Delfield F18MC52D Refrigerated Work Tables Salad Tables and Freezer Bases Instruction Manual
- June 17, 2024
- DELFIELD
Table of Contents
- F18MC52D Refrigerated Work Tables Salad Tables and Freezer Bases
- Important Warning And Safety Information
- Receiving and Inspecting the Equipment
- Serial Number Location
- Warranty Information
- Regulatory Certifications
- Specifications
- Installation
- Refrigerator Operation
- Freezer Operation
- Temperature Control Settings
- Pressure Control Settings
- Maintenance
- Wiring Diagrams
- Replacement Parts
- Replacement Part Assemblies
- Standard Labor Guidelines To Repair Or Replace Parts On Delfield
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
F18 SERIES
Service and Installation Manual
F18MC52D Refrigerated Work Tables Salad Tables and Freezer Bases
Refrigerated Work Tables, Salad Tables & Freezer Bases
Please read this manual completely before attempting to install or operate
this equipment! Notify carrier of damage! Inspect all components immediately.
Important Information
Read Before Use
Please Save These Instructions!
Important Warning And Safety Information
WARNING Read This Manual Thoroughly Before Operating, Installing, Or
Performing Maintenance On The Equipment.
WARNING Failure To Follow Instructions In This Manual Can Cause Property
Damage, Injury Or Death.
WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids
In The Vicinity Of This Or Any Other Appliance.
WARNING Unless All Cover And Access Panels Are In Place And Properly
Secured, Do Not Operate This Equipment.
WARNING This Appliance Is Not Intended For Use By Persons Who Lack
Experience Or Knowledge, Unless They Have Been Given Supervision Or
Instruction Concerning Use Of The Appliance By A Person Responsible For Their
Safety.
WARNING This Appliance Is Not To Be Played With.
WARNING Do Not Clean With Water Jet.
WARNING Do Not Use Electrical Appliances Inside The Food Storage
Compartment Of This Appliance.
CAUTION Observe the following:
- Minimum clearances must be maintained from all walls and combustible materials.
- Keep the equipment area free and clear of combustible material.
- Allow adequate clearance for air openings.
- Operate equipment only on the type of electricity indicated on the specification plate.
- Unplug the unit before making any repairs.
- Retain this manual for future reference.
Receiving and Inspecting the Equipment
Even though most equipment is shipped crated, care should betaken during unloading so the equipment is not damaged whilebeing moved into the building.
- Visually inspect the exterior of the package an skid or container. Any damage should be noted and reported to the delivering carrier immediately.
- If damaged, open and inspect the contents with the carrier.
- In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form.
- Request an inspection of the concealed equipment. This should be done within 10 days from receipt of the equipment.
- Check the lower portion of the unit to be sure legs or casters are not bent.
- Also open the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
- Freight carriers can supply the necessary forms upon request.
- Retain all crating material until an inspection has been made or waived.
Uncrating the Equipment
First cut and remove the banding from around the crate.
Remove the front of the crate material, use of some tools will be required. If
the unit is on legs remove the top of the crate as well and lift the unit off
the skid. If the unit is on casters it can be “rolled” off the skid.
Serial Number Location
The serial number on all self-contained F18 Series refrigerated work tables
and freezer bases is located on the electrical specifications tag affixed
inside the compressor section next to the pressure control.
On remote refrigerated bases with doors, the tag is inside the unit on the
coil side. On remote refrigerated bases with drawers, the tag is affixed to
the drawer divider. On remote freezer bases, the tag is located on the inside
back of the unit.
Always have the serial number of your unit available when calling for parts or
service. A complete list of authorized Delfield parts depots is available at
www.delfield.com.
©2013 The Delfield Company. All rights reserved. Reproduction without written
permission is prohibited. “Delfield” is a registered trademark of The Delfield
Company.
Warranty Information
Visit http://www.delfield.com/minisite/service/warranty_info to:
- Register your product for warranty.
- Verify warranty information.
- View and download a copy of your warranty.
Regulatory Certifications
Models are certified by:
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL)
Underwriters Laboratories of Canada (ULC)
Specifications
Remote Refrigerated Work Tables
Model| # Of Doors| Shelf Max
Load (lbs)| Base Volume FT³| Shelf Area FT²|
Volts/Hertz/ Phasz| Amps| BTU Load| EVAP. BTU/°TD
---|---|---|---|---|---|---|---|---
F18WR31| (1) 19”| 70| 7.56| 2.56| 115/60/1| 3.0| 383| 120/3°
F18WR39| (1) 27”| 124| 10.23| 3.95| 115/60/1| 3.0| 465| 120/4°
F18WR44| (2) 19”| 70| 12.14| 5.12| 115/60/1| 3.0| 605| 120/5°
F18WR52| (1) 19” & (1) 27”| 70/124| 15.12| 6.51| 115/60/1| 3.0| 686|
120/6°
F18WR60| (2) 27”| 124| 18.10| 7.90| 115/60/1| 3.0| 768| 120/6°
F18WR70| (2) 32”| 140| 21.23| 9.64| 115/60/1| 3.0| 869| 120/7°
F18WR79| (2) 27” & (1) 19”| 124/70| 24.48| 10.29| 115/60/1| 6.0| 1050|
240/4°
F18WR87| (3) 27”| 124| 27.46| 11.85| 115/60/1| 6.0| 1131| 240/5°
Self-Contained Refrigerated Work Tables
Model| # Of Doors| Shelf Max Load (lbs)
| Base Volume FT³
| Shelf Area FT²| Volts/Hertz/ Phase| Amps|
BTU Load| BTU System Cap.| R-404A oz.| H.P.| NEMA
Plug
---|---|---|---|---|---|---|---|---|---|---|---
F18WC39| (1) 19”| 70| 7.56| 2.56| 115/60/1| 8.0| 383| 1462| 16| 1/5|
5-15P
F18WC47| (1) 27”| 124| 10.23| 3.95| 115/60/1| 8.0| 465| 1462| 16| 1/5|
5-15P
F18WC52| (2) 19”| 70| 12.14| 5.12| 115/60/1| 8.0| 605| 1462| 16| 1/5|
5-15P
F18WC60| (1) 19” & (1) 27”| 70/124| 15.12| 6.51| 115/60/1| 8.0| 686|
1462| 16| 1/5| 5-15P
F18WC68| (2) 27”| 124| 18.10| 7.90| 115/60/1| 10.0| 768| 1462| 16| 1/4|
5-15P
F18WC78| (2) 32”| 140| 21.23| 9.64| 115/60/1| 10.0| 869| 1994| 16| 1/4|
5-15P
F18WC87| (2) 27” & (1) 19”| 124/70| 24.48| 10.29| 115/60/1| 10.0| 1050|
2261| 16| 1/4| 5-15P
F18WC95| (3) 27”| 124| 27.46| 11.85| 115/60/1| 10.0| 1131| 2261| 16|
1/4| 5-15P
Remote Refrigerated Mega Top Salad Tables
Model| # Of Doors| Shelf Max Load (lbs)
| Base Volume FT³
| # of Pans| Volts/Hertz/ Phase| Amps| BTU Load
Base/Rail| EVAP. BTU/°TD Base/Rail
---|---|---|---|---|---|---|---|---
F18MR31A| (1) 19”| 70| 4.14| 6| 115/60/1| 3.0| 280/265| 120/2°/12/22°
F18MR44A| (2) 19”| 70| 7.15| 6| 115/60/1| 3.0| 444/265| 120/4°/12/22°
F18MR44D| (2) 19”| 70| 7.15| 12| 115/60/1| 3.0| 444/529| 120/4°/22/25°
F18MR52A| (1) 19” & (1) 27”| 70/124| 8.97| 6| 115/60/1| 3.0| 515/265|
120/4°/12/22°
F18MR52D| (1) 19” & (1) 27”| 70/124| 8.97| 12| 115/60/1| 3.0| 515/529|
120/4°/22/25°
F18MR52E| (1) 19” & (1) 27”| 70/124| 8.97| 18| 115/60/1| 3.0| 515/794|
120/4°/31/26°
Self-Contained Refrigerated Mega Top Salad Tables
Model| # Of Doors| Shelf Max
Load (lbs)| Base Volume FT³
| # of Pans| Volts/Hertz/ Phase| Amps| BTU Load
Base/Rail| BTU System Cap. Base/Rail| R-404A
oz. | H.P.| NEM Plug
---|---|---|---|---|---|---|---|---|---|---|---
F18MC39A| (1) 19”| 70| 4.14| 6| 115/60/1| 10.0| 280/265| 1903/925| 16|
1/4| 5-15P
F18MC39D| (1) 19”| 70| 4.14| 12| 115/60/1| 10.0| 280/529| 1903/1156| 16|
1/4| 5-15P
F18MC52A| (2) 19”| 70| 7.15| 6| 115/60/1| 10.0| 444/265| 1903/925| 16|
1/4| 5-15P
F18MC52D| (2) 19”| 70| 7.15| 12| 115/60/1| 10.0| 444/529| 1903/1156| 16|
1/4| 5-15P
F18MC52E| (2) 19”| 70| 7.15| 18| 115/60/1| 10.0| 444/794| 1903/1321| 16|
1/4| 5-15P
F18MC60A| (1) 19” & (1) 27”| 70/124| 8.97| 6| 115/60/1| 10.0| 515/265|
2314/864| 16| 1/4| 5-15P
F18MC60D| (1) 19” & (1) 27”| 70/124| 8.97| 12| 115/60/1| 10.0| 515/529|
2314/1141| 16| 1/4| 5-15P
F18MC60E| (1) 19” & (1) 27”| 70/124| 8.97| 18| 115/60/1| 10.0| 515/794|
2314/1361| 16| 1/4| 5-15P
F18MC60F| (1) 19” & (1) 27”| 70/124| 8.97| 24| 115/60/1| 10.0| 515/1058|
2314/1540| 16| 1/4| 5-15P
Remote Refrigerated Salad Top Tables
Model| # Of Doors| Shelf Max Load (lbs)| Base Volume
FT3| # of Pans| Volts/Hertz/ Phase| Amps| BTU
Load Base/Rail| Evap. BTU/°TD Base/Rail
---|---|---|---|---|---|---|---|---
F18SR31A| (1) 19”| 70| 4.14| 6| 115/60/1| 3.0| 280/265| 120/2°/13/21°
F18SR44A| (2) 19”| 70| 7.15| 6| 115/60/1| 3.0| 491/441| 120/4°/13/21°
F18SR44B| (2) 19”| 70| 7.15| 8| 115/60/1| 3.0| 491/441| 120/4°/16/22°
F18SR44C| (2) 19”| 70| 7.15| 10| 115/60/1| 3.0| 491/441| 120/4°/19/23°
F18SR52A| (1) 19” & (1) 27”| 70/124| 8.97| 6| 115/60/1| 3.0| 532/529|
120/4°/13/21°
F18SR52B| (1) 19” & (1) 27”| 70/124| 8.97| 8| 115/60/1| 3.0| 532/529|
120/4°/16/22°
F18SR52C| (1) 19” & (1) 27”| 70/124| 8.97| 10| 115/60/1| 3.0| 532/529|
120/4°/19/23°
F18SR52D| (1) 19” & (1) 27”| 70/124| 8.97| 12| 115/60/1| 3.0| 532/529|
120/4°/23/23°
Self-Contained Refrigerated Salad Top Tables
Model| # Of Doors| Shelf Max Load (lbs)
| Base Volume FT³
| # of Pans| Volts/Hertz/ Phase| Amps| BTU Load
Base/Rail| BTU System Cap. Base/Rail| R-404A oz.| H.P.|
NEMA Plug
---|---|---|---|---|---|---|---|---|---|---|---
F18SC39A| (1) 19”| 70| 4.14| 6| 115/60/1| 10.0| 280/265| 1903/745| 16|
1/4| 5-15P
F18SC39B| (1) 19”| 70| 4.14| 8| 115/60/1| 10.0| 280/353| 1903/867| 16|
1/4| 5-15P
F18SC52A| (2) 19”| 70| 7.15| 6| 115/60/1| 10.0| 444/265| 1903/745| 16|
1/4| 5-15P
F18SC52B| (2) 19”| 70| 7.15| 8| 115/60/1| 10.0| 444/353| 1903/867| 16|
1/4| 5-15P
F18SC52C| (2) 19”| 70| 7.15| 10| 115/60/1| 10.0| 444/441| 1903/971| 16|
1/4| 5-15P
F18SC52D| (2) 19”| 70| 7.15| 12| 115/60/1| 10.0| 444/529| 1903/1061| 16|
1/4| 5-15P
F18SC60A| (1) 19” & (1) 27”| 70/124| 8.97| 6| 115/60/1| 10.0| 515/265|
2314/667| 16| 1/4| 5-15P
F18SC60B| (1) 19” & (1) 27”| 70/124| 8.97| 8| 115/60/1| 10.0| 515/353|
2314/798| 16| 1/4| 5-15P
F18SC60C| (1) 19” & (1) 27”| 70/124| 8.97| 10| 115/60/1| 10.0| 515/441|
2314/916| 16| 1/4| 5-15P
F18SC60D| (1) 19” & (1) 27”| 70/124| 8.97| 12| 115/60/1| 10.0| 515/529|
2314/1023| 16| 1/4| 5-15P
Remote Refrigerated Reduced Height Rail
Model| # Of Doors| Shelf Max Load (lbs)| Base Volume
FT³| Shelf Area FT²| # of Pans| Volts/Hertz/
Phase| Amps| BTU Load Base/Rail| Evap. BTU/°TD
Base/Rail
---|---|---|---|---|---|---|---|---|---
F18DR44| (2) 19”| 70| 9.54| 5.12| 10| 115/60/1| 3.0| 547/441|
120/5°/19/23°
F18DR52| (1) 19” & (1) 27”| 70/124| 13.89| 6.51| 12| 115/60/1| 3.0|
625/529| 120/5°/23/23°
F18DR60| (2) 27”| 124| 16.64| 7.9| 16| 115/60/1| 5.0| 703/617|
120/6°/26/24°
F18DR70| (2) 32”| 140| 22.96| 9.64| 18| 115/60/1| 5.0| 800/794|
120/7°/32/24°
F18DR79| (1) 19” & (2) 27”| 70/124| 22.47| 10.29| 18| 115/60/1| 5.0|
962/882| 240/4°/36/25°
F18DR87| (3) 27”| 124| 25.22| 11.85| 22| 115/60/1| 5.0| 1032/970|
240/4°/39/25°
Self-Contained Refrigerated Reduced Height Rail
Model| # Of Doors| Shelf Max Load (lbs)
| Base Volume FT³
| Shelf Area FT²| # of Pans| Volts/Hertz/
Phase| Amps| BTU Load Base/Rail| BTU System Cap.
Base/Rail| R- 04A
oz.| H.P.| NEMA Plug
---|---|---|---|---|---|---|---|---|---|---|---|---
F18DC52| (2) 19”| 70| 9.54| 5.12| 12| 115/60/1| 10.0| 547/529|
1903/1061| 16| 1/4| 5-15P
F18DC60| (1) 19” & (1) 27”| 70/124| 13.89| 6.51| 14| 115/60/1| 12.0|
625/617| 2314/1121| 24| 1/3| 5-15P
F18DC68| (2) 27”| 124| 16.64| 7.9| 18| 115/60/1| 12.0| 703/794|
2314/1544| 24| 1/3| 5-15P
F18DC82| (2) 32”| 140| 22.96| 9.64| 20| 115/60/1| 14.0| 800/882|
3097/1648| 32| 1/2| 5-20P
F18DC91| (1) 19” & (2) 27”| 70/124| 22.47| 10.29| 22| 115/60/1| 14.0|
962/1058| 3807/1839| 32| 1/2| 5-20P
F18DC99| (3) 27”| 124| 25.22| 11.85| 24| 115/60/1| 14.0| 1032/1147|
3807/1839| 32| 1/2| 5-20P
Remote Refrigerated Reduced Height Rail
Model| # Of Doors| Shelf Max Load (lbs)| Base Volume
FT³| Shelf Area FT²| Volts/Hertz/ Phase| Amps|
BTU Load Base/Rail| Evap. BTU/°TD Base/Rail| #
of Pans
---|---|---|---|---|---|---|---|---|---
F18RR44| (2) 19”| 70| 9.49| 5.12| 115/60/1| 3.0| 547/441| 120/5°/19/23°|
10
F18RR52| (1) 19” & (1) 27”| 70/124| 11.81| 6.51| 115/60/1| 3.0| 625/529|
120/5°/23/23°| 12
F18RR60| (2) 27”| 124| 14.14| 7.9| 115/60/1| 5.0| 703/617|
120/6°/26/24°| 16
F18RR70| (2) 32”| 140| 17.05| 9.64| 115/60/1| 5.0| 800/794|
120/7°/32/24°| 18
F18RR79| (1) 19” & (2) 27”| 70/124| 18.68| 10.29| 115/60/1| 5.0|
962/882| 240/4°/36/25°| 18
F18RR87| (3) 27”| 124| 21.30| 11.85| 115/60/1| 5.0| 1032/970|
240/4°/39/25°| 22
Self-Contained Refrigerated Reduced Height Rail
Model| # Of Doors| Shelf Max Load (lbs)
| Base Volume FT³
| Shelf Area FT²| Volts/Hertz/ Phase| Amps|
BTU Load Base/Rail| BTU System Cap. Base/Rail| # of
Pans| R-404A oz.| H.P.| NEMA Plug
---|---|---|---|---|---|---|---|---|---|---|---|---
F18RC52| (2) 19”| 70| 9.49| 5.12| 115/60/1| 10.0| 547/529| 1903/1061|
12| 16| 1/4| 5-15P
F18RC60| (1) 19” & (1) 27”| 70/124| 11.81| 6.51| 115/60/1| 12.0|
625/617| 2314/1121| 14| 24| 1/3| 5-15P
F18RC68| (2) 27”| 124| 14.14| 7.9| 115/60/1| 12.0| 703/794| 2314/1544|
16| 24| 1/3| 5-15P
F18RC82| (2) 32”| 140| 17.05| 9.64| 115/60/1| 14.0| 800/882| 3097/1648|
20| 32| 1/2| 5-20P
F18RC91| (1) 19” & (2) 27”| 70/124| 18.68| 10.29| 115/60/1| 14.0|
962/1058| 3807/1839| 22| 32| 1/2| 5-20P
F18RC99| (3) 27”| 124| 21.30| 11.85| 115/60/1| 14.0| 1032/1147|
3807/1839| 24| 32| 1/2| 5-20P
Remote Freezer Base
Model| # Of Doors| Shelf Max Load (lbs)| Base Volume
FT³| Shelf Area FT²| Volts/Hertz/ Phase| Amps|
BTU Load Base/Rail| Evap. BTU/°TD
---|---|---|---|---|---|---|---|---
F18FR35| (1) 19”| 70| 5.58| 2.56| 115/60/1| 10.0| 943| 160/6°
F18FR50| (2) 19”| 70| 12.21| 5.12| 115/60/1| 10.0| 1471| 160/9°
F18FR58| (1) 19” & (1) 27”| 70/124| 15.00| 6.51| 115/60/1| 10.0| 1844|
160/10°
F18FR66| (2) 27”| 124| 17.79| 7.9| 115/60/1| 10.0| 2020| 160/11°
F18FR76| (2) 32”| 140| 21.28| 9.64| 115/60/1| 10.0| 2437| 160/13°
Self-Contained Freezer Base
Model| # Of Doors| Shelf Max Load (lbs)
| Base Volume FT³
| Shelf Area FT²| Volts/Hertz/ Phase| Amps|
BTU Load Base/Rail| BTU System Cap. Base/Rail| H.P.|
R-404A
oz.| NEMA Plug
---|---|---|---|---|---|---|---|---|---|---|---
F18FC43| (1) 19”| 70| 5.58| 2.56| 115/60/1| 10.0| 943| 1558| 1/3| 24|
5-15P
F18FC62| (2) 19”| 70| 12.21| 5.12| 115/60/1| 12.0| 1471| 1776| 1/2| 40|
5-15P
F18FC70| (1) 19” & (1) 27”| 70/124| 15.00| 6.51| 115/60/1| 16.0| 1647|
2713| 3/4| 56| 5-20P
F18FC78| (2) 27”| 124| 17.79| 7.9| 115/60/1| 16.0| 1824| 2713| 3/4| 56|
5-20P
F18FC88| (2) 32”| 140| 21.28| 9.64| 115/60/1| 16.0| 2045| 2713| 3/4| 56|
5-20P
Self-Contained Dual Rails
Model| # Of Doors| Shelf Max Load (lbs)
| Base Volume FT³
| Shelf Area FT²| Volts/Hertz/ Phase| Amps|
BTU Load Base/Rail| BTU System Cap. Base/Rail| H.P.|
R-404A
oz.| NEMA
Plug
---|---|---|---|---|---|---|---|---|---|---|---
F18PD48| (1) 27”| 124| 9.38| 3.95| 115/60/1| 10.0| 424/1058| 2001/1865|
1/5, 1/3| 40| 5-20P
F18PD72| (2) 27”| 124| 16.64| 7.90| 115/60/1| 12.7| 703/1588| 2001/3174|
1/5. 1/2| 48| 5-20P
Installation
Location
These units are intended for indoor use only. Be sure the location chosen has
a floor strong enough to support the total weight of the cabinet and contents.
A fully loaded 72” (183cm) long model may weigh as much as 1500 pounds
(680kg)! Reinforce the floor as necessary to provide for maximum loading.
It is very important to allow for proper air flow, both inside and outside.
Avoid hot corners and locations near stoves, ovens and other pieces of cooking
equipment.
It is recommended that the unit be installed nocloser than 1” (2.54cm) from
any wall. Do notinstall the unit near any combustible material orobject
affected by heat or moisture.
PDL models also require 14″ (36cm) clearanceat the top and 6″ (15cm) clearance
at the bottom(casters).
Leveling
A level cabinet looks better and will perform better because the drain pan
will drain properly, the doors will line up with the frames properly, and the
cabinet will not be subject to undue strain.
A unit on legs will have an adjustable bullet foot on each leg, adjust each
for a level unit. A unit on casters will not be adjustable. Be sure the unit
is on a level floor, make necessary changes to the floor for proper level.
Lock all front casters to ensure the stability of the unit.
Plumbing
Self-contained models are standard with a condensate evaporator.
If, for some reason a unit does not have a condensate evaporator, or if the
evaporator fails, the unit’s drain must have an outlet to an appropriate
drainage area or container. A refrigerated rail will have a 1″ (2.54cm) drain
which will need to be run to an appropriate floor drain or container. The
drain will be stubbed to the bottom of the machine compartment. Either run
drain to a floor drain or add a valve to the base of the machine compartment
and drain the rail to a container when convenient.
The LiquiTec option will NOT have a drain available.
Moisture collecting from improper drainage can create a slippery surface on
the floor and a hazard to employees. It is the owner’s responsibility to
provide a container or outlet for drainage.
Electrical connection
Refer to the specification pages amperage data, the serial tag, your local
code or the National Electrical Code to be sure the unit is connected to the
proper power source. A protected circuit of the correct voltage and amperage
must be run for connection of the line cord, or permanent connection of the
unit.
Self-contained units with a cord and plug have an ON/OFF switch located
directly behind the louvered panel covering the compressor section. Simply
turn the switch to ON to begin operation.
The power switch must be turned to OFF and the unit disconnected from the
power source whenever performing service or maintenance functions.
Never operate the unit without the louvered panel in place!
If electrical receptacles are to be mounted in the unit’s backsplash, they
must be wired independently from the existing unit wiring.
Refrigerator Operation
Power up the unit by turning ON the unit’s ON/OFF switch.
Delfield refrigerated bases are designed to maintain anoperational temperature
of 36°F to 40°F (2°C to 4°C).Temperature in the salad top and refrigerated
rail opening is 33°F to 41°F (0°C to 5°C) with pans recessed 2” (5.1cm) on a
standard wrapped refrigerated rail or flush with the LiquiTec option at 86°F
(30°C) ambient room temperature.
Do not place hot pans on/against the blue ABS liner.
Do not throw items into the storage area. Failure to heed these
recommendations could result in damage to the interior of the cabinet or to
the blower coil.
Overloading the storage area, restricting the air flow, and continuous opening
and closing of the doors and drawers will hamper the units ability to maintain
operational temperature.
Refrigerated rail units
Product in the rail should be removed to the refrigerated base at the end of
the day. This allows you to turn the rail off at night to save energy and the
rail will have time to defrost as needed.
It also helps maintain product quality. The standard wrapped refrigerated
units are controlled by the pressure control which is set to maintain the
proper rail temperature. An on/off switch is also provided for the rail and is
required to be shut off at night. The rail switch shuts off the rail only.
With a LiquiTec rail a thermostat is provided to maintain rail temperature as
well as the rail on/off switch. The LiquiTec rail is required to be shut off
at night as well to allow for defrosting. To ensure product quality in the
rail it is recommended that product be rotated every four hours.
If adding any item to the unit, be sure to keep in mind the location of the
refrigeration lines on wrapped rail units. A refrigeration leak in a rail is
extremely difficult and costly to repair. In some cases it cannot be repaired
at all.
Refrigerator Evaporator Fan Operation
When the refrigerator is initially powered up or immediately following a
power outage the unit will begin cooling after a 3-6 minute delay. During
normal operation the evaporator fan pulses independently of the compressor as
dictated by the controller as follows:
- During the cooling mode, compressor and evaporator fan run simultaneously.
- During the compressor off mode, evaporator fan pulses three minutes on and three minutes off.
- During an actual defrost event other than the off-cycle defrost, compressor stays off but the evaporator fan runs continuously.
Cooling Cycle | Defrost Cycle |
---|---|
Compressor On | Compressor Off |
Evap Fan On | Evap Fan Off |
Off
X| | Cycles On 3-Min, Off 3-Min| X|
Freezer Operation
Power up the unit by turning ON the unit’s ON/OFFswitch.
Delfield freezer bases are designed to maintain an operational temperature of
0°F (-18°C).
Do not place hot pans on/against the blue ABS liner.
Do not throw items into the storage area. Failure to heed these
recommendations could result in damage to the interior of the cabinet or to
the blower coil.
Overloading the storage area, restricting the air flow, and continuous opening
and closing of the doors and drawers will hamper the units ability to maintain
operational temperature.
Freezer Evaporator Fan Operation
The evaporator fan(s) and condenser fan will cycle off and on with the
compressor to conserve energy. The temperature control will cycle the
compressor and condenser fan motor and evaporator fan motor to maintain box
temperature at the control setting.
Cooling Cycle | Defrost Cycle |
---|---|
All Freezers | Self-Contained Freezers |
Compressor On | Compressor Off |
Evap Fan On | Evap Fan Off |
Freezer Defrost
Self-contained models use hot gas to defrost the evaporator coils.
Remote freezers use electric defrost.
Temperature Control Settings
A thermostat controls temperature in the self-contained F18WC, F18FC, F18MC
base, F18SC base, F18RC base, F18DC base, F18PD base and F18PD rails.
Thermostats are located in the machine compartment. They are field adjustable
and do not require a service agent. The factory setting is 2.5. Set toward 1
for higher temperatures and toward 7 for lower temperatures.
A thermostat controls temperature in the remote F18FR. The temperature control
is located in the machine compartment.
It is field adjustable and does not require a service agent.
The factory setting for a remote freezer is 0°F cut-in with a 5°F
differential.
Please make small incremental adjustments if a temperature adjustment is
necessary. It may take an hour or longer to realize the temperature change
depending on the application and location of the unit.
Contact the service department at Delfield +1
989-773-7981 or your local service
agent for additional assistance. Delfield is not responsible for charges
incurred while adjusting the thermostat.
Pressure Control Settings
A pressure control controls temperature in the F18MC mega top, F18SC salad
top, F18RC rail and F18DC rail.
The factory recommended low-pressure control settings are: 55psi cut-in and
30psi cut-out to maintain proper temperature for product. The interior
temperature is controlled by the thermostat mounted in the mechanical
compartment.
A pressure control is located in the machine compartment.
An adjustable control has the word COLDER on the knob, with an arrow to
indicate the adjustment direction. These controls are field adjustable and do
not require a service agent.
In attempting to adjust the pressure control, you can do damage to your unit
by accidentally adjusting the differential. Please make small incremental
adjustments if a temperature adjustment is necessary. It may take an hour or
longer to realize the temperature change depending on the application and
location of the unit.
Please contact the service department at Delfield
800-733-8829 or your local service
agent.
Delfield is not responsible for charges incurred while having the pressure
control adjusted.
Maintenance
Door Gasket Maintenance
Door gaskets require regular cleaning to prevent mold and mildew build up and
also to retain the elasticity of the gasket. Gasket cleaning can be done with
the use of warm soapy water. Avoid full strength cleaning products on gaskets
as this can cause them to become brittle and crack. Never use sharp tools or
knives to scrape or clean the gasket. Gaskets can be easily replaced and do
not require the use of tools or an authorized service person. The gaskets are
“Dart” style and can be pulled out of the groove in the door and new gaskets
can be “pressed” back into place.
Drain Maintenance – Base
Each unit has a drain located inside the unit that removes the condensation
from the evaporator coil and routes it to an external condensate evaporator
pan. Each drain can become loose or disconnected during normal use. If you
notice water accumulation on the inside of the unit be sure the drain tube is
connected to the evaporator drain pan. If water is collecting underneath the
unit make sure the end of the drain tube is in the condensate evaporator in
the machine compartment. The leveling of the unit is important as the units
are designed to drain properly when level. Be sure all drain lines are free of
obstructions.
Drawer Maintenance
Drawer Assembly Cleaning
The drawer assembly is designed to be cleaned easily. Both drawer and tracks
are removable without tools. The drawer tracks are dishwasher safe or can be
cleaned in a sink with detergents and a soft bristle brush. Drawers and tracks
should be cleaned on a weekly basis.
Remove Drawers
Pull the drawer box out until it stops. Lift up on the drawer front and
pull the drawer box completely out. Using a soft bristle brush, clean the
track on the bottom of the drawer box. When finished, it should be wiped clean
of all food and debris.
Tracks
The drawer box assembly must be removed. Pull the drawer tracks out until
they hit a stop. Locate blue safety clips towards the back of each drawer
track. Blue safety clips have a tab on the top. Push the tab back until it
clicks. Lift up and pull the drawer tracks all the way out of the drawer cage.
The drawer tracks are dishwasher safe or can be cleaned in a sink with
detergents and a soft bristle brush. Drawers and tracks should be cleaned on a
weekly basis. Using a soft bristle brush, wash the track making sure each
roller is thoroughly cleaned. The drawer cage should be cleaned with a soft
bristle brush, removing any food and debris gathered on the bottom ledge. Once
it’s cleaned thoroughly with a soft bristle brush, wipe remaining debris clean
with a soft towel. Reassembly
Push the drawer tracks into the drawer cage. The blue safety clip must
remain pushed towards the back. Lift up and slide the drawer track all the way
into the drawer cage. The blue safety clip will lock in place automatically.
Once all tracks are replaced, insert the drawer box. Rest the drawer box
bottom track on the front track roller. Then push the drawer back in place
SLOWLY. When the drawer box is about half way in you will hit a STOP. You must
lift the front of the drawer up approximately ½” (1.3cm) to continue inward.
Clean tracks as often as possible. The cleaner the tracks are the better they
will operate.
Caster Maintenance
Wipe casters with a damp cloth monthly to prevent corrosion.
The power switch must be turned to OFF and the unit disconnected from the
power source whenever performing service, maintenance functions or cleaning
the refrigerated area.
Refrigerators and Freezers
The interior and exterior can be cleaned using soap and warm water.
If this isn’t sufficient, try ammonia and water or a nonabrasive liquid
cleaner. When cleaning the exterior, always rub with the “grain” of the
stainless steel to avoid marring the finish. Do not use an abrasive cleaner
because it will scratch the stainless steel and can damage the breaker strips
and gaskets.
Stainless Steel Care and Cleaning
To prevent discoloration of rust on stainless steel several important steps
need to be taken. First, we need to understand the properties of stainless
steel. Stainless steel contains 70- 80% iron, which will rust. It also
contains 12-30% chromium, which forms an invisible passive film over the
steels surface, which acts as a shield against corrosion. As long as the
protective layer is intact, the metal is still stainless. If the film is
broken or contaminated, outside elements can begin to breakdown the steel and
begin to form discoloration of rust. Proper cleaning of stainless steel
requires soft cloths or plastic scouring pads.
NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS!
Cleaning solutions need to be alkaline based or non-chloride cleaners.
Any cleaner containing chlorides will damage the protective film of the
stainless steel. Chlorides are also commonly found in hard water, salts, and
household and industrial cleaners. If cleaners containing chlorides are used
be sure to rinse repeatedly and dry thoroughly. Routine cleaning of stainless
steel can be done with soap and water.
Extreme stains or grease should be cleaned with a non-abrasive cleaner and
plastic scrub pad. Always rub with the grain of the steel. There are stainless
steel cleaners available which can restore and preserve the finish of the
steels protective layer. Early signs of stainless steel breakdown are small
pits and cracks. If this has begun, clean thoroughly and start to apply
stainless steel cleaners in attempt to restore the passivity of the steel.
Never use an acid based cleaning solution! Many food products have an acidic
content, which can deteriorate the finish. Be sure to clean the stainless
steel surfaces of ALL food products. Common items include, tomatoes, peppers
and other vegetables.
Cleaning the Condenser Coil
In order to maintain proper refrigeration performance, thecondenser fins
must be cleaned of dust, dirt and grease regularly.
It is recommended that this be done at least every three months.
If conditions are such that the condenser is totally blocked in three months,
the frequency of cleaning should be increased. Clean the condenser with a
vacuum cleaner or stiff brush. If extremely dirty, a commercially available
condenser cleaner may be required.
Failure to maintain a clean condenser coil can initially cause high
temperatures and excessive run times. Continuous operation with a dirty or
clogged condenser coil can result in compressor failure.
Neglecting the condenser coil cleaning procedures will void any warranties
associated with the compressor and cost to replace the compressor.
Never use a high-pressure water wash for this cleaning procedure as water can
damage the electrical components located near or at the condenser coil.
Doors/Hinges
Over time and with heavy use doors the hinges may become loose. If this
happens tighten the screws that mount the hinge brackets to the frame of the
unit. Loose or sagging doors can cause the hinges to pull out of the frame,
which may damage both the doors and the hinges. In some cases this may require
qualified service agents or maintenance personnel to perform repairs.
Do not place hot pans on/against the blue ABS liner.
Do not throw items into the storage area. Failure to follow these
recommendations could result in damage to the interior of the cabinet or to
the blower coil.
Overloading the storage area, restricting the airflow, and continuous opening
and closing of the doors and drawers will hamper the units ability to maintain
operational temperature.
Refrigerated rail units
Product in the rail should be removed to the refrigerated base at the end of
the day. This allows you to turn the rail off at night to save energy and to
defrost the rail. It also helps maintain product quality.
The standard wrapped refrigerated rail units are controlled by a lowpressure
control that is set to maintain the proper rail temperature.
An on/off switch is also provided for the rail and is required to be shut off
at night. With a LiquiTec rail a thermostat is provided to maintain rail
temperature as well as the rail on/off switch. The LiquiTec rail is required
to be shut off at night as well to allow for defrosting. To ensure product
quality in the rail it is recommended that product be rotated every four
hours.
If adding any item to the unit, be sure to keep in mind the location of the
refrigeration lines on wrapped rail units. A refrigeration leak in a rail is
extremely difficult and costly to repair. In some cases it cannot be repaired
at all.
Preventing blower coil corrosion
To help prevent corrosion of the blower coil, store all acidic items, such as
pickles and tomatoes, in sealable containers. Immediately wipe up all spills.
Units with pans should be operated with pans in place.
Operating the unit without all pans in place will lower efficiency and may
damage the unit.
Continuous opening and closing of the doors will hamper the unit’s ability to
maintain optimum refrigeration temperature. Top section is not intended for
overnight storage. Product should be removed from pans. Pans can remain in
unit while empty.
Wiring Diagrams
Wiring Diagram, F18WC
![Delfield F18MC52D Refrigerated Work Tables Salad Tables and Freezer Bases
- Wiring Diagram](https://manuals.plus/wp-content/uploads/2024/02/Delfield-
F18MC52D-Refrigerated-Work-Tables-Salad-Tables-and-Freezer-Bases-Wiring-
Diagram.png) Wiring Diagram, F18WR
![Delfield F18MC52D Refrigerated Work Tables Salad Tables and Freezer Bases - Wiring Diagram 2](https://manuals.plus/wp-content/uploads/2024/02/Delfield-
F18MC52D-Refrigerated-Work-Tables-Salad-Tables-and-Freezer-Bases-Wiring-
Diagram-2.png) Wiring Diagram, F18MC, F18SC, F18DC & F18RC
Wiring Diagram, F18MR, F18SR, F18DR & F18RR
![Delfield F18MC52D Refrigerated Work Tables Salad Tables and Freezer Bases - Wiring Diagram 4](https://manuals.plus/wp-content/uploads/2024/02/Delfield-
F18MC52D-Refrigerated-Work-Tables-Salad-Tables-and-Freezer-Bases-Wiring-
Diagram-4.png) Wiring Diagram, F18FC
Wiring Diagram, F18FR Wiring Diagram, F18PD
Replacement Parts
F18DC
3516053| Coil, solenoid, 120V/50/60HZ (rail)
---|---
*000-248-0030| Coil assembly, R404A
*000-BN5-0035| Condensing unit, 1/2hp, R404a
*000-BN5-0037| Condensing unit, 1/3hp, R404a
*000-BN5-0030| Condensing unit, 1/4hp, R404a
2194824| Control, Danfoss, GDM, 115V
2193927| Control, pressure, low
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
160179| Hinge Kit
3234645| Leg, 6″, s/s
3977984| Shelf, 19″ door
3977998| Shelf, 24″ door
3978014| Shelf, 27″ door
3977983| Shelf, 32″ door
2190154| Switch, rocker
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
3234290| Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
F18DR
3516053| Coil, solenoid, 120V/50/60HZ (rail)
---|---
*000-248-0030| Coil assembly, R404A
*000-248-0037| Coil assembly, R404A, Fan Lt
2194824| Control, Danfoss, GDM, 115V
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
160179| Hinge Kit (left or right hinged)
3234645| Leg, 6″, s/s
3977984| Shelf, 19″ door
3977998| Shelf, 24″ door
3978014| Shelf, 27″ door
3977983| Shelf, 32″ door
3234290| Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
2190154| Switch, rocker
2194201| Thermostat, rail
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18FC
*000-BN5-0053 | Condensing unit, 1/3HP, w/rec, hg |
---|---|
*000-BN5-0054 | Condensing unit, 1/2HP, low temp, hg |
*000-BN5-0055 | Condensing unit, 3/4HP, low temp, hg |
*000-249-0004 | Coil, assembly, freezer, R404a |
2194758-4| Control, Danfoss, Freezer, 115V
160179| Hinge Kit
3234645| Leg, 6″, s/s
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
3234290| Shelf support, 1″ blue
3977984| Shelf, 19″ door
3977998| Shelf, 24″ door
3978014| Shelf, 27″ door
3977983| Shelf, 32″ door
2190154| Switch, rocker
F18FR
*000-249-0006 | Coil assembly, frz evap, remote |
---|
3516053| Coil, solenoid, 120V/50/60HZ
3516056| Control, Temperature
160179| Hinge Kit
3234645| Leg, 6″, s/s
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
3234290| Shelf support, 1″ blue
3977984| Shelf, 19″ door
3977998| Shelf, 24″ door
3978014| Shelf, 27″ door
3977983| Shelf, 32″ door
2194151| Timer, Paragon, #8145-00
3516102| Valve, solenoid
F18MC
030-209-0030 | Angle, Coil, Top Baffle |
---|
3516053| Coil, solenoid, 120V/50/60HZ (rail)
*000-248-0030| Coil assembly, R404A
000-248-0037| Coil assembly, R404A, Fan Lt
[000-BN5-0030](http://www.partstown.com/delfield/del000-bn5-0030?pt-manual
=DEL-F18_spm.pdf)| Condensing unit, 1/4hp, R404a
2194824| Control, Danfoss, GDM, 115V
2193927| Control, pressure, low
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
420068| Hinge kit, lo profile (left or right)
2190154| Switch, rocker
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
3234645| Leg, 6″, s/s
F18MR
030-209-0030 | Angle, Coil, Top Baffle |
---|
3516053| Coil, solenoid, 120V/50/60HZ (rail)
*000-248-0030| Coil assembly, R404A
*000-248-0037| Coil assembly, R404A, Fan Lt
2194824| Control, Danfoss, GDM, 115V
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
420068| Hinge kit, lo profile (left or right)
3234645| Leg, 6″, s/s
9321041| Nut, acorn (for pan cover)
2190154| Switch, rocker
2194201| Thermostat, rail
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18PD48
*000-248-0037 | Coil assembly, R404A, Fan Lt |
---|---|
*000-BN5-0040 | Condensing Assembly, 1/3-1/5 Stacked |
2194824| Control, Danfoss, GDM, 115V
2194938| Control, Tstat, Danfoss, Etc1h-1
000-402-0056| Cover Assembly, hinged, 6 pan, l/t
[000-187-006B](http://www.partstown.com/delfield/del000-187-006b?pt-manual
=DEL-F18_spm.pdf)| Door Assembly, ref, 27×26, lt
3234645| Leg, 6, s/s, removable Foot
*356-478-0038| Panel, louver, 14.0, sw Cut, lh
3978014| Shelf, wire, coated
3234290| Support, shelf, plastic
2190154| Switch, rocker, 20a/125v
3516135| Thermometer, hanging, 4
F18PD72
*000-248-0030| Coil assembly, R404A
---|---
000-BN5-003Y| Condensing Assembly, 1/2-1/5 Stacked
2194824| Control, Danfoss, GDM, 115V
2194938| Control, Tstat, Danfoss, Etc1h-1
000-402-0056| Cover Assembly, hinged, 6pan, l/t
*000-187-006B| Door Assembly, ref, 27×26, lt
*000-187-006A| Door Assembly, ref, 27×26, rt
3234645| Leg, 6, s/s, removable Foot
*356-478-0039| Panel, louver, 18.0, sw Cut, lh
3978014| Shelf, wire, coated
3234290| Support, shelf, plastic
2190154| Switch, rocker, 20a/125v
3516135| Thermometer, hanging, 4
F18RC
3516053| Coil, solenoid, 120V/50/60HZ (rail)
---|---
*000-248-0030| Coil assembly, R404A
*000-BN5-0035| Condensing unit, 1/2hp, R404a
*000-BN5-0037| Condensing unit, 1/3hp, R404a
*000-BN5-0030| Condensing unit, 1/4hp, R404a
2194824| Control, Danfoss, GDM, 115V
2193927| Control, pressure, low
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
160179| Hinge Kit
3234645| Leg, 6″, s/s
3977984| Shelf, 19″ door
3977998| Shelf, 24″ door
3978014| Shelf, 27″ door
3977983| Shelf, 32″ door
3234290| Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
2190154| Switch, rocker
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18RR
3516053| Coil, solenoid, 120V/50/60HZ (rail)
---|---
*000-248-0030| Coil assembly, R404A
*000-248-0037| Coil assembly, R404A, Fan Lt
2194824| Control, Danfoss, GDM, 115V
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
160179| Hinge Kit
3234645| Leg, 6″, s/s
3977984| Shelf, 19″ door
3977998| Shelf, 24″ door
3978014| Shelf, 27″ door
3977983| Shelf, 32″ door
3234290| Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
2190154| Switch, rocker
2194201| Thermostat, rail
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18SC
030-209-0030 | Angle, Coil, Top Baffle |
---|
3516053| Coil, solenoid, 120V/50/60HZ (rail)
*000-248-0030| Coil assembly, R404A
000-248-0037| Coil assembly, R404A, Fan Lt
[000-BN5-0030](http://www.partstown.com/delfield/del000-bn5-0030?pt-manual
=DEL-F18_spm.pdf)| Condensing unit, 1/4hp, R404a
2194824| Control, Danfoss, GDM, 115V
2193927| Control, pressure, low
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
420068| Hinge kit, lo profile (left or right)
3234645| Leg, 6″, s/s
2190154| Switch, rocker
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18SR
030-209-0030 | Angle, Coil, Top Baffle |
---|
3516053| Coil, solenoid, 120V/50/60HZ (rail)
*000-248-0030| Coil assembly, R404A
*000-248-0037| Coil assembly, R404A, Fan Lt
2194824| Control, Danfoss, GDM, 115V
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
420068| Hinge kit, lo profile (left or right)
3234645| Leg, 6″, s/s
2190154| Switch, rocker
2194201| Thermostat, rail
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18WC
*000-248-0030| Coil assembly, R404A
---|---
000-248-0037| Coil assembly, R404A, Fan Lt
[000-BN5-0030](http://www.partstown.com/delfield/del000-bn5-0030?pt-manual
=DEL-F18_spm.pdf)| Condensing unit, 1/4hp, R404a
*000-BN5-0031| Condensing unit, 1/5hp, R404a
2194810| Control, Danfoss, GDM, 115V
160179| Hinge Kit
3234645| Leg, 6″, s/s
3977984| Shelf, 19″ door
3977998| Shelf, 24″ door
3978014| Shelf, 27″ door
3977983| Shelf, 32″ door
2190154| Switch, rocker
3234290| Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
F18WR
*000-248-0030| Coil assembly, R404A
---|---
*000-248-0037| Coil assembly, R404A, Fan Lt
2194810| Control, Danfoss, GDM, 115V
160179| Hinge Kit (left or right hinged)
3234645| Leg, 6″, s/s
3977984| Shelf, 19″ door
3977998| Shelf, 24″ door
3978014| Shelf, 27″ door
3977983| Shelf, 32″ door
3234290| Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
Replacement Part Assemblies
Key | Part Number | Description |
---|---|---|
– | 000-249-0004 | Coil Assembly, Evap, Freezer |
1 | 030-262-0001 | Side, evaporator |
2 | [2160023](http://www.partstown.com/delfield/del2160023?pt-manual=DEL- | |
F18_spm.pdf) | Fan, axiel | |
3 | [2160024](http://www.partstown.com/delfield/del2160024?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan, 4.7″, SC120-W2 | |
4 | 030-260-0001 | Top, frz, evaporator |
5 | 030-259-0000 | Front, enclosure |
6 | [3516271](http://www.partstown.com/delfield/del3516271?pt-manual=DEL- | |
F18_spm.pdf) | Valve, expansion, R404a | |
7 | 265-261-0001 | Pan, freezer |
evaporator
8| 3516073| Coil, Evaporator
9| 030-263-0001| Back, evaporator
–| 2184318| Harness, coil, frz, male
–| 2194808| Probe, Defrost, Danfoss, Control
–| 2194809| Probe, Temp, Sensor, Danfoss
Key | Part Number | Description |
---|---|---|
– | 000-249-0006 | Coil Assembly, Freezer Evap, Remote |
1 | 030-262-0001 | Side, evaporator |
2 | [2160023](http://www.partstown.com/delfield/del2160023?pt-manual=DEL- | |
F18_spm.pdf) | Fan, axiel | |
3 | [2160024](http://www.partstown.com/delfield/del2160024?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan, 4.7″, SC120-W2 | |
4 | 030-260-0001 | Top, frz, evaporator |
5 | 030-259-0000 | Front, enclosure |
6 | [3516271](http://www.partstown.com/delfield/del3516271?pt-manual=DEL- | |
F18_spm.pdf) | Valve, expansion, R404a | |
7 | [3516073](http://www.partstown.com/delfield/del3516073?pt-manual=DEL- | |
F18_spm.pdf) | Coil, Evaporator | |
8 | [2194034](http://www.partstown.com/delfield/del2194034?pt-manual=DEL- | |
F18_spm.pdf) | Heater, Defrost | |
9 | 265-261-0001 | Pan, freezer |
evaporator
10| 030-263-0001| Back, evaporator
–| 2194046| Control, Limit, Fan Delay/Defrost
–| 2194631| Fuse, Defrost Heater, 7 Amp
–| 2184323| Harness, coil, frz, male, remote
Key | Part Number | Description |
---|---|---|
– | [ 000-248-0030](http://www.partstown.com/delfield/del000-248-0030 | |
?pt-manual=DEL-F18_spm.pdf) | Coil Assembly, R404A, Ref | |
1 | [2160024](http://www.partstown.com/delfield/del2160024?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan, 4.7″ | |
2 | [2160023](http://www.partstown.com/delfield/del2160023?pt-manual=DEL- | |
F18_spm.pdf) | Fan, axiel, 120V | |
3 | [3516095](http://www.partstown.com/delfield/del3516095?pt-manual=DEL- | |
F18_spm.pdf) | Coil, evaporator | |
4 | 030-232-0003 | Back, evaporator, enclosure |
5 | [3516273](http://www.partstown.com/delfield/del3516273?pt-manual=DEL- | |
F18_spm.pdf) | Expansion valve, 1/4, R-404a | |
6 | 030-233-0001 | Side, coil, angled |
7 | 075-231-0033 | Drip pan, evaporator |
8 | 030-234-0003 | Front, coil |
– | [2184317](http://www.partstown.com/delfield/del2184317?pt-manual=DEL- | |
F18_spm.pdf) | Harness, coil | |
– | [2194808](http://www.partstown.com/delfield/del2194808?pt-manual=DEL- | |
F18_spm.pdf) | Probe, Defrost, Danfoss, Control | |
– | [2194809](http://www.partstown.com/delfield/del2194809?pt-manual=DEL- | |
F18_spm.pdf) | Probe, Temp, Sensor, Danfoss |
Key | Part Number | Description |
---|---|---|
– | 000-248-0037 | Coil Assembly, R404A, Ref, Fan Lt |
1 | [2160024](http://www.partstown.com/delfield/del2160024?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan, 4.7″ | |
2 | [2160023](http://www.partstown.com/delfield/del2160023?pt-manual=DEL- | |
F18_spm.pdf) | Fan, axiel, 120V | |
3 | [3516095](http://www.partstown.com/delfield/del3516095?pt-manual=DEL- | |
F18_spm.pdf) | Coil, evaporator | |
4 | 030-232-0003 | Back, evaporator, enclosure |
5 | [000-BNH-0030](http://www.partstown.com/delfield/del000-bnh-0030?pt-manual | |
=DEL-F18_spm.pdf) | Drip pan, evaporator | |
6 | 030-233-0038 | Side, coil, angled, Rt, Blank |
7 | [3516273](http://www.partstown.com/delfield/del3516273?pt-manual=DEL- | |
F18_spm.pdf) | Expansion valve, 1/4, R-404a | |
8 | 030-234-0003 | Front, coil |
9 | 030-233-0039 | Side, Coil, Angled, Lt, 2Fan |
– | [2184317](http://www.partstown.com/delfield/del2184317?pt-manual=DEL- | |
F18_spm.pdf) | Harness, coil | |
– | [2194808](http://www.partstown.com/delfield/del2194808?pt-manual=DEL- | |
F18_spm.pdf) | Probe, Defrost, Danfoss, Control | |
– | [2194809](http://www.partstown.com/delfield/del2194809?pt-manual=DEL- | |
F18_spm.pdf) | Probe, Temp, Sensor, Danfoss |
Key | Part Number | Description |
---|---|---|
– | [ 000-BN5-0030](http://www.partstown.com/delfield/del000-bn5-0030 | |
?pt-manual=DEL-F18_spm.pdf) | Assembly, 1/4 HP Condensing Unit | |
1 | [2160028](http://www.partstown.com/delfield/del2160028?pt-manual=DEL- | |
F18_spm.pdf) | Fan, Axial, 5.5″, 120V | |
2 | [2160030](http://www.partstown.com/delfield/del2160030?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, 6.0″ | |
3 | 026-C58-0037 | Shroud, Condenser Coil |
4 | [3526999](http://www.partstown.com/delfield/del3526999?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, Danfoss, NF5.5CLX | |
5 | [2194787](http://www.partstown.com/delfield/del2194787?pt-manual=DEL- | |
F18_spm.pdf) | Start Capacitor |
3516444| Comp, Relay, Overload, NF5.5CLX
6| 3516322| Filter Dryer
7| 075-231-0030| Condensate Pan
8| 3516454| Condenser Coil
Key | Part Number | Description |
---|---|---|
– | 000-BN5-0031 | Assembly, 1/5 Condensing Unit |
1 | [2160028](http://www.partstown.com/delfield/del2160028?pt-manual=DEL- | |
F18_spm.pdf) | Fan, Axial, 5.5.”, 120V | |
2 | [2160030](http://www.partstown.com/delfield/del2160030?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, 6.0″ | |
3 | 026-C58-0037 | Shroud, Condenser Coil |
4 | [3526997](http://www.partstown.com/delfield/del3526997?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, Danfoss, TF4CLS | |
5 | [2194787](http://www.partstown.com/delfield/del2194787?pt-manual=DEL- | |
F18_spm.pdf) | Start Capacitor |
3516446| Comp, Relay, Danfoss
6| 3516322| Filter Dryer
7| 075-231-0030| Condensate Pan
8| 3516454| Condenser Coil
Key | Part Number | Description |
---|---|---|
– | 000-BN5-0054 | Assembly, 1/2HP Cond, Low, Hot gas |
1 | [3516554](http://www.partstown.com/delfield/del3516554?pt-manual=DEL- | |
F18_spm.pdf) | Blade, Fan, 9.00” | |
2 | [2160019](http://www.partstown.com/delfield/del2160019?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, Wire | |
3 | [2162716](http://www.partstown.com/delfield/del2162716?pt-manual=DEL- | |
F18_spm.pdf) | Motor, Fan, 16W, 115V, CW | |
4 | [3516324](http://www.partstown.com/delfield/del3516324?pt-manual=DEL- | |
F18_spm.pdf) | Cutout, High Pressure | |
5 | [3527001](http://www.partstown.com/delfield/del3527001?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, SC12CLX.2,115/60HZ | |
6 | [3516322](http://www.partstown.com/delfield/del3516322?pt-manual=DEL- | |
F18_spm.pdf) | Drier, Filter, (2)Inlet | |
7 | [2194789](http://www.partstown.com/delfield/del2194789?pt-manual=DEL- | |
F18_spm.pdf) | Capacitor, Start, 240MFD | |
8 | [3516441](http://www.partstown.com/delfield/del3516441?pt-manual=DEL- | |
F18_spm.pdf) | Relay, Comp, SC12CLX.2 | |
9 | [3516455](http://www.partstown.com/delfield/del3516455?pt-manual=DEL- | |
F18_spm.pdf) | Coil, Condenser, 1/2 HP | |
– | 024-034-0031 | Pan, Comp, 18.00 |
Key | Part Number | Description |
---|---|---|
– | 000-BN5-0055 | Assembly, 3/4 HP Cond, Low, Hot gas |
1 | [2160019](http://www.partstown.com/delfield/del2160019?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan condenser |
2162716| Motor, condenser fan 16W, 155V
3516433| Blade, fan 10” CW
2| 3527002| Compressor, SC18CLS.2, 115V60hz
3516442| Capacitor, start, run assembly
3| 3516322| Filter drier
4| 3516456| Coil, condenser, 3/4hp
Key | Part Number | Description |
---|---|---|
– | [ 000-BN5-0035](http://www.partstown.com/delfield/del000-bn5-0035 | |
?pt-manual=DEL-F18_spm.pdf) | Assembly, 1/2HP Condenser, Med | |
1 | [3516554](http://www.partstown.com/delfield/del3516554?pt-manual=DEL- | |
F18_spm.pdf) | Condenser fan blade | |
2 | [2160019](http://www.partstown.com/delfield/del2160019?pt-manual=DEL- | |
F18_spm.pdf) | Condenser fan guard | |
3 | [2162716](http://www.partstown.com/delfield/del2162716?pt-manual=DEL- | |
F18_spm.pdf) | Condenser fan motor, 115V | |
4 | [3516462](http://www.partstown.com/delfield/del3516462?pt-manual=DEL- | |
F18_spm.pdf) | Capacitor, start-run assy | |
5 | [3527026](http://www.partstown.com/delfield/del3527026?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, Danfoss, SC12MLX | |
6 | [3516331](http://www.partstown.com/delfield/del3516331?pt-manual=DEL- | |
F18_spm.pdf) | Hi pressure switch | |
7 | [3516322](http://www.partstown.com/delfield/del3516322?pt-manual=DEL- | |
F18_spm.pdf) | Filter Drier | |
8 | 075-231-0031 | Pan, Condensate |
9 | [3516455](http://www.partstown.com/delfield/del3516455?pt-manual=DEL- | |
F18_spm.pdf) | Condenser coil |
Key | Part Number | Description |
---|---|---|
– | [ 000-BN5-0037](http://www.partstown.com/delfield/del000-bn5-0037 | |
?pt-manual=DEL-F18_spm.pdf) | Assembly, 1/3 Condensing Unit | |
1 | [2160028](http://www.partstown.com/delfield/del2160028?pt-manual=DEL- | |
F18_spm.pdf) | Fan, Axial, 5.5″, 120V | |
2 | [2160030](http://www.partstown.com/delfield/del2160030?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, 6.0″ | |
3 | 026-C58-0037 | Shroud, Condenser Coil |
4 | [3527000](http://www.partstown.com/delfield/del3527000?pt-manual=DEL- | |
F18_spm.pdf) | Compress, Danfoss, NF7CLS | |
5 | [2194788](http://www.partstown.com/delfield/del2194788?pt-manual=DEL- | |
F18_spm.pdf) | Start Capacitor |
3516438| Relay, overload, compressor
6| 3516322| Filter Drier
7| 3516458| Receiver tank
8| 075-231-0030| Pan, Condensate
9| 3516454| Condenser Coil
Key | Part Number | Description |
---|---|---|
– | 000-BN5-0053 | Assembly, 1/3HP Cond, w/rec, hg |
1 | [2160028](http://www.partstown.com/delfield/del2160028?pt-manual=DEL- | |
F18_spm.pdf) | Fan, Axial, 5.5″, 120V | |
2 | [2160030](http://www.partstown.com/delfield/del2160030?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, 6.0″ | |
3 | [3516053](http://www.partstown.com/delfield/del3516053?pt-manual=DEL- | |
F18_spm.pdf) | Coil, Solenoid, 120V | |
4 | [3516102](http://www.partstown.com/delfield/del3516102?pt-manual=DEL- | |
F18_spm.pdf) | Valve, Solenoid, 1/4ODF | |
5 | [3527000](http://www.partstown.com/delfield/del3527000?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, NF7.0,115/60HZ, Danfoss | |
6 | [3516438](http://www.partstown.com/delfield/del3516438?pt-manual=DEL- | |
F18_spm.pdf) | Relay, Comp, ovld |
2194788| Capacitor, Start, 320MFD
7| 000-998-0030| High Pressure Assembly, 8Amp
8| 3516397| Accumulator
9| 3516322| Filter Drier, (2)Inlet
10| 3516458| Receiver
11| 3516454| Coil, Condenser
000-BN5-003Y | Assembly, 1/2-1/5 Stacked, |
---|
3516457| Blade, Fan, 7.25 Dia.,
3516433| Blade, fan, 25deg, 10″, cw
2194789| Capacitor, start, 240mfd
2194787| Capacitor, start, 280mfd
3516454| Coil, Condenser, 1/5, 1/4,
3516455| Coil, Condenser, 1/2 Hp
3526997| Compressor, 1/5hp, 115/60, r404a
3527001| Compressor, sc12clx.2, 115/60hz,
3516322| Drier, filter, (2)inlet
2160020| Guard, Fan, 7.25
2160019| Guard, fan, wire
2162717| Motor, fan, 9w, 115v, cw
2162513| Motor, fan, 35w, blast
3516193| Regulator, pressure, 1/2
3516446| Relay, Compressor, Danfoss
3516441| Relay, compressor, sc12clx.2
3516225| Valve, expansion, frz, 1/4ton
000-BN5-0040 | Assy, 1/3-1/5 Stacked, |
---|
3516457| Blade, Fan, 7.25 Dia.
2194787| Capacitor, start, 280mfd
2194788| Capacitor, start, 320mfd
3516454| Coil, Cond., 1/5, 1/4
3526997| Comp, 1/5hp, 115/60, r404a
3527000| Comp, nf7cls, 115v/60hz
3516322| Drier, filter, (2)inlet
2160020| Guard, Fan, 7.25
2162717| Motor, fan, 9w,115v,cw
3516193| Regulator, pressure, 1/2
3516446| Relay, Comp, Danfoss
3516438| Relay, comp, ovld, nf7clx
3516225| Valve, exp, frz, 1/4ton
359-478-003E | Panel, louver, 15.0, ptb |
---|
359-478-003D| Panel, louver, 18.0, ptb
356-478-0038| Panel, louver, 14.0, sw
Cut,lh
356-478-0039| Panel, louver, 18.0, sw
Cut, lh
000-187-0081| Door Assembly, ref, 27×26, rt, 430
---|---
000-187-0082| Door Assembly, ref, 27×26, lt, 430
000-187-006B| Door Assembly, ref, 27×26, lt
000-187-006A| Door Assembly, ref, 27×26, rt
1701185| Gasket, door, 27, mark7
0420067| Hinge Kit
000-402-0054 | Cover Assembly, hinged, 6 Pan, ptl |
---|---|
000-402-0056 | Cover Assembly, hinged, 6pan, l/t |
9321374| Pin, hinge, salad Pan
3234266| Hinge, pan Cover, end, rh,
3234282| Hinge, pan Cover, end, lh,
3234392| Hinge, pan Cover,
Standard Labor Guidelines To Repair Or Replace Parts On Delfield
Equipment
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.
- A maximum of 1-hour is allowed to diagnose a defective component.
- A maximum of 1-hour is allowed for retrieval of parts not in stock.
- A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
- Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work Authorization from Delfield. You must submit the number with the service claim.
Labor Of 1-Hour Is Allowed To Replace:
- Thermostat
- Infinite Switch
- Door Jamb Switch
- Solenoid Coil
- Hi-limit/Thermal Protector Switch
- Fan Delay/Defrost Termination Switch
- Compressor Start Components and Overload Protector
- Defrost Timer
- Thermometer
- Gear Box
- Contactor/Relay
- Transformer
- Evaporator/Condenser Fan Motor and Blade
- Circulating Fan Motor and Blade
- Microprocessor Control
- Water Level Sensor/Probe
- Door Hinges, Locks, and Gaskets
- Condensate Element
- Springs/Lowerator
Labor Of 2 Hours To Replace:
- Drawer Tracks/Cartridges
- Pressure Control
- Solenoid Valve
- Defrost Element
- Heating Element
- Locate/Repair Leak
Labor Of 3 Hours To Replace:
- EPR or CPR Valve
- Expansion Valve
- Condenser or Evaporator Coil
Labor Of 4 Hours To Replace:
- Compressor
This includes recovery of refrigerant and leak check.
$55.00 maximum reimbursement for refrigerant recovery (includes recovery
machine, pump, torch, oil, flux, minor fittings, solder, brazing rod,
nitrogen, or similar fees.)
Refrigerants:
- R22 A maximum of $4.00/lb. or 25¢/oz. will be reimbursed.
- R134A A maximum of $5.00/lb. or 31¢/oz. will be reimbursed.
- R404A A maximum of $16.00/lb. or $1.00/oz. will be reimbursed.
Notes
|
---|---
Thank you for choosing Delfield!
Help is a phone call away. Help our team of professional, courteous customer
service reps by having your model number and serial number available at the
time of your call 800-733-8829.
Model: __ S/N:
Installation Date: ___ For a list of Delfield’s authorized parts
depots, visit our website at www.delfield.com
Register your Delfield warranty online. Go to
www.delfield.com under the service tab to complete.
For customer service, call
800-733-8829,
800-773-8821, Fax
989-773-3210,
www.delfield.com
980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A.
•989-773-7981 or
800-733-8829 • Fax
989-773-3210 •
www.delfield.com
Delfield reserves the right to make changes in design or specifications
without prior notice.
©2013 The Delfield Company. All rights reserved. Printed in the U.S.A.
DM18 07/13
9291454
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>