COMPONENTS
Sync cable and sync fastener will only be used when 2 bases are being linked together. If not being used, please keep in a safe place for possible future use.
PLEASE NOTE
- THIS ITEM IS DESIGNED FOR RESIDENTIAL USE ONLY
- FOR USER SAFETY PERIODICALLY VERIFY AND TIGHTEN ALL FITTINGS
- USE POWER TOOLS ONLY WHEN INDICATED
- FOR AFTER-SALES PARTS SERVICE PLEASE REFERENCE: 17.72.58.v1_117794
- ASSEMBLY INSTRUCTIONS MAY BE REVISED AT ANY TIME. THE MOST RECENT VERSION CAN BE
FOUND BY VISITING: WWW.STRUCTUBE.COM
CLEAN AND CARE
To keep your furniture looking new, keep it away from direct sunlight as it may discolor over time. Use a vacuum cleaner with gentle fabric attachment to remove dust and debris as needed. Spills must be cleaned immediately. Avoid rubbing or dabbing as it will penetrate deeper into the fabric fibers and possibly into the stuffing below. Attempt to soak up as much as possible with paper towel or other very absorbent clean/dry cloth. For spills that result in stains, first attempt to clean with mild diluted dish soap in water, and if that doesn’t work consult a furniture cleaning specialist. Structube does not test nor recommended any particular cleaning product. After cleaning make sure to dry the area with a fan or blow dryer without heat. When vacuuming underneath, do not drag as it may dislodge the legs and/or damage the frame. Take good care of your new item and it will take care of you!
BEFORE USE
READ ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE USING THIS PRODUCT.
SAVE THESE INSTRUCTIONS.
- Two-person assembly / movement of the base is required.
- Carefully remove packaging taking extra caution if using a knife to not unintentionally cause damage.
- Doublecheck when discarding packaging that no parts/pieces are still within.
- Only use the components provided by the manufacturer. Do not add on any aftermarket parts or accessories.
- CRUSH/PINCH WARNING – This product has moving parts and can cause serious injury. Please keep fingers clear of moving parts, allow enough clearance for freedom of movement, and above all else ensure there are no children or pets under or around the bed.
- CHOKING HAZARD – This product contains small parts. Prevent serious injury and suffocation, keep children and pets away from small parts.
ELECTROCUTION WARNING
- Always unplug this bed from the electrical outlet before cleaning or servicing.
- Do not modify or add any electrical components including adapters for different regional voltage.
- Ensure the electrical outlet is properly grounded. A surge protector is recommended.
- Ensure all electrical cables are free and clear of moving parts to prevent crushing them and possible electrocution.
- Do not use liquids on or near this product. If spillage occurs, disconnect the power immediately and ensure all components are completely dry before reconnecting.
- Never operate with a damaged cord or plug.
- Keep the cord away from heated surfaces.
- Do not use sharp objects on or near.
- Do not use this product outdoors.
- The product should not be placed in an area that is too humid or exposed to direct sunlight, and the air should be kept properly circulated so as not to affect the normal use of the product.
PACEMAKERS
- Some pacemakers may detect motion by this product as a false sense of movement or exercise. This may or may not affect your pacemaker. Talk to a physician to address any concerns.
HOME USE / HOSPITAL DISCLAIMER
- This product is designed solely for in-home use and not as a hospital bed. The product has not been tested to meet hospital standards. Do not use near pure oxygen or other flammable gasses.
WEIGHT RESTRICTION
- The recommended weight restriction is 850 lbs; including the weight of the mattress, bedding, and user(s).
- This product will support the recommended weight limits when weight is distributed evenly across the base. This product is not designed to support or lift this amount in the head or foot sections alone. Consumers should not enter or exit the bed when any portion of it is in the raised position. Do not sit on the head or foot sections while in the raised position. Exceeding the recommended weight restrictions or other misuse of this product could damage the bed and void the warranty.
MOTOR RATINGS
The motors are not designed to operate for more than two continuous minutes within an18-minute time period. Exceeding this rating will shorten the life of the motors and void the warranty.
POWER RATINGS
- INPUT: AC 100-240V – 50/60Hz, 1.5 Amp
- OUTPUT: DC 29V-2A
- Do not attempt any electrical maintenance or modification. Do not open any electrical components, alter the wiring, modify the base, or change the product in any way as it may result in electrocution and will void the warranty.
FCC COMPLIANCE (USA)
- This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device does not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- Operates on 2.4 GHz frequency transmitter.
- To comply with the FCC RF exposure requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirement and void user’s right to operate the device.
ELECTRICAL OVERVIEW
PLEASE FOLLOW STEP-BY-STEP:
- a. Remove the bed base from the box, unfold top side down on a clean/level surface.
**b. Remove the parts box from under the base.
**
-
a. Assemble the legs to the desired height by attaching sections together ensuring all 6 legs are at the same height (i.e. have the same number of sections).
b. Attach legs to the bed and stick felt pads underneath.
NOTE: If using the LOFT adjustable base inside a bedframe, the base’s legs may not be needed. If so, ensure the adjustable base’s metal frame is directly supported in the same six places where the legs would normally be, and stick the felt pads directly on the metal frame.**** -
**Connect the power supply.
**
- **With a minimum of two persons turn the base over. Insert the mattress retainer bar.
**
Use caution when lifting the base. Do not hold by the fabric . Take care of hands and fingers to avoid crush/pinch. Do not pivot on any of the legs
- Connect the power. Test all functions BEFORE placing the mattress.
BACKUP BATTERY OPERATION
For emergency use only, in case of a power outage. Battery backup is not to be used for regular operation of the bed. (Note: Only head down and foot down keys are operational.)
-
Disconnect the electrical cable from the outlet.
-
Disconnect the power supply to the control box.
-
Connect 2 new, same brand, alkaline 9V batteries (not included) to the holder.
-
Connect the backup battery holder to the control box where the power supply was previously connected.
-
Using the head down and foot down buttons on the remote lower to desired position.
-
Once done, remove the backup battery holder and reconnect the power supply to the control box.
-
It is recommended to reconnect the power to the outlet only after the electricity is restored.