INSTALLATION AND OPERATING INSTRUCTIONS
Overhead Warmers
Models: FD, FDD, FDL & FDDL

FD Calrod Overhead Warmers

APW wyott FD Calrod Overhead Warmers

Intended for other than household use. Unit must be kept clear of combustibles at all times.

WARNING: For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Keep the area free and clear of combustibles. (See ANZI Z83.14B, 1991)
WARNING: Improper installation, operation, service or maintenance can cause property damage, injury or death. Read and understand these instructions thoroughly before positioning, installing, maintaining or servicing this equipment.
WARNING: California Residents Only. This product can expose you to chemicals including chromium which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Initial heating of appliance may generate smoke or fumes and must be done in a well ventilated area.
Overexposure to smoke or fumes may cause nausea or dizziness.
APW Wyott® cooking equipment has been engineered to provide you with year- round dependable service when used according to the instructions in this manual and standard commercial kitchen practices.

APW Wyott Food Service Equipment Company
1307 N. Watters Road, Suite 180 • Allen, TX 75013
972.908.6100 Phone 214.565.0976 Fax
+1.800.527.2100
www.apwwyott.com

OWNERS INFORMATION

General Information:

  1. Always clean equipment thoroughly before first use. (See general cleaning instructions).
  2. Check rating label for your model designation and electrical rating.
  3. For best results, use stainless steel countertops.
  4. All dimensions in parenthesis in centimeters unless noted.
  5. APW Wyott® Overhead Food warmers are constructed from high quality stainless steel and available in lengths from 18” to 72”. Utilizing a metal sheath-heating element with a specially designed reflector, these units give uniform heat over the entire holding surface.
  6. In Europe, contact an APW Wyott authorized service agency for replacement light bulbs.

Installation Instructions:
A. Always clean equipment thoroughly before first use (See cleaning instructions).
B. Provide the following clearances around food warmer:
Do not install closer than:
A = Minimum clearance (in inches) to Bottom Surface of unit from Tabletop
B = Minimum clearance (in inches) to Back of unit
C = Minimum clearance (in inches) to Sides of unit.

Clearances For Overheads

| High Wattage| Low Wattage
FDD/FDDL-18| 28| 12| 2| 24| 12| 2
FDD/FDDL-24| 28| 12| 2| 24| 12| 2
FDD/FDDL-30| 28| 12| 2| 24| 12| 2
FDD/FDDL-36| 28| 12| 2| 24| 12| 2
FDD/FDDL-42| 28| 12| 2| 24| 12| 2
FDD/FDDL-48| 28| 12| 2| 24| 12| 2
FDD/FDDL-54| 28| 12| 2| 24| 12| 2
---|---|---|---|---|---|---
FDD/FDDL-60| 28| 12| 2| 24| 12| 2
FDD/FDDL-66| 28| 12| 2| 24| 12| 2
FDD/FDDL-72| 28| 12| 2| 24| 12| 2
FD/FDL-18| 16| 2| 2| 16| 2| 2
FD/FDL-24| 16| 2| 2| 16| 2| 2
FD/FDL-30| 16| 2| 2| 16| 2| 2
FD/FDL-36| 16| 2| 2| 16| 2| 2
FD/FDL-42| 16| 2| 2| 16| 2| 2
FD/FDL-48| 16| 2| 2| 16| 2| 2
FD/FDL-54| 16| 2| 2| 16| 2| 2
FD/FDL-60| 16| 2| 2| 16| 2| 2
FD/FDL-66| 16| 2| 2| 16| 2| 2
FD/FDL-72| 16| 2| 2| 16| 2| 2

C. Consult foodwarmer rating label for model designation and correct operating voltage and amperage.
D. Ceiling mounting brackets are provided with each foodwarmer for chain or shelf mounting. Remove brackets form packaging and screws from ends of foodwarmer to attach brackets. Use four #10 screws or studs with locknuts for shelf mounting. For chain mounting, use #14 jack chain and “S” hooks.
E. Remote switches are recommended. Longer switch life will result from cooler switch mounting locations. Optional stainless steel remote toggle and infinite switch box kits are available. Installation of remote switch box by service personnel requires 7/8” conduit, 1/4” push-on terminals, and no. 14 AWG copper wire suitable for at least 90ºC. Mount remote box to flat surface with two #10 screws or studs with locknuts. All wires marked as shown on wiring diagram.
F. Optional tubular stands are available for permanently mounting foodwarmers to non-combustible countertops.
G. Optional portable legs are available for foodwarmers for use over non- combustible countertops.
H. Installation of cord sets by service personnel should utilize the strain relief, grounding stud, and porcelain wire nuts provided with foodwarmers.
I. If unit is supplied with a power cord, the appliance must be positioned so that the plug is accessible.
NOTE: to avoid burning or charring of materials in the surface below the foodwarmer use only above an all-metal structure such as a table or countertop. See minimum  clearance chart above.
** Remote switches are recommended for under shelf mounting. Longer switch life will result from cooler switch mounting locations.
General Operation Instructions:**

  1. All foodservice equipment should be operated by trained personnel.
  2. Do not allow your customers to come in contact with any surface labeled “CAUTION HOT”.
  3. Never hold food below 150°F (66°C).

