  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly

*** The construction of this fixture will be accomplished by first making all necessary electrical connections, hanging the fixture from the ceiling, and then installing the glass.

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

  1. Please refer to the hanging instruction sheet (I.S. 19) provided to hang this fixture. Then refer back to this sheet to install the glass.
  2. Prior to installing glass, it is necessary to install foam weather stripping in the roof of the fixture – see Drawing 3.
  3. Cut 3 strips approximately 1-1/2” long from the foam weather stripping provided in the parts bag with the fixture.

INSTRUCTION

  1. Fixture can now be lamped accordingly.
  2. The glass in this fixture is installed by lining up the three grooves (3) in the glass with the three tabs located inside the roof – see Drawing 1.
  3. To install glass (2) align grooves and slip glass up into roof. Turn glass clockwise to lock it in.

Drawing 1 – Flush Mount
INSTRUCTION

Drawing 2 – Chain Hung
INSTRUCTION

Drawing 3 – Post-Mount
INSTRUCTION

I.S. 18 wiring grounding instructions

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Cover open end of connectors with silicone sealant to form a watertight seal. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
  4. Please refer to the grounding instructions below to complete all electrical connections

grounding instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.

Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

Drawing 1 – Hanging Instruction
INSTRUCTION

Drawing 2 – Canopy Adjustment
INSTRUCTION

I.S. 19 hanging instructions

INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

Shut o electrical current before starting. If the fixture you are replacing isturned on and o by a wall switch, simply turn the switch o. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead. DO NOT restore current – either by fuse, breaker or switch – until the new fixture is completely wired and in place

  1. Fasten mounting strap provided – see (1) to outlet box ( A) with the two 8-32 screws ( 2) not Drawing 1 .
  2. Thread 2 – hex nuts( 3a) and ( 3b) onto threaded tubing ( 4).
  3. Thread one end of threaded tubing ( 4) into loop ( 5) a minimum of 1/2’’ to 3/4’’. Tighten hex nut ( 3a) against loop ( 5) to lock loop in position.
  4. Thread other end of threaded tube ( 4) into mounting strap approximately 1/2’’.
  5. Slip canopy ( B) over loop ( 5) and adjust height of loop so half of the threaded area on the loop is exposed – see Drawing 2 below. After loop height is adjusted, tighten hex nut (3b) up against mounting strap, tighten against mounting strap to lock loop and threaded tube in position.
  6. Remove mounting strap ( 1) from junction box ( A), and thread third hex nut ( 3c) onto end of threaded tube ( 4) above the mounting strap, tighten against mounting strap to lock assembly in position.
  7. Remount mounting strap to junction box.

INSTRUCTION

  1. Taking the chain, determine the length you require to hang the fixture.
  2. Attach one end of the chain to the top loop of the fixture.
  3. Now slip loop collar (6) and canopy (B) onto chain. — – see Drawing 2
  4. Attach other end of chain to loop (5). Get assistance for this step since fixture may be heavy and difficult to hold while attaching the chain.

INSTRUCTION

  1. Unwrap fixture lead wire and ground wire and weave them up through the chain.
  2. Slip fixture lead wire and ground wire through center of loop ( 5).
  3. Connect ground wire to mounting strap ( 1) using green ground screw ( GS).
  4. Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet ( I.S. 1 8) and follow all instructions to make all necessary wiring connections.
  5. Slip canopy up firmly against the ceiling and secure by turning the threaded collar ( 6) on loop ( 5) until tight.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals