TUYA DG-85 Motion Detector Instruction Manual

June 1, 2024
Tuya

TUYA DG-85 Motion Detector

Specifications

  • Models: DG-85, DG-85DMF, DG-85DMT
  • Input Voltage: 9-16VDC
  • Current Drain: 30mA @ 12VDC
  • Detection Range: 11.6m * 11.6m
  • Alarm Output: NC > 100mA/28VDC
  • Anti White Light Resistance: >20000LUX
  • Installation Height: 2m-2.7m
  • Tamper Switch: NC 100mA/28VDC
  • PIR Section: Lens Date, NO. of Curtain Beams (11+11+9)*2 = 62
  • Tripping Indication: Indicator lights for about 10-30 seconds

Installation

General Guidelines
Follow the general guidelines outlined in the manual. Ensure proper positioning and connection of components as shown in the diagrams.

Anti-Pests Installation

  • Avoid direct sunlight and facing metal walls.
  • Ensure the installation base is stable and can support up to 20Kg.
  • Install the detector at a height of 2.2-2.4 meters to prevent pests from interfering.

Illustrated Installation Procedure

  1. Open holes on the base as instructed.
  2. Route cables into the base and secure it to the wall using screws.
  3. Wire up the terminal block following the provided diagram.

3 functions of coding switch:

  • Relay Mode: Set DIP switch accordingly for relay mode operation.
  • Bus Mode: Set DIP switch for bus mode operation to transmit signals and data via bus.

FAQ

  1. Q: Can the detector be used outdoors?
    A: Yes, the detector can be used indoors and outdoors to provide maximum protection.

  2. Q: How do I choose between relay mode and bus mode?
    A: Use the coding switch to select between relay mode and bus mode as per your requirements.

  3. Q: What is the recommended installation height for anti-pests protection?
    A: The recommended installation height for anti-pests protection is between 2.2-2.4 meters.

Brief Introduction

DG-85 is a kind of PIR intrusion detector integrating the most advanced security technology. It adopts 2 dual PIR sensors with high accuracy, intelligent digital chip, advanced ,<True Motion Recognition & Anti-pests>of tware technology, which can help it to make an accurate judgment of trueintruder or other interfer

  • ence that can cause wrong alarm. And it is with function of auto
  • matic memory of environmental change, which can avoid wro
  • ng alarm a used by hot & cold air, operation machine interfere
  • nce. It can prevent effectively the interference cause by a 25 kg past or 10 cats, insect, mouse, birds etc. Its super filter can be used indoor and outdoor. This has clear various interference that common PIR detector can’t overcome; and put an end to wrong alarm and miss alarm .DG-85 has two different working modes: bus mode and relay mode, can be used for all kinds of control panels on the market.

TUYA-DG-85-Motion-Detector-\(1\)

Specifications

  • Models: DG-85
    DG-85DMF
    DG-85DMT

  • Input Voltage 9-16VDC

  • Cyrrent Drain 30mA@ 12VDC

  • Detection Range 11.6m*11.6m

TUYA-DG-85-Motion-Detector-\(2\)

  • Alarm output:  NC.>100mA/28VDC
  • Anti white light resistance: 20000LUX
  • Installation height:2m-2.7m
  • Tamper switch:  NC.100mA/28VDC
  • PIR Section:Lens Date
  • NO.of Curtain Beams:  (11+11+9)*2=62
  • Tripping Indication: lndicator lights for about 10-30 seconds

TUYA-DG-85-Motion-Detector-\(3\)

  • Anti -EMI/RFI:  10V/m 10MHz-1000MHz
  • Motion test:  0.2m/s-3.5m/s(0.6ft-11ft)
  • Accessories: BR-1:Surface mounted swivel bracket,adjustable 30 down and 45 left/right.
  • Environmental:
  • Operating Temp: -10 C to 50 C(14 F to 122 F )
  • Humidity:  5%-95% RH
  • Storage Temp :-20 C to 60 C (-4 F to 40 F)
  • Physical
    Size(HWD):1768569mm

This device is coherent to Europe parliament direct 1999/5/EC necessary items and rules, and also coherent to the main spirits of radio and telecom terminal equipments on March 9 . 1999. The device also reaches the Canadian standard RSS-210. It can be used indoor and outdoor, which can reach its maximum protection and avoidance of above interference.