Warranty Information:
Reliability Backed By APW Wyott’s Warranty:
All APW Wyott® Overhead Warmers are backed by a one year parts and labor warranty, including OnSite Service calls within 50 miles of authorized service technicians.
Service Information:
Service Hotline 800-733-2203

SAFETY INFORMATION

APW Wyott Overhead Warmers are designed, built and sold for commercial use and should be operated by trained personnel only. Clearly post all CAUTIONS, WARNINGS and OPERATING INSTRUCTIONS near each unit to insure proper operation and to reduce the chance of personal injury and/or equipment damage.
Always disconnect power before servicing the Overhead Warmer. Surfaces will remain hot after power has been turned off. Allow unit to cool before cleaning or servicing. Never clean the Overhead Warmer by immersing it in water. The Overhead Warmer is not protected against water jets; DO NOT CLEAN OVERHEAD WARMER WITH A WATER JET. Always clean equipment before first use.

SPECIFICATIONS

Electrical:
A. Single-phase operation at 120, 208, 230, and 240 volts. (See label on each unit).
B. Field-wired units provided with 7/8” conduit hole, 6” long leads, and porcelain wire nuts. For supply connections, use minimum no. 14AWGcopper wires suitable for at least 90ºC.
C. U.S. cord-connected units provided with following plug configuration:

  1. 120 volt up to 1440 watts =NEMA5-15P; 120 volt up to 1920 watts =NEMA5-20P
  2. 208 volt up to 2496 watts =NEMA6-15P; 208 volt up to 3328 watts =NEMA6-20P
  3. 240 volt up to 2880 watts =NEMA6-15P; 240 volt up to 3840 watts =NEMA6-20P

D. European cord-connected units provided with following plug configuration:

  1. Continental Europe 230 volt up to 3600 watts = Schuko CEE7/7
  2. UK 230 volt up to 2930 watts =Bs1363

If the supply cord is damaged, an authorized service agent or a similarly qualified person must replace it to avoid a hazard or voiding the warranty.
WARNING: Electrical shock hazard. Failure to follow the instructions in this manual could result in serious injury or death.

  • Electrical Ground is required on this appliance.
  • Do not modify the power supply cord plug. If it does not fit into the outlet, have the proper outlet installed by a qualified electrician
  • Do not use an extension cord with this appliance.
  • Check with a qualified electrician if you are unsure as to whether the appliance is properly grounded.

Overall Dimensions:APW wyott FD Calrod Overhead Warmers - Dimensions
1

OPERATION

A. All foodservice equipment should be operated by trained personnel.
B. Do not allow your customers to come in contact with any surface labeled “CAUTION HOT”.
C. Switch on unit. Place precooked product under heat source. Maximum heat coverage equivalent to unit length.
D. Never hold food below 150ºF.

CLEANING

A. Never clean any electrical unit by immersing it in water.
B. Never clean any electrical unit using water jets.
C. Disconnect power before cleaning or servicing units.
D. Clean unit daily. Use warm, soapy water. Mild cleansers and non-abrasive pads may be used to remove baked-on food.

TROUBLESHOOTING

A. Always ask and check:

  1. Is the unit connected to a live power source?
  2. Check the circuit breaker.
  3. Is the power switch on and pilot light illuminating?
  4. Check the rating label. Is the unit operating on proper voltage?

B. If the above checks out, and problems still exist, call an APW Wyott authorized service agency.
C. All service should be performed by an APW Wyott authorized service agency.

WIRING DIAGRAMS

APW wyott FD Calrod Overhead Warmers - WIRING DIAGRAMSAPW wyott FD Calrod Overhead Warmers - WIRING DIAGRAMS
1![APW wyott FD Calrod Overhead Warmers

PARTS LISTS

Model “FD” Overhead Warmers Replacement Parts Catalog
FD Followed By 18, 24, 30, 36, 42, 48, 54, 60, 66, or 72

Model

| Volts| High Wattage|

Low Wattage

---|---|---|---
FD18| 120| 400| 250
208| 400| 250
230| 368| 294
240| 400| 320
FD24| 120| 575| 350
208| 575| 350
230| 529| 322
240| 575| 350
FD30| 120| 760| 450
208| 760| 450
230| 698| 414
240| 760| 450
FD36| 120| 920| 575
208| 920| 575
230| 845| 529
240| 920| 575
FD42| 120| 1100| 675
208| 1100| 675
230| 1011| 620
240| 1100| 675
FD48| 120| 1265| 800
208| 1265| 800
230| 1162| 735
240| 1265| 800
FD54| 120| 1425| 925
---|---|---|---
208| 1425| 925
230| 1309| 850
240| 1425| 925
FD60| 120| 1600| 1050
208| 1610| 1050
230| 1479| 965
240| 1610| 1050
FD66| 208| 1800| 1160
230| 1654| 1066
240| 1800| 1160
FD72| 208| 1980| 1275
230| 1819| 1171
240| 1980| 1275

For complete style and option designation:
Add one suffix from each following categories after the model and length

Wattage Voltage Switch

H=High Wattage
L=Low Wattage| 1=120
V 2=208
V 3=240V| I=Infinite Control
T=Toggle Switch
R=Remote Control/Switch

Example: A warmer, 48” long, high wattage, 208v, with infinite control = OH48H2I
EXPLODED VIEW – FD18 THRU FD-72    ![APW wyott FD Calrod Overhead Warmers

Item

| Part N0.| Description| Item| Part N0.|

Description

---|---|---|---|---|---
1| 76835| HOUSING FD18| | 75859| ELEMENT FD42 240V 675W
76836| HOUSING FD24| 75806| ELEMENT FD48 120V 1265W
76837| HOUSING FD30| 75807| ELEMENT FD48 208V 1265W
76838| HOUSING FD36| 75808| ELEMENT FD48 240V 1265W
76839| HOUSING FD42| 75860| ELEMENT FD48 120V 800W
76840| HOUSING FD48| 75861| ELEMENT FD48 208V 800W
76841| HOUSING FD54| 75862| ELEMENT FD48 240V 800W
76842| HOUSING FD60| 75823| ELEMENT FD54 120V 1425W
76843| HOUSING FD66| 75824| ELEMENT FD54 208V 1425W
76844| HOUSING FD72| 75825| ELEMENT FD54 240V 1425W
| | 75863| ELEMENT FD54 120V 925W
| | 75864| ELEMENT FD54 208V 925W
2| 67005| TOGGLE SWITCH| 75865| ELEMENT FD54 240V 925W
3| 76100| SWITCH GUARD| 75817| ELEMENT FD60 120V 1600W
4| 55564-EGO| INFINITE CONTROL 120V| 75809| ELEMENT FD60 208V 1610W
87054-EGO| INFINITE CONTROL 208V| 75810| ELEMENT FD60 240V 1610W
87053-EGO| INFINITE CONTROL 240V| 75866| ELEMENT FD60 120V 1050W
5| 55825| KNOB| 75867| ELEMENT FD60 208V 1050W
6| 76805| REFLECTOR FD18| 75868| ELEMENT FD60 240V 1050W
76806| REFLECTOR FD24| 75826| ELEMENT FD66 208V 1800W
76807| REFLECTOR FD30| 75827| ELEMENT FD66 240V 1800W
76808| REFLECTOR FD36| 75869| ELEMENT FD66 208V 1160W
76809| REFLECTOR FD42| 75870| ELEMENT FD66 240V 1160W
76810| REFLECTOR FD48| 75811| ELEMENT FD72 208V 1980W
76811| REFLECTOR FD54| 75812| ELEMENT FD72 240V 1980W
76812| REFLECTOR FD60| 75871| ELEMENT FD72 208V 1275W
76813| REFLECTOR FD66| 75872| ELEMENT FD72 240V 1275W
76814| REFLECTOR FD72| |
7| 75801| ELEMENT FD18 120V 400W| |
75833| ELEMENT FD18 208V 400W| 8| 76801| COVER LARGE RH
75830| ELEMENT FD18 240V 400W| 9| 76802| COVER SMALL
75851| ELEMENT FD18 120V 250W| 10| 76106| ELEMENT GUARD
75873| ELEMENT FD18 208V 250W| 11| 76955| MOUNTING BRACKET
75874| ELEMENT FD18 240V 320W| 12| 67003| ON-OFF PLATE
75461| ELEMENT FD24 120V 575W| 13| 56530| PILOT LIGHT
75813| ELEMENT FD24 208V 575W| 14| | WIRE SET: SPECIFY MODEL NO.
75814| ELEMENT FD24 240V 575W| 15| 76189| INSULATION FD18 THRU FD72
75852| ELEMENT FD24 120V 350W| 16| 76190| INSULATION FD18
75875| ELEMENT FD24 208V 350W| 76191| INSULATION FD24
75876| ELEMENT FD24 240V 350W| 76192| INSULATION FD30
75802| ELEMENT FD30 120V 760W| 76193| INSULATION FD36
75820| ELEMENT FD30 208V 760W| 76194| INSULATION FD42
75831| ELEMENT FD30 240V 760W| 76195| INSULATION FD48
75853| ELEMENT FD30 120V 450W| 76196| INSULATION FD54
75877| ELEMENT FD30 208V 450W| 76197| INSULATION FD60
75878| ELEMENT FD30 240V 450W| 76198| INSULATION FD66
75803| ELEMENT FD36 120V 920W| 76199| INSULATION FD72
75804| ELEMENT FD36 208V 920W| 17| 76803| END PLATE
75805| ELEMENT FD36 240V 920W| 18| 76804| ELEMENT SUPPORT
75854| ELEMENT FD36 120V 575W|
75855| ELEMENT FD36 208V 575W| Parts Not Shown
75856| ELEMENT FD36 240V 575W| | 58004| SELF RETAINING FASTENER
75819| ELEMENT FD42 120V 1100W| 89087| 8-32 X 3/16 MACHINE SCREW
75821| ELEMENT FD42 208V 1100W| 88993| 10-32 X 3/8 NYLOCK MACHINE
75822| ELEMENT FD42 240V 1100W| 88909| 8-18 X 3/8 SHEET METAL (AB)
75857| ELEMENT FD42 120V 675W| 89059| #10 EXTERNAL LOCKWASHER
75858| ELEMENT FD42 208V 675W| 88961| 10-24 HEX NUT GREEN-GROUND

Model “FDL” Overhead Warmers Replacement Parts Catalog FDL Followed By 18, 24, 30, 36, 42, 48, 54, 60, 66, or 72

Model Volts High Wattage Low Wattage
FDL18 120 480 330
208 462 312
230 441 368
240 480 400
FDL24 120 655 430
208 637 412
230 602 395
240 655 430
FDL30 120 840 530
208 822 512
230 772 487
240 840 530
FDL36 120 1080 735
208 1044 699
230 992 676
240 1080 735
FDL42 120 1260 835
208 1224 799
230 1158 767
240 1260 835
FDL48 120 1425 960
208 1389 924
230 1309 882
240 1425 960
FDL54 120 1585 1085
--- --- --- ---
208 1549 1049
230 1456 997
240 1585 1085
FDL60 120 1840 1290
208 1796 1236
230 1700 1185
240 1850 1290
FDL66 208 1986 1346
230 1874 1286
240 2040 1400
FDL72 208 2166 1461
230 2039 1392
240 2220 1515

For complete style and option designation:
Add one suffix from each following categories after the model and length

Wattage Voltage Switch

Wattage
H=High
L=Low Wattage| 1=120V
2=208V
3=240V| I=Infinite Control
T=Toggle Switch
R=Remote Control/Switch

Example: A lighted warmer, 48” long, high wattage, 208v, with infinite control = OHL48H2I
EXPLODED VIEW – FDL18 THRU FDL-72APW wyott FD Calrod Overhead Warmers -
parts 1 FDL18 Thru 72 Lighted Overhead Warmers

