Degree Narrow Beam Angle
365nm Peak True UV Wavelength
Optional Black Glass Diffusion Filter
DYNAMIC EFFECTS
20 Degree Beam Angle
Variable Dimming Modes
High-Speed Electronic Strobe
Beam Uniformity
LCD Display
10 x 3W High Power UV Diode LEDs
20,000 Hour Average LED Life
CONTROL
Must use with Magmatic Prisma Driver 8 (SKU# PSD108)
CONNECTIONS
Hard Wired 9 ft (2.74m), 2-Conductor, 14 Gauge IP Rated Power/Data Pigtail
Cable
CONSTRUCTION / PHYSICAL / PERFORMANCE
Dimensions (LxWxH): 18.9 x 3.9 x 4.2 in. / 480 x 100 x 106.5 mm
Weight: 4.85 lbs / 2.2 kg
ELECTRICAL
Input Voltage: DC 0-36.7V
Power Consumption: 24.3 W
CERTIFICATIONS / QUALIFICATIONS / THERMAL
IP Rating: IP65 Rating
Approvals: ROHS, CE Approved
Cooling: Air Cooled
Maximum Temperature (Ambient): 113 degrees F (45 degrees C)
Minimum Temperature (Ambient): 14 degrees F (-10 degrees C)
WHAT’S INCLUDED
Phoenix Connector (x1)
Positive Wire Tip Sheath (x1)
Negative Wire Tip Sheath (x1)
OPTIONAL ACCESSORIES
Prisma Mini Bar 20 Black Glass (PSG820)
Prisma-MB45L 45-degree Lens (PSL450)
Specifications and documentation are subject to change without notice.