OWNERS INFORMATION

General Information:

  1. Always clean equipment thoroughly before first use. (See general cleaning instructions).

  2. Check rating label for your model designation and electrical rating.

  3. For best results, use stainless steel countertops.

  4. All dimensions in parenthesis in centimeters unless noted.

  5. APW Wyott®
    Overhead Food warmers are constructed from high quality stainless steel and available in lengths from 18” to 72”. Utilizing a metal sheath-heating element with a specially designed reflector, these units give uniform heat over the entire holding surface.

  6. In Europe, contact an APW Wyott authorized service agency for replacement light bulbs.

Installation Instructions:

  • A. Always clean equipment thoroughly before first use (See cleaning instructions).

  • B. Provide the following clearances around food warmer:
    Do not install closer than:
    A = Minimum clearance (in inches) to Bottom Surface of unit from Tabletop
    B = Minimum clearance (in inches) to Back of unit
    C = Minimum clearance (in inches) to Sides of unit.Clearances For Overheads

     | High Wattage| Low Wattage
    FD/FDL-18| 16| 2| 2| 16| 2| 2
    FD/FDL-24| 16| 2| 2| 16| 2| 2
    FD/FDL-30| 16| 2| 2| 16| 2| 2
    FD/FDL-36| 16| 2| 2| 16| 2| 2
    FD/FDL-42| 16| 2| 2| 16| 2| 2
    FD/FDL-48| 16| 2| 2| 16| 2| 2
    FD/FDL-54| 16| 2| 2| 16| 2| 2
    FD/FDL-60| 16| 2| 2| 16| 2| 2
    FD/FDL-66| 16| 2| 2| 16| 2| 2
    FD/FDL-72| 16| 2| 2| 16| 2| 2

  • C. Consult foodwarmer rating label for model designation and correct operating voltage and amperage.

  • D. Ceiling mounting brackets are provided with each foodwarmer for chain or shelf mounting. Remove brackets form packaging and screws from ends of foodwarmer to attach brackets. Use four #10 screws or studs with locknuts for shelf mounting. For chain mounting, use #14 jack chain and “S” hooks.

  • E. Remote switches are recommended. Longer switch life will result from cooler switch mounting locations. Optional stainless steel remote toggle and infinite switch box kits are available.
    Installation of remote switch box by service personnel requires 7/8” conduit, 1/4” push-on terminals, and no. 14 AWG copper wire suitable for at least 90ºC. Mount remote box to flat surface with two #10 screws or studs with locknuts. All wires marked as shown on wiring diagram.

  • F. Optional tubular stands are available for permanently mounting foodwarmers to non-combustible countertops.

  • G. Optional portable legs are available for foodwarmers for use over non-combustible countertops.

  • H. Installation of cord sets by service personnel should utilize the strain relief, grounding stud, and porcelain wire nuts provided with foodwarmers.

  • I. If unit is supplied with a power cord, the appliance must be positioned so that the plug is accessible.

NOTE: to avoid burning or charring of materials in the surface below the foodwarmer use only above an all-metal structure such as a table or countertop. See minimum clearance chart above.
Remote switches are recommended for under shelf mounting. Longer switch life will result from cooler switch mounting locations.

WARNING: California Residents Only. This product can expose you to chemicals including chromium which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

WARNING: For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Keep the area free and clear of combustibles. (See ANZI Z83.14B, 1991)

WARNING: Improper installation, operation, service or maintenance can cause property damage, injury or death. Read and understand these instructions thoroughly before positioning, installing, maintaining or servicing this equipment.

Initial heating of appliance may generate smoke or fumes and must be done in a well ventilated area.
Overexposure to smoke or fumes may cause nausea or dizziness.
APW Wyott® cooking equipment has been engineered to provide you with year- round dependable service when used according to the instructions in this manual and standard commercial kitchen practices.