Item| Part N0.| Description| Item| Part N0.| Description
---|---|---|---|---|---
1| 76845| HOUSING FDL18| | 75824| ELEMENT FD54 208V 1425W
76846| HOUSING FDL24| 75825| ELEMENT FD54 240V 1425W
76847| HOUSING FDL30| 75863| ELEMENT FD54 120V 925W
76848| HOUSING FDL36| 75864| ELEMENT FD54 208V 925W
76849| HOUSING FDL42| 75865| ELEMENT FD54 240V 925W
76850| HOUSING FDL48| 75817| ELEMENT FD60 120V 1600W
76851| HOUSING FDL54| 75809| ELEMENT FD60 208V 1610W
76852| HOUSING FDL60| 75810| ELEMENT FD60 240V 1610W
76853| HOUSING FDL66| 75866| ELEMENT FD60 120V 1050W
76854| HOUSING FDL72| 75867| ELEMENT FD60 208V 1050W
| | 75868| ELEMENT FD60 240V 1050W
| | 75826| ELEMENT FD66 208V 1800W
2| 67004| TOGGLE SWITCH| 75827| ELEMENT FD66 240V 1800W
3| 76100| SWITCH GUARD| 75869| ELEMENT FD66 208V 1160W
4| 55564-EGO| INFINITE CONTROL 120V| 75870| ELEMENT FD66 240V 1160W
87054-EGO| INFINITE CONTROL 208V| 75811| ELEMENT FD72 208V 1980W
87053-EGO| INFINITE CONTROL 240V| 75812| ELEMENT FD72 240V 1980W
5| 55825| KNOB| 75871| ELEMENT FD72 208V 1275W
6| 76805| REFLECTOR FD18| 75872| ELEMENT FD72 240V 1275W
76806| REFLECTOR FD24| |
76807| REFLECTOR FD30| |
76808| REFLECTOR FD36| |
76809| REFLECTOR FD42| |
76810| REFLECTOR FD48| 8| 76801| COVER LARGE
76811| REFLECTOR FD54| 9| 76802| COVER SMALL
76812| REFLECTOR FD60| 10| 76106| ELEMENT GUARD
76813| REFLECTOR FD66| 11| 76955| MOUNTING BRACKET
76814| REFLECTOR FD72| 12| 67003| ON-OFF PLATE
| | 13| 56530| PILOT LIGHT
| | 14| | WIRE SET: SPECIFY MODEL NO.
7| 75801| ELEMENT FD18 120V 400W| 15| 76159| END COVER RH DL
75833| ELEMENT FD18 208V 400W| 16| 89182| SNAP-IN BUSHING
75830| ELEMENT FD18 240V 400W| 17| 76189| INSULATION FD18 THRU FD72
75851| ELEMENT FD18 120V 250W| 18| 76190| INSULATION FD18
75873| ELEMENT FD18 208V 250W| 76191| INSULATION FD24
75874| ELEMENT FD18 240V 320W| 76192| INSULATION FD30
75461| ELEMENT FD24 120V 575W| 76193| INSULATION FD36
75813| ELEMENT FD24 208V 575W| 76194| INSULATION FD42
75814| ELEMENT FD24 240V 575W| 76195| INSULATION FD48
75852| ELEMENT FD24 120V 350W| 76196| INSULATION FD54
75875| ELEMENT FD24 208V 350W| 76197| INSULATION FD60
75876| ELEMENT FD24 240V 350W| 76198| INSULATION FD66
75802| ELEMENT FD30 120V 760W| 76199| INSULATION FD72
75820| ELEMENT FD30 208V 760W| 19| 76211| LIGHT SUPPORT DL18
75831| ELEMENT FD30 240V 760W| 76212| LIGHT SUPPORT DL24
75853| ELEMENT FD30 120V 450W| 76213| LIGHT SUPPORT DL30
75877| ELEMENT FD30 208V 450W| 76214| LIGHT SUPPORT DL36
75878| ELEMENT FD30 240V 450W| 76215| LIGHT SUPPORT DL42
75803| ELEMENT FD36 120V 920W| 76216| LIGHT SUPPORT DL48
75804| ELEMENT FD36 208V 920W| 76217| LIGHT SUPPORT DL54
75805| ELEMENT FD36 240V 920W| 76218| LIGHT SUPPORT DL60
75854| ELEMENT FD36 120V 575W| 76219| LIGHT SUPPORT DL66
75855| ELEMENT FD36 208V 575W| 76220| LIGHT SUPPORT DL72
75856| ELEMENT FD36 240V 575W| |
75819| ELEMENT FD42 120V 1100W| |
75821| ELEMENT FD42 208V 1100W| 20| 75917| TWIN LAMPHOLDER
75822| ELEMENT FD42 240V 1100W| 21| 75916| COATED LIGHT BULB 120V 40W
75857| ELEMENT FD42 120V 675W| 76874| COATED LIGHT BULB 240V 40W
75858| ELEMENT FD42 208V 675W| 22| 76803| END PLATE
75859| ELEMENT FD42 240V 675W| 23| 76804| ELEMENT SUPPORT
75806| ELEMENT FD48 120V 1265W|

Parts Not Shown

75807| ELEMENT FD48 208V 1265W| | 58004| SELF RETAINING FASTENER
75808| ELEMENT FD48 240V 1265W| 89087| 8-32 X 3/16 MACHINE SCREW
75860| ELEMENT FD48 120V 800W| 88993| 10-32 X 3/8 NYLOCK MACHINE
75861| ELEMENT FD48 208V 800W| 88909| 8-18 X 3/8 SHEET METAL (AB)
75862| ELEMENT FD48 240V 800W| 89059| #10 EXTERNAL LOCKWASHER
75823| ELEMENT FD54 120V 1425W| 88961| 10-24 HEX NUT GREEN-GROUND

Model “FDD” or “FDDL” Dual Overhead Warmers Replacement Parts Catalog FDD or FDDL Followed By 18, 24, 30, 36, 42, 48, 54, 60, 66, or 72

| High Wattage Units|

Low Wattage Units

---|---|---
Length| FDD Series| FDDL Series| FDD Series| FDDL Series
18| 120V 800W| 120V 880W| 120V 500W| 120V 580W
18| 208V 800W| 208V 862W| 208V 500W| 208V 562W
18| 230V 735W| 230V 809W| 230V 588W| 230V 662W
18| 240V 800W| 240V 880W| 240V 640W| 240V 720W
24| 120V 1150W| 120V 1230W| 120V 700W| 120V 780W
24| 208V 1150W| 208V 1212W| 208V 700W| 208V 762W
24| 230V 1057W| 230V 1130W| 230V 643W| 230V 717W
24| 240V 1150W| 240V 1230W| 240V 700W| 240V 780W
30| 120V 1520W| 120V 1600W| 120V 900W| 120V 980W
30| 208V 1520W| 208V 1582W| 208V 900W| 208V 962W
30| 230V 1396W| 230V 1470W| 230V 827W| 230V 901W
30| 240V 1520W| 240V 1600W| 240V 900W| 240V 980W
36| 120V 1840W| 120V 2000W| 120V 1150W| 120V 1310W
36| 208V 1840W| 208V 1964W| 208V 1150W| 208V 1274W
36| 230V 1690W| 230V 1837W| 230V 1057W| 230V 1204W
36| 240V 1840W| 240V 2000W| 240V 1150W| 240V 1310W
42| 120V 2200W| 120V 2360W| 120V 1350W| 120V 1510W
42| 208V 2200W| 208V 2324W| 208V 1350W| 208V 1474W
42| 230V 2021W| 230V 2168W| 230V 1240W| 230V 1387W
42| 240V 2200W| 240V 2360W| 240V 1350W| 240V 1510W
48| 120V 2530W| 120V 2690W| 120V 1600W| 120V 1760W
48| 208V 2530W| 208V 2654W| 208V 1600W| 208V 1724W
48| 230V 2324W| 230V 2471W| 230V 1470W| 230V 1617W
48| 240V 2530W| 240V 2690W| 240V 1600W| 240V 1760W
54| 120V 2850W| 120V 3010W| 120V 1850W| 120V 2010W
54| 208V 2850W| 208V 2974W| 208V 1850W| 208V 1974W
54| 230V 2618W| 230V 2765W| 230V 1700W| 230V 1846W
54| 240V 2850W| 240V 3010W| 240V 1850W| 240V 2010W
60| 120V 3200W| 120V 3440W| 120V 2100W| 120V 2340W
60| 208V 3220W| 208V 3406W| 208V 2100W| 208V 2286W
60| 230V 2958W| 230V 3178W| 230V 1929W| 230V 2150W
60| 240V 3220W| 240V 3460W| 240V 2100W| 240V 2340W
66| 208V 3600W| 208V 3786W| 208V 2320W| 208V 2506W
66| 230V 3307W| 230V 3527W| 230V 2131W| 230V 2352W
66| 240V 3600W| 240V 3840W| 240V 2320W| 240V 2560W
72| 208V 3960W| 208V 4146W| 208V 2550W| 208V 2736W
72| 230V 3637W| 230V 3858W| 230V 2342W| 230V 2563W
72| 240V 3960W| 240V 4200W| 240V 2550W| 240V 2790W

For complete style and option designation:
Add one suffix from each following categories after the model and length

Wattage Voltage Switch

Wattage
H=High
L=Low Wattage| 1=120V
2=208V
3=240V| I=Infinite Control
T=Toggle Switch
R=Remote Control/Switch

Example: A lighted dual warmer, 48” long, high wattage, 208v, with toggle switch = OHDL48H2T
EXPLODED VIEW – FDD OR FDDL18 THRU FDD OR FDDL-72APW wyott FD Calrod
Overhead Warmers - parts 2 FDD or FDDL18 Thru 72 Overhead Warmers