Installation

General Guidelines

TUYA-DG-85-Motion-Detector-\(4\)

  • No direct facing cold /hot source
  • No direct sun shine

TUYA-DG-85-Motion-Detector-\(5\)

  • Keep away from high pressure power

  • No facing metal wall

  • Installation base should be stable

Anti-pests installation

TUYA-DG-85-Motion-Detector-\(7\)

  • The upper part of the detection area is non anti-pests area
  • Never face the detector to the place that pests can climb up directly

TUYA-DG-85-Motion-Detector-\(8\)

  • Anti-pests weight 20Kg
  • The installation height of the detector is 2.2-2.4 meters can Anti-pests

Illustrated Installation Procedure

Open holes on base:

  • Mask the drilling porints and drill in the the wall.
  • Route the cables into the base via the rear channel.
  • Insert two nails and arrach the base to the wall with two screws.
  • Insert the bottom edge of the large PCB under this tab&press the top edge in.

Wire up the terminal block

TUYA-DG-85-Motion-Detector-\(10\)

function of coding switch

DG-85 has two different working modes:bus mode and relay mode,the mode choosing can be conducted by DIP switch.

Relay mode theswitch1ofDIP=OFF
When setting to the relay mode DG-85 transmits alarm and temper signal by relay as standard sensors, same as the figure, can be powered by contacted the power of panel and the “RED”,”BLK” of the sensor,”GRN”,”YEL” unused, on relay mode, the setting only can be amended by DIP switch and trim pot-ntiometer

Bus mode theswitch1ofDIP=ON
When setting to bus mode DG-85 transmits alarm, tamper signals and datas by bus,and setting the sensor as well. On bus mode, DG-85 can be directly connected with control panel. same as the figure, can be pow-red by contacted the power of panel and the “RED”,”BLK” of the sens-r,”GRN”,”YEL” connected with the corresponding terminals. On bus m-de,the setting can be amended by DIP switch and trim potentiometer, also can by system keypad(should be compated with system)get into programming mode.

Single or dual edge processing
This setting direct the DSP digital signal process working mode.Single side mode is used the normal situation few of interference. Both sides process(out/in analysis) mode can effectively reduce fault alarm. So, we recommend use this working mode when the sensor in stallated near interfere resource.

LED setting
LED light 5 second when detected the energy of the moving signal can result alarm enough, when the energy of the signal not enough, LED blink.

Setting of coding switch

TUYA-DG-85-Motion-Detector-\(14\)

Sensitivity adjustment:
The trim potentiometer will turn bigger when turn clockwise, reverse result when turn counter-colockwise 0.25s-2s

PCB height setting

TUYA-DG-85-Motion-Detector-\(11\)

Motion test to protected area

  • Install the cover, close the fastening position. Guarantee that the front and back cover close Tightly without any space or the looseness of anti-water cover can’t prevent humidity entering into the parts.
  • Crossing to any direction of the detection area, your walking will cause the LED indicator to light for 2-3 seconds (refer to the right diagram)
  • Perform motion test from contrary directions in order to confirm the boundary of two sides. Make confirmed that detection center pointing to the center of protected area.

Special comments

Even the most sophisticated detcetors can sometimes be defeated or may fail to warn due to :DC power failure/improper connection, malicious masking of the lens,tampering with the optical system, decreased sensitivity in ambient temperatures near that of the human body and unexpected failure of a component part.The above list includes the most common reasons for failure recommended that the detector and the entire alarm system be checked weekly, to ensure proper performance.An alarm system should not be regarded as a substitute for insurance. Home & property owners or renters should be prudent enough to continue insuring their lives & property, even though they are protected by an alarm system. This device has been tested and found to comply with the limits for a Class B digitaldevice, pursuant harmful interference in residential installations .This equipment generates,uses and can radiate radio frequency energy and ,if not installed and used in accordance with the instructions ,may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in aparticular installation .If this device does cause such interference , which can be verfied by turning the device off and on ,the user is encouraged to eliminate the interference by one or more of the following measures:

  • Increase the distance between the device and the receiver.
  • Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.

WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment.