STRUCTUBE AI17.72.58 Lifestyle Adjustable Twin XL Bed
COMPONENTS
Sync cable and sync strap will only be used when 2 bases are being linked together. If not being used, please keep in a safe place for possible future use.
PLEASE NOTE
- FOR USER SAFETY PERIODICALLY VERIFY AND TIGHTEN ALL FITTINGS
- THIS ITEM IS DESIGNED FOR RESIDENTIAL USE ONLY
- USE POWER TOOLS ONLY WHEN INDICATED
- FOR AFTER-SALES PARTS SERVICE PLEASE REFERENCE
- ASSEMBLY INSTRUCTIONS MAY BE REVISED AT ANY TIME. THE MOST RECENT VERSION CAN BE FOUND BY VISITING
- WWW.STRUCTUBE.COM
CLEAN AND CARE
To keep your fabric upholstered furniture looking new, keep it away from direct sunlight as it may discolor over time. Use a vacuum cleaner with a gentle fabric attachment to remove dust and debris as needed. Spills must be cleaned immediately. Avoid rubbing or dabbing as it will penetrate deeper into the fabric fibers and possibly into the stuffing below. Attempt to soak up as much as possible with a paper towel or other very absorbent clean/dry cloth. For spills that result in stains, first attempt to clean with mild diluted dish soap in water, and if that doesn’t work consult a furniture cleaning specialist. Structube does not test nor recommend any particular cleaning product. After cleaning make sure to dry the area with a fan or blow dryer without heat. When vacuuming underneath, do not drag as it may dislodge the legs and/or damage the frame. Take good care of your new item and it will take care of you!
BEFORE USE
READ ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS.
- Two-person assembly/movement of the base is required.
- Carefully remove packaging taking extra caution if using a knife to not unintentionally cause damage.
- Double-check when discarding packaging that no parts/pieces are still within.
- Only use the components provided by the manufacturer. Do not add on any aftermarket parts or accessories.
- CRUSH/PINCH WARNING – This product has moving parts and can cause serious injury. Please keep fingers clear of moving parts, allow enough clearance for freedom of movement, and above all else ensure there are no children or pets under or around the bed.
- CHOKING HAZARD – This product contains small parts. Prevent serious injury and suffocation, keep children and pets away from small parts.
ELECTROCUTION WARNING
- Always unplug this bed from the electrical outlet before cleaning or servicing.
- Do not modify or add any electrical components including adapters for different regional voltage.
- Ensure the electrical outlet is properly grounded. A surge protector between the outlet and bed base is recommended.
- Ensure all electrical cables are free and clear of moving parts to prevent crushing and possible electrocution.
- Do not use liquids on or near this product. If spillage occurs, disconnect the power immediately and ensure all components are completely dry before reconnecting.
- Never operate with a damaged cord or plug.
- Keep the cord away from heated surfaces.
- Do not use sharp objects on or near.
- Do not use this product outdoors.
- The product should not be placed in an area that is too humid or exposed to direct sunlight, and the air should be kept properly circulated so as not to affect the normal use of the product.
PACEMAKERS
- Some pacemakers may detect motion by this product as a false sense of movement or exercise. This may or may not affect your pacemaker. Talk to a physician to address any concerns.
HOME USE / HOSPITAL DISCLAIMER
- This product is designed solely for in-home use and not as a hospital bed. The product has not been tested to meet hospital standards. Do not use with oxygen or other flammable gasses.
WEIGHT RESTRICTION
- The recommended weight restriction is 850 lbs. [including the weight of the mattress, bedding, and user(s).
- This product will support the recommended weight limits when weight is distributed evenly across the base. Thisproduct is not designed to support or lift this amount in the head or foot sections alone. Consumers should not enter or exit the bed when any portion of it is in the raised position. Do not sit on the head or foot sections while in the raised position. Exceeding the recommended weight restrictions or other misuse of this product could damage the bed and void the warranty.
PRODUCT RATINGS
IMPORTANT: USE THIS PRODUCT ONLY AS DESCRIBED IN THESE INSTRUCTIONS. DO
NOT MODIFY ANY PARTS OR COMPONENTS.
MOTOR RATINGS
The motors are not designed to operate for more than two continuous minutes
within an18-minute time period. Exceeding this rating will shorten the life of
the motors and void the warranty.
POWER RATINGS
- INPUT: AC 100-240V – 50/60Hz, 1.5 Amp
- OUTPUT: DC 29V-2A
- Do not attempt any electrical maintenance or modification. Do not open any electrical components, alter the wiring, modify the base, or change the product in any way as it may result in electrocution and will void the warranty.
FCC COMPLIANCE (USA)
- This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- Operates on 2.4 GHz frequency transmitter.
- To comply with the FCC RF exposure requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirement and void the user’s right to operate the device.
ELECTRICAL OVERVIEW
- Remove the bed base from the box, and unfold it top-side down on a clean/level surface.
- Remove the parts box.
Attached the legs:
-
Select from 3 possible heights. Ensure all 6 legs are adjusted to the same height.
-
Affix included felt pads.
-
The base may b`e used without legs. Ensure it is fully supported ONLY on the metal frame where the legs would be affixed. Affix the felt pads directly on the metal frame.
-
Connect the power supply.
-
With a minimum of two persons turn the base over. Insert the mattress retainer bar.
Warning
Use caution when lifting the base. Do not hold by the fabric. Take care of hands and fingers to avoid crushing/pinching. Do not pivot on any of the legs. -
Connect the power. Test all functions BEFORE placing the mattress.
BACKUP BATTERY OPERATION
For emergency use only, in case of a power outage. Battery backup is not to be used for regular operation of the bed.
Note: Only head down and foot down keys are operational.
- Disconnect the electrical cable from the outlet.
- Disconnect the power supply to the control box.
- Connect 2 new, same brand, alkaline 9V batteries (not included) to the holder.
- Connect the battery backup to where the power supply control box was previously connected.
- Using the head down and foot down buttons on the remote lower to the desired position.
- Once done, remove the battery backup and reconnect the power supply control box.
- It is recommended to reconnect the power to the outlet only after electricity is restored.
LIFESTYLE ADJUSTABLE TWIN XL BED “LOFT” OPERATION MANUAL
Remote Control Overview
OPERATING THE REMOTE
PROGRAMMING MEMORY M1 and M2
- To save to M1 – Press & hold the “M1” button until the backlight flashes 3 times (approx. 5 seconds).
- To save to M2 – Press & hold the “M2” button until the backlight flashes 3 times (approx. 5 seconds).
CHILD LOCK FUNCTION
Press & hold simultaneously until the backlight flashes 3 times (approx. 5 seconds). Once the child safety lock is activated all buttons will be inoperable and if pushed the backlight will flash twice.
TO DEACTIVATE
Press & hold the simultaneously until the backlight flashes 2 times. Keep holding until the backlight flashes another 3 times. The child lock is now deactivated.
SYSTEM RESET
- Press & hold the ”ZeroG” + ”FLAT” simultaneously until the backlight flashes 3 times. All functions are reset to factory settings.
SYNCHRONIZING TWO BASES
NOTE
-
BEFORE SYNCHING THE REMOTE PLEASE ASSEMBLE THE SYNC STRAP AND SYNC CABLE
-
WITH THE BASES LINKED TOGETHER DO NOT OPERATE ANY FUNCTION ON THE REMOTE UNTIL IT HAS BEEN SYNCED OR RISK DAMAGING THE BASES
-
SYNC ON
Press & Hold ”FLAT” until the backlight flashes 3 times (approx. 5 seconds) -
SYNC OFF
Press & Hold ”FLAT” until the backlight flashes 3 times (approx. 5 seconds)
INSTALLATION OF SYNC STRAP AND SYNC CABLE
- DISCONNECT THE POWER FROM THE WALL OUTLET
- Place both bases side-by-side and connect the sync strap by loosening the feet at the uppermost height (touching the metal frame). Do this twice – Once at the level of the head and once at the level of the foot.
- Connect the sync cable to the multifunction port (MFP) of each control box.
- Reconnect the power to the wall outlet.
- Follow the steps to synchronize the remote.
Remote Control Pairing
The remote control and base are paired before leaving the factory. If the remote is not working first verify if the batteries are good.
STEPS TO PAIR
-
Unplug the power ensuring the power light goes out.
-
Replug the power immediately pressing and holding simultaneously.
-
The remote backlight flashes to indicate it is pairing. Pairing is completed once the flashing stops.
Troubleshooting
DO NOT OPEN OR ATTEMPT TO REPAIR ANY ELECTRICAL COMPONENTS ENSURE THE BASE IS UNPLUGGED WHEN VERIFYING CABLES AND CONNECTIONS THE BASE HAS MOVING PARTS, TAKE CAUTION TO AVOID FINGER PINCH AND/OR CRUSHING INJURIES
Problem | Solution |
---|---|
The base will not function | 1. Verify if child lock function is activated. |
2. Verify if all electrical connections are secure.
3. Verify that the wall outlet has power.
4. Ensure there is nothing under or near the bed that may impede its movement.
5. Verify if the battery in the remote is good.
6. Attempt a system reset.
7. Re-pair the remote.
A ‘click’ sound is heard under the adjustable bed when raising or lowering the head section.| The motor makes a clicking sound when in operation. This is normal. No action is required.
The adjustable bed squeaks.
| Lubricate all fittings.
Zero Gravity, M1, and/or M2 buttons don’t
work.
| Press and hold the FLAT button until the bed is fully flat.