General Operation Instructions:

  1. All foodservice equipment should be operated by trained personnel.
  2. Do not allow your customers to come in contact with any surface labeled “CAUTION HOT”.
  3. Never hold food below 150°F (66°C).

Warranty Information:

Reliability Backed By APW Wyott’s Warranty:
All APW Wyott®
Overhead Warmers are backed by a one year parts and labor warranty, including OnSite Service calls within 50 miles of authorized service technicians.

Service Information:
Service Hotline 800-733-2203

SAFETY INFORMATION

APW Wyott Overhead Warmers are designed, built and sold for commercial use and should be operated by trained personnel only. Clearly post all CAUTIONS, WARNINGS and OPERATING INSTRUCTIONS near each unit to insure proper operation and to reduce the chance of personal injury and/or equipment damage.

Always disconnect power before servicing the Overhead Warmer. Surfaces will remain hot after power has been turned off. Allow unit to cool before cleaning or servicing. Never clean the Overhead Warmer by immersing it in water. The Overhead Warmer is not protected against water jets; DO NOT CLEAN OVERHEAD WARMER WITH A WATER JET. Always clean equipment before first use.

SPECIFICATIONS

Electrical:

  • A. Single-phase operation at 120, 208, 230, and 240 volts. (See label on each unit).

  • B. Field-wired units provided with 7/8” conduit hole, 6” long leads, and porcelain wire nuts. For supply connections, use minimum no. 14AWGcopper wires suitable for at least 90ºC.

  • C. U.S. cord-connected units provided with following plug configuration:
    1. 120 volt up to 1440 watts =NEMA5-15P; 120 volt up to 1920 watts =NEMA5-20P
    2. 208 volt up to 2496 watts =NEMA6-15P; 208 volt up to 3328 watts =NEMA6-20P
    3. 240 volt up to 2880 watts =NEMA6-15P; 240 volt up to 3840 watts =NEMA6-20P

  • D. European cord-connected units provided with following plug configuration:
    1. Continental Europe 230 volt up to 3600 watts = Schuko CEE7/7
    2. UK 230 volt up to 2930 watts =Bs1363
    If the supply cord is damaged, an authorized service agent or a similarly qualified person must replace it to avoid a hazard or voiding the warranty.

WARNING: Electrical shock hazard. Failure to follow the instructions in this manual could result in serious injury or death.

  • Electrical Ground is required on this appliance.
  • Do not modify the power supply cord plug. If it does not fit into the outlet, have the proper outlet installed by a qualified electrician
  • Do not use an extension cord with this appliance.
  • Check with a qualified electrician if you are unsure as to whether the appliance is properly grounded.

Overall Dimensions:

DIMENSIONS– FD
DIMENSIONS– FD

**DIMENSIONS– FDL

**

**DIMENSIONS– FDD & FDDL

**

DIMENSIONS– TUBULAR STAND KIT

FOR INSTALLATION ABOVE NONCOMBUSTIBLE SURFACE

DIMENSIONS– PORTABLE LEG KIT

FOR USE ABOVE NONCOMBUSTIBLE SURFACE

OPERATION

  • A. All foodservice equipment should be operated by trained personnel.
  • B. Do not allow your customers to come in contact with any surface labeled “CAUTION HOT”.
  • C. Switch on unit. Place precooked product under heat source. Maximum heat coverage equivalent to unit length.
  • D. Never hold food below 150ºF.

CLEANING

  • A. Never clean any electrical unit by immersing it in water.
  • B. Never clean any electrical unit using water jets.
  • C. Disconnect power before cleaning or servicing units.
  • D. Clean unit daily. Use warm, soapy water. Mild cleansers and non-abrasive pads may be used to remove baked-on food.

TROUBLESHOOTING

  • A. Always ask and check:
    1. Is the unit connected to a live power source?
    2. Check the circuit breaker.
    3. Is the power switch on and pilot light illuminating?
    4. Check the rating label. Is the unit operating on proper voltage?

  • B. If the above checks out, and problems still exist, call an APW Wyott authorized service agency.

  • C. All service should be performed by an APW Wyott authorized service agency

WIRING DIAGRAMS

WIRING– FD18-72

Remote Configuration
Remote Configuration

Infinite Control Configuration
Infinite Control Configuration

Toggle Switch Configuration
Toggle Switch Configuration

WIRING– FDL18-72

Remote Configuration
Remote Configuration

Infinite Control Configuration
Infinite Control Configuration

Toggle Switch Configuration
Toggle Switch Configuration

PARTS LISTS

Model “FD” Overhead Warmers Replacement Parts Catalog
FD Followed By 18, 24, 30, 36, 42, 48, 54, 60, 66, or 72

Model| Volts| High Wattage| Low Wattage| Model| Volts| High Wattage| Low Wattage
---|---|---|---|---|---|---|---
FD18| 120| 400| 250| FD54| 120| 1425| 925
208| 400| 250| 208| 1425| 925
230| 368| 294| 230| 1309| 850
240| 400| 320| 240| 1425| 925
FD24| 120| 575| 350| FD60| 120| 1600| 1050
208| 575| 350| 208| 1610| 1050
230| 529| 322| 230| 1479| 965
240| 575| 350| 240| 1610| 1050
FD30| 120| 760| 450| FD66| 208| 1800| 1160
208| 760| 450| 230| 1654| 1066
230| 698| 414| 240| 1800| 1160
240| 760| 450| FD72| 208| 1980| 1275
FD36| 120| 920| 575| 230| 1819| 1171
208| 920| 575| 240| 1980| 1275
230| 845| 529|
240| 920| 575
FD42| 120| 1100| 675
208| 1100| 675
230| 1011| 620
240| 1100| 675
FD48| 120| 1265| 800
208| 1265| 800
230| 1162| 735
240| 1265| 800

For complete style and option designation:
Add one suffix from each following categories after the model and length

Wattage Voltage Switch
H=High Wattage 1=120V I=Infinite Control
L=Low Wattage 2=208V T=Toggle Switch
3=240V R=Remote Control/Switch

Example: A warmer, 48” long, high wattage, 208v, with infinite control = OH48H2I

EXPLODED VIEW – FD18 THRU FD-72
EXPLODED VIEW – FD18 THRU FD-72

FD18 Thru 72 Overhead Warmers

Item| Part N0.| Description| Item| Part N0.| Description
1| 76835| HOUSING FD18|  | 75859| ELEMENT FD42 240V 675W
76836| HOUSING FD24| 75806| ELEMENT FD48 120V 1265W
76837| HOUSING FD30| 75807| ELEMENT FD48 208V 1265W
76838| HOUSING FD36| 75808| ELEMENT FD48 240V 1265W
76839| HOUSING FD42| 75860| ELEMENT FD48 120V 800W
76840| HOUSING FD48| 75861| ELEMENT FD48 208V 800W
76841| HOUSING FD54| 75862| ELEMENT FD48 240V 800W
76842| HOUSING FD60| 75823| ELEMENT FD54 120V 1425W
76843| HOUSING FD66| 75824| ELEMENT FD54 208V 1425W
76844| HOUSING FD72| 75825| ELEMENT FD54 240V 1425W
 |  | 75863| ELEMENT FD54 120V 925W
 |  | 75864| ELEMENT FD54 208V 925W
2| 67005| TOGGLE SWITCH| 75865| ELEMENT FD54 240V 925W
3| 76100| SWITCH GUARD| 75817| ELEMENT FD60 120V 1600W
4| 55564-EGO| INFINITE CONTROL 120V| 75809| ELEMENT FD60 208V 1610W
87054-EGO| INFINITE CONTROL 208V| 75810| ELEMENT FD60 240V 1610W
87053-EGO| INFINITE CONTROL 240V| 75866| ELEMENT FD60 120V 1050W
5| 55825| KNOB| 75867| ELEMENT FD60 208V 1050W
6| 76805| REFLECTOR FD18| 75868| ELEMENT FD60 240V 1050W
76806| REFLECTOR FD24| 75826| ELEMENT FD66 208V 1800W
76807| REFLECTOR FD30| 75827| ELEMENT FD66 240V 1800W
76808| REFLECTOR FD36| 75869| ELEMENT FD66 208V 1160W
76809| REFLECTOR FD42| 75870| ELEMENT FD66 240V 1160W
76810| REFLECTOR FD48| 75811| ELEMENT FD72 208V 1980W
76811| REFLECTOR FD54| 75812| ELEMENT FD72 240V 1980W
76812| REFLECTOR FD60| 75871| ELEMENT FD72 208V 1275W
76813| REFLECTOR FD66| 75872| ELEMENT FD72 240V 1275W
76814| REFLECTOR FD72|  |
7| 75801| ELEMENT FD18 120V 400W|  |
75833| ELEMENT FD18 208V 400W| 8| 76801| COVER LARGE RH
75830| ELEMENT FD18 240V 400W| 9| 76802| COVER SMALL
75851| ELEMENT FD18 120V 250W| 10| 76106| ELEMENT GUARD
75873| ELEMENT FD18 208V 250W| 11| 76955| MOUNTING BRACKET
75874| ELEMENT FD18 240V 320W| 12| 67003| ON-OFF PLATE
75461| ELEMENT FD24 120V 575W| 13| 56530| PILOT LIGHT
75813| ELEMENT FD24 208V 575W| 14|  | WIRE SET: SPECIFY MODEL NO.
75814| ELEMENT FD24 240V 575W| 15| 76189| INSULATION FD18 THRU FD72
75852| ELEMENT FD24 120V 350W| 16| 76190| INSULATION FD18
75875| ELEMENT FD24 208V 350W| 76191| INSULATION FD24
75876| ELEMENT FD24 240V 350W| 76192| INSULATION FD30
75802| ELEMENT FD30 120V 760W| 76193| INSULATION FD36
75820| ELEMENT FD30 208V 760W| 76194| INSULATION FD42
75831| ELEMENT FD30 240V 760W| 76195| INSULATION FD48
75853| ELEMENT FD30 120V 450W| 76196| INSULATION FD54
75877| ELEMENT FD30 208V 450W| 76197| INSULATION FD60
75878| ELEMENT FD30 240V 450W| 76198| INSULATION FD66
75803| ELEMENT FD36 120V 920W| 76199| INSULATION FD72
75804| ELEMENT FD36 208V 920W| 17| 76803| END PLATE
75805| ELEMENT FD36 240V 920W| 18| 76804| ELEMENT SUPPORT
75854| ELEMENT FD36 120V 575W|
75855| ELEMENT FD36 208V 575W| Parts Not Shown
75856| ELEMENT FD36 240V 575W|  | 58004| SELF RETAINING FASTENER
75819| ELEMENT FD42 120V 1100W| 89087| 8-32 X 3/16 MACHINE SCREW
75821| ELEMENT FD42 208V 1100W| 88993| 10-32 X 3/8 NYLOCK MACHINE
75822| ELEMENT FD42 240V 1100W| 88909| 8-18 X 3/8 SHEET METAL (AB)
75857| ELEMENT FD42 120V 675W| 89059| #10 EXTERNAL LOCKWASHER
75858| ELEMENT FD42 208V 675W| 88961| 10-24 HEX NUT GREEN-GROUND

Model “FDL” Overhead Warmers Replacement Parts Catalog
FDL Followed By 18, 24, 30, 36, 42, 48, 54, 60, 66, or 72

Model| Volts| High Wattage| Low Wattage| Model| Volts| High Wattage| Low Wattage
---|---|---|---|---|---|---|---
FDL18| 120| 480| 330| FDL54| 120| 1585| 1085
208| 462| 312| 208| 1549| 1049
230| 441| 368| 230| 1456| 997
240| 480| 400| 240| 1585| 1085
FDL24| 120| 655| 430| FDL60| 120| 1840| 1290
208| 637| 412| 208| 1796| 1236
230| 602| 395| 230| 1700| 1185
240| 655| 430| 240| 1850| 1290
FDL30| 120| 840| 530| FDL66| 208| 1986| 1346
208| 822| 512| 230| 1874| 1286
230| 772| 487| 240| 2040| 1400
240| 840| 530| FDL72| 208| 2166| 1461
FDL36| 120| 1080| 735| 230| 2039| 1392
208| 1044| 699| 240| 2220| 1515
230| 992| 676|
240| 1080| 735
FDL42| 120| 1260| 835
208| 1224| 799
230| 1158| 767
240| 1260| 835
FDL48| 120| 1425| 960
208| 1389| 924
230| 1309| 882
240| 1425| 960

For complete style and option designation:
Add one suffix from each following categories after the model and length

Wattage Voltage Switch
H=High Wattage 1=120V I=Infinite Control
L=Low Wattage 2=208V T=Toggle Switch
3=240V R=Remote Control/Switch

Example: A lighted warmer, 48” long, high wattage, 208v, with infinite control = OHL48H2I

EXPLODED VIEW – FDL18 THRU FDL-72
EXPLODED VIEW – FDL18 THRU FDL-72

FDL18 Thru 72 Lighted Overhead Warmers

Item| Part N0.| Description| Item| Part N0.| Description
1| 76845| HOUSING FDL18|  | 75824| ELEMENT FD54 208V 1425W
76846| HOUSING FDL24| 75825| ELEMENT FD54 240V 1425W
76847| HOUSING FDL30| 75863| ELEMENT FD54 120V 925W
76848| HOUSING FDL36| 75864| ELEMENT FD54 208V 925W
76849| HOUSING FDL42| 75865| ELEMENT FD54 240V 925W
76850| HOUSING FDL48| 75817| ELEMENT FD60 120V 1600W
76851| HOUSING FDL54| 75809| ELEMENT FD60 208V 1610W
76852| HOUSING FDL60| 75810| ELEMENT FD60 240V 1610W
76853| HOUSING FDL66| 75866| ELEMENT FD60 120V 1050W
76854| HOUSING FDL72| 75867| ELEMENT FD60 208V 1050W
 |  | 75868| ELEMENT FD60 240V 1050W
 |  | 75826| ELEMENT FD66 208V 1800W
2| 67004| TOGGLE SWITCH| 75827| ELEMENT FD66 240V 1800W
3| 76100| SWITCH GUARD| 75869| ELEMENT FD66 208V 1160W
4| 55564-EGO| INFINITE CONTROL 120V| 75870| ELEMENT FD66 240V 1160W
87054-EGO| INFINITE CONTROL 208V| 75811| ELEMENT FD72 208V 1980W
87053-EGO| INFINITE CONTROL 240V| 75812| ELEMENT FD72 240V 1980W
5| 55825| KNOB| 75871| ELEMENT FD72 208V 1275W
6| 76805| REFLECTOR FD18| 75872| ELEMENT FD72 240V 1275W
76806| REFLECTOR FD24|  |
76807| REFLECTOR FD30|  |
76808| REFLECTOR FD36|  |
76809| REFLECTOR FD42|  |
76810| REFLECTOR FD48| 8| 76801| COVER LARGE
76811| REFLECTOR FD54| 9| 76802| COVER SMALL
76812| REFLECTOR FD60| 10| 76106| ELEMENT GUARD
76813| REFLECTOR FD66| 11| 76955| MOUNTING BRACKET
76814| REFLECTOR FD72| 12| 67003| ON-OFF PLATE
 |  | 13| 56530| PILOT LIGHT
 |  | 14|  | WIRE SET: SPECIFY MODEL NO.
7| 75801| ELEMENT FD18 120V 400W| 15| 76159| END COVER RH DL
75833| ELEMENT FD18 208V 400W| 16| 89182| SNAP-IN BUSHING
75830| ELEMENT FD18 240V 400W| 17| 76189| INSULATION FD18 THRU FD72
75851| ELEMENT FD18 120V 250W| 18| 76190| INSULATION FD18
75873| ELEMENT FD18 208V 250W| 76191| INSULATION FD24
75874| ELEMENT FD18 240V 320W| 76192| INSULATION FD30
75461| ELEMENT FD24 120V 575W| 76193| INSULATION FD36
75813| ELEMENT FD24 208V 575W| 76194| INSULATION FD42
75814| ELEMENT FD24 240V 575W| 76195| INSULATION FD48
75852| ELEMENT FD24 120V 350W| 76196| INSULATION FD54
75875| ELEMENT FD24 208V 350W| 76197| INSULATION FD60
75876| ELEMENT FD24 240V 350W| 76198| INSULATION FD66
75802| ELEMENT FD30 120V 760W| 76199| INSULATION FD72
75820| ELEMENT FD30 208V 760W| 19| 76211| LIGHT SUPPORT DL18
75831| ELEMENT FD30 240V 760W| 76212| LIGHT SUPPORT DL24
75853| ELEMENT FD30 120V 450W| 76213| LIGHT SUPPORT DL30
75877| ELEMENT FD30 208V 450W| 76214| LIGHT SUPPORT DL36
75878| ELEMENT FD30 240V 450W| 76215| LIGHT SUPPORT DL42
75803| ELEMENT FD36 120V 920W| 76216| LIGHT SUPPORT DL48
75804| ELEMENT FD36 208V 920W| 76217| LIGHT SUPPORT DL54
75805| ELEMENT FD36 240V 920W| 76218| LIGHT SUPPORT DL60
75854| ELEMENT FD36 120V 575W| 76219| LIGHT SUPPORT DL66
75855| ELEMENT FD36 208V 575W| 76220| LIGHT SUPPORT DL72
75856| ELEMENT FD36 240V 575W|  |
75819| ELEMENT FD42 120V 1100W|  |
75821| ELEMENT FD42 208V 1100W| 20| 75917| TWIN LAMPHOLDER
75822| ELEMENT FD42 240V 1100W| 21| 75916| COATED LIGHT BULB 120V 40W
75857| ELEMENT FD42 120V 675W| 76874| COATED LIGHT BULB 240V 40W
75858| ELEMENT FD42 208V 675W| 22| 76803| END PLATE
75859| ELEMENT FD42 240V 675W| 23| 76804| ELEMENT SUPPORT
75806| ELEMENT FD48 120V 1265W| Parts Not Shown
75807| ELEMENT FD48 208V 1265W|  | 58004| SELF RETAINING FASTENER
75808| ELEMENT FD48 240V 1265W| 89087| 8-32 X 3/16 MACHINE SCREW
75860| ELEMENT FD48 120V 800W| 88993| 10-32 X 3/8 NYLOCK MACHINE
75861| ELEMENT FD48 208V 800W| 88909| 8-18 X 3/8 SHEET METAL (AB)
75862| ELEMENT FD48 240V 800W| 89059| #10 EXTERNAL LOCKWASHER
75823| ELEMENT FD54 120V 1425W| 88961| 10-24 HEX NUT GREEN-GROUND

IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or Parts, this information is required.
Model Number__
Serial Number___
Date Purchased__

LIMITED EQUIPMENT WARRANTY

APW warrants to the original purchaser of new APW’s products to be free from defects in material or workmanship, under normal and proper use and maintenance service as specified by APW and upon proper installation and start-up in accordance with the instructions supplied with each APW unit. APWs’ obligation under this warranty is limited to a period of one [1] year from the date of original installation, or eighteen [18] months from original invoice date, whichever occurs first.
Defects that occur as a result of normal use, within the time period and limitations defined in this warranty, will at APWs’ discretion have the parts replaced or repaired by APW or a APWs-authorized service agency.

THIS WARRANTY IS SUBJECT TO ALL LISTED CONDITIONS

Repairs performed under this warranty are to be performed by an APW authorized service agency. APW will not be responsible for charges incurred or service performed by non-authorized repair agencies. In all cases, the nearest APW- authorized service agency must be used. APW will be responsible for normal labor charges incurred in the repair or replacement of a warrantied product within 50 miles (80.5 km) of an authorized service agency. Time and expense charges for anything beyond that distance will be the responsibility of the owner.

All labor will need to be performed during regular service hours. Any overtime premium will be charged to the owner. For all shipments outside the U.S.A. and Canada, please see the International Warranty for specific details. It is the responsibility of the owner to inspect and report any shipping damage claims, hidden or otherwise, promptly following delivery. No mileage or travel charges will be honored on any equipment that is deemed portable. In general, equipment with a cord and plug weighing less than 50 lb. (22.7 kg) is considered portable and should be taken or shipped to the closest authorized service agency, transportation prepaid.

CONTACT

Should you require any assistance regarding the operation or maintenance of any APW Manufacturing; phone or email our service department. In all correspondence provide the model number and serial number of the unit needing service; include the voltage or gas type.
Normal Business Hours: 8:00 a.m. to 4:30 p.m. Central
Telephone: 800-264-7827 Tech Service Option 2
Email: TechService@partstown.com
www.apwwyott.com

WARRANTY EXCLUSIONS

THE FOLLOWING WILL NOT BE COVERED UNDER WARRANTY.

APWs’ sole obligation under this warranty is limited to either repair or replacement parts, subject to the additional limitations detailed below. This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty.

  • Any product which has not been used, maintained, or installed in accordance with the directions published in the appropriate installation sheet and/or owner’s manual, including incorrect gas or electrical connection. APW is not liable for any unit which has been mishandled, abused, misapplied, subjected to harsh chemicals, modified by unauthorized personnel, damaged by flood, fire, or other acts of nature [or God], or which have an altered or missing serial number.
  • Installation, labor, and job checkouts, calibration of heat controls, air and gas burner/bypass/pilot adjustments, gas or electrical system checks, voltage and phase conversions, cleaning of equipment, or seasoning of griddle surface.
  • Replacement of fuses or resetting of circuit breakers, safety controls, or reset buttons.
  • Replacement of broken or damaged glass components, quartz heating elements, and light bulbs.
  • Labor charges for all removable and consumable parts in gas charbroilers and hotplates, including but not limited to burners, grates, and radiants.
  • Any labor charges incurred by delays, waiting time, or operating restrictions that hinder a service technician’s ability to perform service.
  • Replacement of parts that fail or are damaged due to normal wear or labor for replacement of parts that can be replaced during a daily cleaning routine, such as but not limited to silicone belts, PTFE nonstick sheets, control labels, knobs, bulbs, fuses, quartz heating elements, baskets, racks, and grease drawers.
  • Any economic loss of business or profits.
  • Non-OEM parts. Use of non-OEM parts without APWs’ approval will void the warranty.
  • Units exceeding one [1] year from original installation date, or more than eighteen [18] months from original invoice date, whichever comes first.

ADDITIONAL WARRANTIES

  • Specific/chain-specific equipment may have additional and/or extended warranties.

The foregoing warranty is in lieu of any and all other warranties expressed or implied and constitutes the entire warranty.

Customer Service

APW Wyott • www.apwwyott.com/
265 Hobson St. • Smithville, TN 37166
Telephone: 800-527-2100

APW wyott

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

APW wyott User Manuals

Related Manuals