Friedrich SS12 Room Air Conditioner Installation Guide
- June 17, 2024
- FRIEDRICH
Table of Contents
- SS12 Room Air Conditioner
- WARNING: Before operating your unit
- How to operate your Friedrich room air conditioner
- How to use the remote control(optional)*
- Removing and cleaning the filter/ fresh air and exhaust feature
- Troubleshooting tips
- ROOM AIR CONDITIONERS LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Operating Guide
Quiet Master Electronic®
Room Air Conditioner I with remote control
115-Volt: SSO8R I SS09 I SS1OR I SS12R I SS14R 230-Volt: SS121 SS161 SM18R I
SM20
- Remote control included on SS08R, SS10R, SS12R, SS14R and SM18R
America’s Best Air Conditioner
920-090-04 (01-03)
SS12 Room Air Conditioner
Please register your air conditioner
Model information can be found on the name plate behind the front.
Please complete and mail the owner registration card furnished with this
product, or register on-line at www.friedrich.com
(USA only). For your future convenience, record the model information here.
MODEL NUMBER
SERIAL NUMBER
PURCHASE DATE
Congratulations!
You have purchased the very latest in room air conditioner technology. Your
new Friedrich high efficiency room air conditioner will give you many years of
dependable service. Many extra features have been built into your Friedrich
air conditioner to assure quiet operation, the best circulation of cool, dry
air, functional controls, and the most economical operation.
WARNING: Before operating your unit
Make sure the wiring is adequate for your unit.
If you have fuses, they should be of the time delay type.
Before you install or relocate this unit, be sure that the amperage rating of
the circuit breaker or time delay fuse does not exceed the amp rating listed
in Figure 1. DO NOT usean extension cord.
The cord provided will carry the proper amount of electrical power to the
unit; an extension cord will not.
Make sure that the receptacle is compatible with the air conditioner cord plug
provided.
This insures proper _ounding.
If you have a two prong receptacle you will need to have the circuit replaced
by a certified electrician with a grounded circuit that meets all national and
local codes and ordinances. Under no circumstances should you remove the
ground prong from the plug. You must use the three prong plug furnished with
the air conditioner.
MODEL| CIRCUIT RATING OR
TIME DELAY FUSE| PLUG FACE
---|---|---
SSO8R • SSO9 • SS1OR SS12R • SS14R| AMP| VOLT| N° NEMA|
15| 125| 5-15P|
SS12 • SS16 • SM18R • SM20| 15| 250| 6-15P|
Figure 1
Keepthe filter clean
Make sure that your air conditioner is always in top performing condition by
cleaning the filter regularly.
Instructions for removing and cleaning the filter can be found on page 7.
Provide good air flow
Make sure the airflow to and from the unit is clear. Your air conditioner puts
the air out at the top of the unit, and takes in air at the bottom. Airflow is
critical to good operation.
It is just as important on the outside of the building that the airflow around
the unit exterior is not blocked.
Unit placement
If your air conditioner can be placed in a window or wall that is shaded by a
tree or another building, the unit will operate even more efficiently. Using
drapes or blinds on the sunny side of the dwelling will also add to your
unit’s efficiency.
Insulation
Good insulation will be a big help in maintaining desirable comfort levels.
Doors should have weather stripping. Be sure to caulk around doors and
windows.
How to operate your Friedrich room air conditioner
To start unit
-
If your air conditioner is installed and plugged into a proper receptacle, it is ready to go. Touch ON/OFF button once. The unit will automatically be in COOL mode with the temperature set at 75°F (24°C) and the fan speed at F1, the sleep setting. There is a 3-minute delay before the compressor will turn on. (See next page, ‘Automatic Component Protection.”)
-
Should the FILTER ALERT light turn on when you first turn on the unit, touch FILTER ALERT to turn off the light. FILTER ALERT light will come on after 250 hours of use. (See page 7 for filter cleaning instructions.) Touch FILTER ALERT to reset.
To set mode of operation -
When you first turn on the unit, it will be in the COOL mode (light on), with constant fan.
-
Touch Money Saver ® (light on) to activate the Money Saver ®feature. Money Saver ®is a feature that cycles the fan with the compressor so that the fan does not run all the time. This saves energy and improves dehumidification. Money Saver ® will also run to test the temperature if the off cycle is too long. Or you may prefer constant fan for more air movement. To return to constant fan, touch COOL.
-
Touch FAN ONLY (light on) if you want only the fan to run. You may want to use this feature in conjunction with the FRESH AIR / EXHAUST lever to bring outside air into a room, or to exhaust stale air. (See page 7, “Fresh Air and Exhaust Control” for more information.)
To adjust temperature
[60°F (16°C) to 90°F (32°C)] -
COOLER- Touch COOLER to see setting, touch again to change.
-
WARMER – Touch WARMER to see setting, touch again to change.
-
Touch °F/°C to show desired temperature in Fahrenheit or Celsius.
To adjust fan speed -
Touch SPEED 1-4 to see current setting. Touch again to change speed. F1 is the lowest setting (SLEEP SETTING), F2 is low speed (LOW), F3 is medium speed (MED), F4 is high speed (HIGH).
To activate smart fan -
Touch SMART FAN (light on). Smart Fan will adjust the fan speed automatically to maintain the desired comfort level. For example, if the outside doors in your home are open for an extended period of time, or more people enter a room, Smart Fan may adjust to a higher fan speed to compensate for the increased heat load.
This keeps you from having to adjust the fan speed on your own. Smart Fan cannot be activated in the FAN ONLY mode.
To deactivate smart fan -
Touch SPEED 1-4, and select your desired fan speed.
To set hour clock -
Press SET HOUR CLOCK once to see the current clock setting. Continue pressing the button until the hour closest to the actual time appears in the display. MAKE SURE YOU SET A.M. AND RM. PROPERLY. A light will appear in the upper left corner of the display when the hour is p.m. Minutes will NOT show on display.
To set the timer
NOTE: SET HOUR CLOCK before attempting to set timer functions.
You can set the A/C START and AJC STOP timer a minimum of one hour apart and a maximum of twenty-three hours apart. -
TIMER STOP – Press the AJC STOP button and hold until the hour you want the unit to shut off appears in the display (A.M. or RM.). The stop time for cooling will then be set.
-
START TIME- Press AJC START to view the current start time for cooling. Continue pressing until the hour you want the unit to start appears in the display (A.M. or RM.). The start time for cooling will then be set.
-
Press the TIMER ON/OFF button once to activate (light on) the timer function. Touch TIMER ON / OFF again (light off) to cancel the timer function if you so desire. Once the on and off times have been selected, they will remain in memory, and cycle daily until changed.
NOTE: If unit is unplugged or power is interrupted, the SET HOUR CLOCK button must be reset or the TIMER ON/OFF functions will not work.
Automatic component protection
Your unit is equipped with Automatic Component Protection.
To protect the compressor of the unit, there is a three minute time delay if
you turn the unit off or if power is interrupted.
The fan will not be affected. Also, if you switch from COOL mode to FAN ONLY,
and switch back to COOL mode, there is a three minute delay before the
compressor comes back on.
How to use the remote control(optional)*
NOTE: Physical appearance of your remote control may vary.
Follow instructions for the illustration that best resembles your remote.
To start unit
-
POWER – Press the POWER button once. The unit will automatically turn on in the mode and fan speed it was last left on.
To set mode of operation -
COOL – Press the COOL button to automatically switch the operating mode to COOL.
-
FAN ONLY- Press the FAN ONLY button if you want to run the fan only. You may want to use this feature in conjunction with the FRESH AIR/EXHAUST if you want to bring outside air into the room, or exhaust stale air. (The FRESH AIR/EXHAUST feature is located on the front of the air conditioner near the top. See page 7, Figure 6.)
-
Money Saver ® – Press the Money Saver ® button to activate the Money Saver ® feature. Money Saver ® is the feature that cycles the fan with the compressor so that the fan does not run all the time.
To adjust temperature -
WARMER – Press the TEMP • button to raise the temperature setting.
-
COOLER – Press the TEMP • button to lower the temperature setting.
To adjust fan speed -
FAN SPEED- Press the FAN SPEED button to see the current setting. Press again to change the fan speed. F1 is the lowest setting (SLEEP SETTING), F2 is low speed (LOW), F3 is medium (MED), and F4 is high (HIGH).
To set the hour clock -
SET HOUR CLOCK – Press SET HOUR once to see the current clock setting. Continue pressing the button until you arrive at the current time. MAKE SURE YOU SET THE A.M. AND RM. PROPERLY. (NOTE: MINUTES ARE NOT SHOWN ON THE DISPLAY.) A light will appear in the upper left comer of the display when the hour is RM.
To set the timer
NOTE: Set the hour clock before attempting to set timer functions. You can set the timer ON/OFF a minimum of one hour apart, and a maximum of 23 hours apart. -
TIMER START – Press START to view the current start time for cooling. Continue pressing the START button until you arrive at the start time you desire. The start time for cooling will then be set.
-
TIMER STOP – Press the STOP button. Continue pressing the STOP button until you arrive at the stop time you desire. The stop time for cooling will then be set.
-
TIMER ON/OFF – Press the ON/OFF button once to activate (light on) or deactivate (light off) the timer. Once the START and STOP times have been selected, they will remain in memory, and cycle daily until changed.
NOTE: If the unit is unplugged or the power is interrupted, the HOUR CLOCK must be reset or the TIMER ON/OFF functions will not work.
- A Friech%h RCI wireless remote control can be used to operate all Quiet Master _Electronic models. A remote is included with the SS08R, SSIOR, SSI 2R, SSI4R and SSI 8R. _lbadd an RCI remote to other Friedfich models, please visit your local authorized Friech%h Dealer.
Removing and cleaning the filter/ fresh air and exhaust feature
To remove, wash and replace filter and return air grille
Open the return air (RA) gille by grasping it at the top outside edges and
pulling towards you (see figure 5). The RA grille will stay open until it is
detached or closed. If you need to remove the RA grille, grasp it at the
bottom and pull towards you.
The filter is held in place by two spring clips (see figure 5). Push down on
the clips, _asp the filter and pull towards you to remove it for cleaning.
Clean with warm water and a mild detergent, rinse, dry completely and replace.
Use caution when removing the filter. The internal metal components are sharp.
If the RA grille has not been completely detached, close it by grasping it at
the top outside edges and pushing it towards the unit until it snaps shut.
If the RA gille has been removed, reposition it bottom first, while lining up
the control panel opening with the control panel itself (see figure 5). Once
it is lined up, push in at the bottom of the RA gille until you hear it snap
into place. Now close it by grasping the top outside edges and pushing it
towards the unit until it snaps shut.
Fresh air and exhaust control
Your air conditioner has the ability to bring fresh air into the room and
exhaust stale air out of the room. The control lever is found on the upper
part of the unit (see Figure 6).
TO BRING FRESH AIR IN – Move the lever to the FRESH AIR position which allows
outside air to enter the room.
This is useful in fall and spring as a means of bringing in fresh outside air
when using FAN ONLY. It can also be used in the summer with the compressor in
the Cooling Mode if you wish. Normally, for most efficient operation, cooling
is accomplished with this control in the middle or closed position.
TO EXHAUST INDOOR AIR – Move the lever to the EXHAUST position. This will
allow stale air to be expelled to the outside of the dwelling. This is
especially handy in the winter when indoor air tends to get stale, after a
social gathering involving smokers, or to remove odors after cooking.
Troubleshooting tips
Power failure
If you have a power failure, the unit’s auto-restart feature will resume
operation in the selected mode prior to the power failure
Won’t cool?
If your air conditioner operates, but won’t cool; check to see if the controls
are properly set. Check the filter and clean thoroughly if needed.
Won’t run?
Make sure the power cord is plugged in all the way. Check for a bad fuse or a
tripped breaker. This guide shows the proper fuse size on page 3. Lastly, you
can reset the circuit board by pressing the “MONEYSAVER” button and the
“FILTER ALERT” button at the same time. The LED (small red light) for the
Filter Alert will begin blinking.
Once this occurs, turn the unit off by pressing the On/Off button once and
then unplug the unit. Finally, plug the unit back in and turn it on by
pressing the On/Off button once.
All settings revert back to the factory default settings.
This is a warm weather appliance
Your air conditioner is designed to cool in warm weather when the outside
temperature is above 60°F (16°C), so it won’t cool a room if it is already
cool outside. If you want to cool a room in the winter, touch FAN ONLY and set
the FRESH AIR/EXHAUST control to FRESH AIR. This will bring in a supply of
outside air.