Item

| Part N0.| Description| Item| Part N0.|

Description

---|---|---|---|---|---
1| 76855| HOUSING FDD/FDDL18| | 75863| ELEMENT FD54 120V 925W
76856| HOUSING FDD/FDDL24| 75864| ELEMENT FD54 208V 925W
76857| HOUSING FDD/FDDL30| 75865| ELEMENT FD54 240V 925W
76858| HOUSING FDD/FDDL36| 75817| ELEMENT FD60 120V 1600W
76859| HOUSING FDD/FDDL42| 75809| ELEMENT FD60 208V 1610W
76860| HOUSING FDD/FDDL48| 75810| ELEMENT FD60 240V 1610W
76861| HOUSING FDD/FDDL54| 75866| ELEMENT FD60 120V 1050W
76862| HOUSING FDD/FDDL60| 75867| ELEMENT FD60 208V 1050W
76863| HOUSING FDD/FDDL66| 75868| ELEMENT FD60 240V 1050W
76864| HOUSING FDD/FDDL72| 75826| ELEMENT FD66 208V 1800W
| | 75827| ELEMENT FD66 240V 1800W
| | 75869| ELEMENT FD66 208V 1160W
2| 67004| TOGGLE SWITCH| 75870| ELEMENT FD66 240V 1160W
3| 76100| SWITCH GUARD| 75811| ELEMENT FD72 208V 1980W
4| 55564-EGO| INFINITE CONTROL 120V| 75812| ELEMENT FD72 240V 1980W
87054-EGO| INFINITE CONTROL 208V| 75871| ELEMENT FD72 208V 1275W
87053-EGO| INFINITE CONTROL 240V| 75872| ELEMENT FD72 240V 1275W
5| 55825| KNOB| |
6| 76985| REFLECTOR FD18 DIRECTED| |
76986| REFLECTOR FD24 DIRECTED| |
76987| REFLECTOR FD30 DIRECTED| |
76988| REFLECTOR FD36 DIRECTED| 8| 77151| COVER LARGE RH
76989| REFLECTOR FD42 DIRECTED| 9| 77155| COVER SMALL RH
76990| REFLECTOR FD48 DIRECTED| 10| 77157| ELEMENT GUARD
76991| REFLECTOR FD54 DIRECTED| 11| 76955| MOUNTING BRACKET
76992| REFLECTOR FD60 DIRECTED| 12| 67003| ON-OFF PLATE
76993| REFLECTOR FD66 DIRECTED| 13| 56530| PILOT LIGHT
76994| REFLECTOR FD72 DIRECTED| 14| | WIRE SET: SPECIFY MODEL NO.
| | 15| 76159| END COVER RH DL
| | 16| 89182| SNAP-IN BUSHING
7| 75801| ELEMENT FD18 120V 400W| 17| 76189| INSULATION FD18 THRU FD72
75833| ELEMENT FD18 208V 400W| 18| 76190| INSULATION FD18
75830| ELEMENT FD18 240V 400W| 76191| INSULATION FD24
75851| ELEMENT FD18 120V 250W| 76192| INSULATION FD30
75873| ELEMENT FD18 208V 250W| 76193| INSULATION FD36
75874| ELEMENT FD18 240V 320W| 76194| INSULATION FD42
75461| ELEMENT FD24 120V 575W| 76195| INSULATION FD48
75813| ELEMENT FD24 208V 575W| 76196| INSULATION FD54
75814| ELEMENT FD24 240V 575W| 76197| INSULATION FD60
75852| ELEMENT FD24 120V 350W| 76198| INSULATION FD66
75875| ELEMENT FD24 208V 350W| 76199| INSULATION FD72
75876| ELEMENT FD24 240V 350W| 19| 76211| LIGHT SUPPORT DL18
75802| ELEMENT FD30 120V 760W| 76212| LIGHT SUPPORT DL24
75820| ELEMENT FD30 208V 760W| 76213| LIGHT SUPPORT DL30
75831| ELEMENT FD30 240V 760W| 76214| LIGHT SUPPORT DL36
75853| ELEMENT FD30 120V 450W| 76215| LIGHT SUPPORT DL42
75877| ELEMENT FD30 208V 450W| 76216| LIGHT SUPPORT DL48
75878| ELEMENT FD30 240V 450W| 76217| LIGHT SUPPORT DL54
75803| ELEMENT FD36 120V 920W| 76218| LIGHT SUPPORT DL60
75804| ELEMENT FD36 208V 920W| 76219| LIGHT SUPPORT DL66
75805| ELEMENT FD36 240V 920W| 76220| LIGHT SUPPORT DL72
75854| ELEMENT FD36 120V 575W| |
75855| ELEMENT FD36 208V 575W| |
75856| ELEMENT FD36 240V 575W| 20| 75917| TWIN LAMPHOLDER
75819| ELEMENT FD42 120V 1100W| 21| 75916| COATED LIGHT BULB 120V 40W
75821| ELEMENT FD42 208V 1100W| 76874| COATED LIGHT BULB 240V 40W
75822| ELEMENT FD42 240V 1100W| 22| 77152| COVER LARGE LH
75857| ELEMENT FD42 120V 675W| 23| 76803| END PLATE
75858| ELEMENT FD42 208V 675W| 24| 77158| ELEMENT SUPPORT
75859| ELEMENT FD42 240V 675W| 25| 77156| COVER SMALL LH
75806| ELEMENT FD48 120V 1265W|

Parts Not Shown

75807| ELEMENT FD48 208V 1265W| | 58004| SELF RETAINING FASTENER
75808| ELEMENT FD48 240V 1265W| 89087| 8-32 X 3/16 MACHINE SCREW
75860| ELEMENT FD48 120V 800W| 88993| 10-32 X 3/8 NYLOCK MACHINE
75861| ELEMENT FD48 208V 800W| 88909| 8-18 X 3/8 SHEET METAL (AB)
75862| ELEMENT FD48 240V 800W| 89059| #10 EXTERNAL LOCKWASHER
75823| ELEMENT FD54 120V 1425W| 88961| 10-24 HEX NUT GREEN-GROUND
75824| ELEMENT FD54 208V 1425W| 46877| 1/8-27 X 3/4 NIPPLE
75825| ELEMENT FD54 240V 1425W| 46876| 1/8-27 NUT

IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment.
For Warranty Service and/or Parts, this information is required.
Model Number…………………..
Serial Number…………………..
Date Purchased…………….
Notes……………………………..

APW Wyott EQUIPMENT LIMITED WARRANTY

APW Wyott Foodservice Equipment Company warrants its equipment against defects in materials and workmanship, subject to the following conditions:
This warranty applies to the original owner only and is not assignable.
Should any product fail to function in its intended manner under normal use within the limits defined in this warranty, at the option of APW Wyott such product will be repaired or replaced by APW Wyott or its Authorized Service Agency. APW Wyott will only be responsible for charges incurred or service performed by its Authorized Service Agencies. The use of other than APW Wyott Authorized Service Agencies will void this warranty and APW Wyott will not be responsible for such work or any charges associated with same. The closest APW Wyott Authorized Service Agent must be used.
This warranty covers products shipped into the 48 contiguous United States, Hawaii, metropolitan areas of Alaska and Canada. There will be no labor coverage for equipment located on any island not connected by roadway to the mainland.
Warranty coverage on products used outside the 48 contiguous United States, Hawaii, and metropolitan areas of Alaska and Canada may vary. Contact the international APW Wyott distributor, dealer, or service agency for details.
Time Period
One year for parts and one year for labor, effective from the date of purchase by the original owner. The Authorized Service Agency may, at their option, require proof of purchase. Parts replaced under this warranty are warranted for the un-expired portion of the original product warranty only.
Exceptions

  • Gas/Electric Cookline: Models GCB, GCRB, GF, GGM, GGT, CHP-H, EF, EG, EHP. Three (2) Year Warranty on all component parts, except switches and thermostats. (2 additional years on parts only.)
  • Broiler Briquettes, Rock Grates, Cooking Grates, Burner Shields, Fireboxes: 90 Day Material Only. No Labor.
  • Heat Strips: Models FD, FDL, FDD, FDDL. Two (2) Year Warranty on element only. No labor second year.
  • Glass Windows, Doors, Seals, Rubber Seals, Light Bulbs: 90 Day Material Only. No Labor.

In all cases, parts covered by extended warranty will be shipped FOB the factory after the first year.
Portable Carry In Products
Equipment weighing over 70 pounds or permanently installed will be serviced on-site as per the terms of this warranty. Equipment weighing 70 pounds or under, and which is not permanently installed, i.e. with cord and plug, is considered portable and is subject to the following warranty handling limitations. If portable equipment fails to operate in its intended manner on the first day of connection, or use, at APW Wyott’s option or its Authorized Service Agency, it will be serviced on site or replaced.
From day two through the conclusion of this warranty period, portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in-warranty repairs. No mileage or travel charges are allowed on portable units after the first day of use. If the customer wants on-site service, they may receive same by paying the travel and mileage charges. Exceptions to this rule: (1) countertop warmers and cookers, which are covered under the Enhanced Warranty Program, and (2) toasters or rollergrills which have in store service.
Exclusions
The following conditions are not covered by warranty:

  • Equipment failure relating to improper installation, improper utility connection or supply and problems due to ventilation.
  • Equipment that has not been properly maintained, calibration of controls, adjustments, damage from improper cleaning and water damage to controls.
  • Equipment that has not been used in an appropriate manner, or has been subject to misuse or misapplication, neglect, abuse, accident, alteration, negligence, damage during transit, delivery or installation, fire, flood, riot or act of god.
  • Equipment that has the model number or serial number removed or altered.

If the equipment has been changed, altered, modified or repaired by other than an Authorized Service Agency during or after the warranty period, then the manufacturer shall not be liable for any damages to any person or to any property, which may result from the use of the equipment thereafter.
This warranty does not cover services performed at overtime or premium labor rates. Should service be required at times which normally involve overtime or premium labor rates, the owner shall be charged for the difference between normal service rates and such premium rates. APW Wyott does not assume any liability for extended delays in replacing or repairing any items beyond its control.
In all cases, the use of other than APW Wyott Authorized OEM Replacement Parts will void this warranty.
This equipment is intended for commercial use only. Warranty is void if equipment is installed in other than commercial application.
Water Quality Requirements
Water supply intended for a unit that has in excess of 3.0 grains of hardness per gallon (GPG) must be treated or softened before being used. Water containing over 3.0 GPG will decrease the efficiency and reduce the operation life of the unit.
Note: Product failure caused by liming or sediment buildup is not covered under warranty.
“THE FOREGOING WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSES AND CONSTITUTES THE ENTIRE LIABILITY OF APW WYOTT. IN NO EVENT DOES THE LIMITED WARRANTY EXTEND BEYOND THE TERMS STATED HEREIN.”

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

APW wyott User Manuals

Related Manuals