FRIEDRICH MWM09Y1J Air Conditioning Instruction Manual
- June 17, 2024
- FRIEDRICH
Table of Contents
- Operation and maintenance
- Notices for use
- Names and functions of each part
- Operation of Remote Controller
- Remote Control Instructions
- Routine Maintenance
- Basic Troubleshooting
- Service & Assistance
- Installation
- Installation dimension diagram
- Install indoor unit
- Check after installation and test operation
- Documents / Resources
Installation and Operation Manual Models
Indoor Unit MWM09Y1J MWM12Y1J
Outdoor Unit MRM09Y1J MRM12Y1J
Operation and maintenance
This symbol stands for the items should be forbidden.
This symbol stands for the items should be followed
Thank you for choosing Friedrich Air Conditioning, please read this owner’s
manual carefully before operating the unit and keep it carefully for
consolation.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
Do not dispose of this product as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
Congratulations
Thank you for your decision to purchase Friedrich. Your new Friedrich has been
carefully engineered and manufactured to give you many years of dependable,
efficient operation, maintaining a comfortable temperature and humidity level.
Many extra features have been built into your unit to assure quiet operation,
the greatest circulation of cool, dry air, and the most economic operation.
General Instructions
This Installation and Operation Manual has been designed to insure maximum
satisfaction in the performance of your unit. For years of trouble-free
service, please follow the installation instructions closely. We cannot
overemphasize the importance of proper installation.
WARNING
Refrigeration system under high pressure
Do not puncture, heat, expose to flame or incinerate.
Only certified refrigeration technicians should service this equipment.
R410A systems operate at higher pressures than R22 equipment. Appropriate safe
service and handling practices must be used. Only use gauge sets designed for
use with R410A. Do not use standard R22 gauge sets.
Here are some suggestions to help you use your new Friedrich most efficiently:
- Carefully read and follow the installation instructions.
- Make sure the unit is the right capacity for the area being cooled. An undersized unit makes the unit work too hard, using more electricity than needed and increases wear. An oversized unit will cycle on and off too rapidly, and therefore cannot control humidity as well.
- Clean the filter frequently (See Routine Maintenance, Page 23).
- Do not block the air flow to and from the unit.
- A dirty filter or improperly set controls can affect the cooling ability of the unit.
- If cooling is weak and you have verified that the filter is clean and the controls are properly set, the unit may need service and you should call your Friedrich service provider to check the unit.
- Keep blinds, shades and drapes closed on the sunny side of the room being cooled to reduce radiant heat.
- Proper insulation helps your unit maintain the desired inside temperature.
- Whenever possible, shade south and west facing windows.
- Keep window coverings away from the unit to provide free air flow.
WARNING
Read Installation Operation Manual
Please read this manual thoroughly prior to equipment installation or
operation.
It is the installer’s responsibility to properly apply and install the
equipment. Installation must be in conformance with the NFPA 70 -2008 National
Electric Code or current edition, International Mechanic Code 2009 or current
edition and any other applicable local or national codes. Failure to do so can
result in property damage, personal injury or death.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your
appliance. Always read and obey all safety messages.
This is a safety Alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and
others.
All safety messages will follow the safety alert symbol with the word
“WARNING” or “CAUTION”. These words mean:
WARNING Indicates a hazard which, if not avoided, can result in severe
personal injury or death and damage to product or other property.
CAUTION
Indicates a hazard which, if not avoided, can result in personal injury and
damage to product or other property.
All safety messages will tell you what the potential hazard is, tell you how
to reduce the chance of injury, and tell you what will happen if the
instructions are not followed.
NOTICE
Indicates property damage can occur if instructions are not followed.
Notices for use
Working principle and special functions for cooling Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and
discharged, so that indoor ambient temperature decreased, its cooling capacity
will increase or decrease by outdoor ambient temperature.
Anti-freezing function:
If the unit is running in COOL mode and in low temperature, there will be
frost formed on the heat exchanger, when indoor heat exchanger temperature
decreased below 0 , the indoor unit microcomputer will stop compressor running
and protect the unit. ℃ Working principle and special functions for heating
Principle:
-
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase room temperature. This is the heat pump heating principle, its heating capacity will be reduced due to outdoor temperature decrease.
