WARNING
- This appliance can be used by children 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervisor instruction concerning the use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be done by children without supervision.
- Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
- If the power cord on this unit is damaged, it must be replaced by the manufacturer, its service agent or qualified persons in order to avoid a hazard.
- Only install and operate this appliance as outlined in this instruction manual. At all times, use care when using this appliance.
- This appliance is only designed for home air-conditioning.
- Do not modify this appliance in any way to avoid danger.
- Electrical equipment and installations regulated by national legislation must be followed.
- Children must not use this appliance unsupervised.
- For safety reasons, anyone with psychological, physical or any medical condition that may impair judgment should only use this appliance when under the supervision of a responsible adult.
- For safety sake, never use a damaged power cable. Always refer to the manufacturer or an authorized technical service center if appliance requires repair.
- It is essential that the appliance is connected to an efficiently grounded system checked by a qualified electrician.
- The use of extension cords is not recommended.
- The air filter should be cleaned a minimum of once a week.
- Do not place the air conditioner near any heating appliance.
- The appliance should be transported upright or on its side. Any internal circuit water should be emptied before moving. Do not turn on the appliance for at least one hour before starting it.
- Flammable substances or pressurized containers (e.g. aerosol cans) should be kept a minimum of 50 cm away.
- The appliance should not be installed in rooms containing sulphur, gas or oil.
- Do not disconnect the appliance by pulling on the power cable. Always disconnect the appliance before any cleaning or maintenance is undertaken.
- Do not store anything on top of the appliance, especially heavy or hot objects.
- Repairs must only be undertaken by manufacturers’ authorized service centers. Failure to comply may be dangerous.
- Do not store the appliance covered with plastic bags.
- Remember the environment when disposing of packaging around the appliance and when the appliance has reached its used by date.
- READ THE MANUAL CAREFULLY BEFORE USING THE APPLIANCE.
- Stagnation of possible leaks of refrigerant gas in unventilated rooms could lead to fire or an explosion hazard should the refrigerant come in contact with electric heaters, stoves or other sources of ignition.
- Use care when storing the appliance to prevent mechanical faults.
- Only persons authorized by an accredited agency certifying their competence to handle refrigerants in compliance with sector legislation should work on refrigerant circuits.
- Maintenance and repairs requiring the assistance of other qualified personnel must be carried out under the supervision of specialists in the use of inflammable refrigerants.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn.
- Be aware that refrigerants may not contain an odour.
- Improper handling can cause serious damage to the appliance.
- Read this manual carefully before operating the unit.
- At least 50 cm air space between front/left/right/top sides of portable air conditioner and at least 80 cm air space between rear of portable and adjacent obstacle should be maintained during normal operation.
- Do not place the unit in front of curtains or drapes in case they fall against the back air intake.
- If the power cord on this unit is damaged it must be replaced by the manufacturer.its service agent or qualified persons in order to avoid a hazard.
- This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance.
Identification of parts
-
Control panel
-
Air outlet
-
Handle hole
-
Caster
-
Air filter
-
Air outlet ( Heat exchange )
-
Air intake ( Evaporator )
-
Air intake ( Condenser )
-
Water outlet drain for continuous drain operation
( Dehumidify mode only ) -
Water outlet drain
(Note: Please ensure that the water outlet drain is properly installed before use.) -
Power supply cord
-
Built-in drain pump
OPERATION
CONTROL PANEL
Power Control
The power control turns the unit on and off.
Warning Light
Condensed water may accumulate in the unit. If the internal tank becomes full,
the Warning Light will shine and the unit will not operate until the unit has
been drained.
Mode Control
The Mode Control has 4 settings:
Cool • Dehumidify • Fan • Heating The settings are adjusted with Mode Control button. A light will indicate which setting is
-
Cooling Mode
During the cooling mode the air is cooled and hot air is exhausted to the outside through the exhaust tube. Adjust fan speed and air temperature to suit your desired comfort level.
Note: The air exchange hoses must vent outside the room when using cool mode. -
Dehumidify Mode
Air is dehumidified as it passes through the unit, without being in full cooling mode. If room temperature is > 25 degrees Celsius, fan speed can be adjusted; otherwise fan speed is fixed to” low”. Note: If the unit is to be used as a dehumidifier, do not connect the exhaust hose let the warm air return to the room. Continuous drainage is then necessary. -
Fan Mode
Air is circulated throughout the room with no cooling. Note: The unit does not need to be vented in Fan mode -
Heating Mode
When Heating mode is selected the indicator light will shine red. The heating is activated only when the ambient temperature is below 25 degrees Celsius.