Condensation is normal
Air conditioners actually pump heat and humidity from your room to the outside
air. Humidity becomes water, and your air conditioner will use most of the
water to keep the outside
coil cool. If there is excessive humidity, there may be excess water that will
drip outside. This is normal operation.
Frosting
This usually occurs because of insufficient airflow across the coils, a dirty
filter, cool damp weather, or all of these.
Set unit to Fan Only and the frost will disappear. Setting the thermostat a
little warmer will probably prevent the frosting from recurring.
Noises
All air conditioners make some noise. We build them to operate as quietly as
possible. An air conditioner mounted in a wall is quieter than one mounted in
a window.
Cleaning your air conditioner
The decorative front and the cabinet can be cleaned with warm water and a mild
liquid detergent. The indoor coil can be vacuumed with a dusting attachment if
it appears to be dirty. The outdoor coil can be gently sprayed with a hose if
you can get to it. If not, you might call your dealer for a more thorough
cleaning when needed.
FRIEDRICH AIR CONDITIONING CO,
Post Office Box 1540 • San Antonio, Texas 78295-1540
[210) 357-4400 • FAX [210) 357-4480
ROOM AIR CONDITIONERS LIMITED WARRANTY
FIRST YEAR
ANY PART: If any part supplied by FRIEDRICH fails because of a defect in
workmanship or material within twelve months from date of original purchase,
FRIEDRICH will repair the product at no charge, provided room air conditioner
is reasonably accessible for service.
Any additional labor cost for removing inaccessible units and/or charges for
mileage related to travel by a Service Agency that exceeds 25 miles one way
will be the responsibility of the owner. This remedy is expressly agreed to be
the exclusive remedy within twelve months from the date of the original
purchase.
SECOND THROUGH FIFTH YEAR
SEALED REFRIGERANT SYSTEM: If the sealed refrigeration system (defined for
this purpose as the compressor, condenser coil, evaporator coil, reversing
valve, check valve, capillary, filter drier, and all interconnecting tubing)
supplied by FRIEDRICH in your Room Air Conditioner fails because of a defect
in workmanship or material within sixty months from date of purchase,
FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed
Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of
the problem, removal, freight charges and transportation of the air
conditioner to and from the Service Agency, and the reinstallation charges
associated with repair of the Sealed Refrigeration System. All such cost will
be the sole responsibility of the owner. This remedy is expressly agreed to be
the exclusive remedy within sixty months from the date of the original
purchase.
APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units
retained within the Fifty States of the U.S.A., District of Columbia, and
Canada. This warranty is not applicable to:
- Air filters or fuses.
- Products on which the model and serial numbers have been removed.
- Products which have defects or damage which results from improper installation, wiring, electrical current characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war, government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.
OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH
Authorized Deater or Service Organization in your area. They are listed in the
Yellow Pages. If assistance is required in obtaining warranty performance,
write to: Room Air Conditioner Service Manager, Friedrich Air Conditioning
Co., P.O. Box 1540, San Antonio, TX 78295-1540.
LIMITATIONS: THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything
in the warranty notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR
PARTICULAR PURPOSE AND/OR MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF
THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY
LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED
OR IMPLIED WARRANTY.
NOTE: Some states do not allow limitations on how long an implied
warranty lasts, or do not allow the limitation or exclusion of consequential
or incidental damages, so the foregoing exclusions and limitations may not
apply to you.
OTHER: This warranty gives you specific legal rights, and you may also have
other rights which vary from state to state.
PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive
any warranty related services.
All service calls for explaining the operation of this product will be the
sole responsibility of the consumer.
All warranty service must be provided by an Authorized FRIEDRICH Service
Agency, unless authorized by FRIEDRICH prior to repairs being made.
In case of questions regarding the provisions of this warranty, the English
version will govern.
Revised 08/01
FRIEDRICH AIR CONDITIONING CO.
Post Office Box 1540 • San Antonio, Texas 78295-1540
4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212
210-357-4400 • FAX
210-357-4480
www.friedrich.com
Printed in the U.S.A.
920-090-04(01-03)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>