Note: The air exchange hoses must vent outside the room when using heating mode.
Fan Speed Control
The Fan Speed Control has 3 settings: High, Medium, and Low.
Timer
-
Auto turn off :
With machine in running mode, press timer button to select number of hours you would like the unit to run in air conditioning mode until it automatically shuts off. -
Auto turn on :
With machine in stand by mode, press timer button to select number of hours until you would like the unit to automatically start running in air conditioning mode.
Timer / Temp set controls
- Used for adjusting the timer and thermostat.
- The default display is room temperature.
- In cooling mode, when “+” or ” -“button is pressed, the set temperature is displayed and may be adjusted.
A few seconds after, the display will revert back to room temperature. Temperature is only adjustable in cool mode. The time is adjustable between 1 ~24 hours. Note : By pressing both ” + “/ ” -” set buttons at the same time, the display will toggle between Celsius and Fahrenheit.
Auto swing control
Auto swing function switch
Display
You can turn the front and top panel lights on and off by hitting the Lamp On/Off switch.
After switching the air conditioner off, you must wait 3 minutes before switching it back on again.
Air Conditioner Remote Control
The functions work the same as your air conditioner’s touch controls.
All key functions can be accessed from the remote control.
CONTROL PANEL
CAUTION
- Use only AAA or IEC R03 1.5V batteries.
- Remove the batteries if the remote control is not used for a month or longer. Do not attempt to recharge the supplied batteries.
- All batteries should be replaced at the same time, do not mix old battery.
- Do not dispose of the batteries in a fire as they may explode.
Installation Instructions
Accessories Include
Installation
- Connect the connectors #2 and #3 to 2 sides of exhaust hose #1 to create an exhaust assembly.
- Sliding in one end of hose assembly to rear panel.
- Insert the window panels B and C to each end of main panel A. Adjusting to fix the length of window panels by using the screws and nuts mounted on the 2 ends of main panel A.
- Open the window and place window panels into window. Adjust the extension panels to fit width or height of window by the screw and nut sets mounted on the main panel A.
- Insert the other end of exhaust hose assembly onto window panel and turn counterclockwise to secure.
- Repeat procedures 1-5 above for the installation of second hose assembly.
- Plug the power cord into the wall outlet and press the “Reset” button.
- When removing the portable air conditioner for storage, the window panel may be left in place. Simply place the cover #5 to cover the hole on the window panel.
Continuous Drainage
Built-in Drain Pump
The condensate produced in heating mode can also be drained through the supplied drain hose utilizing the internal built-in drain pump. Follow the steps below for proper operation of the pump. NOTE : The built in drain pump can be used in all modes.
Installation : (See Figures 1 &2)
- STEP 1. Connect the supplied drain hose to the drain key.
- STEP 2. Connect the drain key and hose to the drain outlet located on the rear panel.
- STEP 3. Lead the other end of drain hose to a suitable location for drainage, like a drain or sink or the outlet located on the window panel kit. Use caution when using the drainage outlet on window panel kit to avoid creating a slipping hazard.
Dismantle: (See Figure 3)
- STEP 1. Press the release button on the unit rear panel. STEP 2. Pull out the drain key and hose.
- STEP 3. Store the drain hose for next time usage.
(No image for this step)
Troubleshooting
Care and Maintenance
Maintenance after using
- lf the appliance will not be used for a long time, be sure to pull out the rubber plug of the drain port underside, in order to drain the water.
- Before storing away run the unit in fan mode only for few hours to dry any moisture on the coils to prevent mold.
- Stop the appliance and pull out the power supply plug, then take out the batteries of remote controller and keep it in a safe place.
- Clean the air filter and reinstall it.
- Remove the air hoses and keep them in a safe place, and cover the hole tightly.
Specifications
-
Figures noted, in the contents are for reference only; variation may result due to application in different countries or regions, and shall be based on the best of practical operation.
-
Description of product
Heat Pump Portable Air Conditioner -
Model
ZHP14DB -
Voltage/Frequency
AC 115V ~ 60Hz -
Current Consumption
10.5A -
Coolant
R32 -
Timer
24 hour -
Dimensions
(W)x(H)x(D) 447 x 747 x 405 mm -
Weight (N.W.)
35 kg -
Working Temperature/Humidity
16 °C-35°C I 30%-80%RH (Cooling)
10 °C-25°C / 30%-80%RH (Heating)
-
-
Wiring diagram affixed inside the rear panel
Disposal
“Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.”