-
If outdoor temperature becomes very low, please operate with other heating equipments.
Defrosting: -
When outdoor temperature is low but high humidity, after a long while running, frost will form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting function will act, the heat running will stop for 8-10mins.
-
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
-
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor.
This is due to the defrosting, it isn’t malfunction.
After defrosting finished, the heating will recover automatically. -
Anti-cool wind function:
In “Heat” mode, under the following three kinds of state, if indoor heat exchanger doesn’t arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within 2 mins):- Heating starts. 2.After Auto Defrost finished. 3.Heating under the low temperature.
Gentle Breeze
In the following situation, the indoor unit may blow gentle breeze, and the
guide louver rotate to a certain position: .
- In “Heat” mode, the unit turned on, the compressor doesn’t arrive the starting condition
- In “Heat” mode, the temperature arrive at the setting value and the compressor stop running about 1min.
Notices for use
Working temperature range
| Indoor side DB/WB(ºF)| Outdoor side DB/WB(ºF)
Maximum cooling| 90/73| 109/79
Maximum heating| 81/—| 75/64
The operating temperature range (outdoor) heat pump unit is 5ºF~ 109ºF. 115V Model
Names and functions of each part
Operation of Remote Controller
-
Press to start or stop operation.
-
: Press to decrease temperature setting.
-
: Press to increase temperature setting.
-
FAN AUTO Press to set fan speed.
-
MODE
Press to select operation mode
(AUTO/COOL/DRY/FAN/HEAT). -
SENSOR
-
CLOCK
Press it set clock. -
TIMER ON
Press it to set auto-on timer. -
AIR SWEEP
Press it set swing angle. -
EXTEND
-
TEMP
-
TIMER OFF
Press it to set auto-off timer -
TURBO
SLEEP -
LIGHT
Press it to turn on/off the light. -
START / STOP
-
MODE icon:
If MODE button is pressed, current operation mode icon (AUTO), ( COOL), (DRY), (FAN) or (HEAT only for heat pump models) will show. -
SLEEP icon : is displayed by pressing the SLEEP button. Press this button again to clear the display.
-
TEMP icon: Pressing TEMP button, (set temperature), ambient temperature) (indoor ambient temperature) and blank is displayed circularly. (indoor is displayed when pressing icon:
-
AIR SWEEP the button. AIR SWEEP Press this button again to clear the display.
-
LIGHT icon: is displayed by pressing the LIGHT button. Press LIGHT button again to clear the display.
-
LOCK icon: is displayed by pressing “+” and “-” buttons simultaneously. Press them again to clear the display.
-
SET TIME display: After pressing TIMER button, ON or OFF will blink.This area will show the set time.
-
TURBO icon: is displayed when pressing the nottub siht sserP.nottub OBRUT again to clear the display.
-
DIGITAL display: This area will show the set temperature.
-
SENSOR icon: is displayed when pressing the to clear the display.
-
FAN SPEED display: Press FAN button to select the desired fan speed setting (AUTO- Low-Med-High).Your selection willbe displayed in the LCD windows, except the AUTO fan speed.
-
EXTEND icon: is displayed when pressing the EXTEND button. Press this button again to clear the display.
Remote Control Instructions
Remote Controller Description
-
START / STOP: Press this button to turn on the unit .Press this button again to turn off the unit.
-
Press this button to decrease set temperature. Hold it down for 2 seconds or more to rapidly decrease set temperature. In AUTO mode, set temperature is not adjustable.
-
Press this button to increase set temperature. Hold it down for 2 seconds or more to rapidly increase set temperature. In AUTO mode, set temperature is not adjustable.
-
FAN : This button is used for setting Fan Speed in the sequence that goes from AUTO, AUTO
-
MODE : Each time you press this button, a mode is selected in a sequence that goes from AUTO, COOL,DRY, FAN, and HEAT *, as the *following: Note:** Only for models with heating function.
After energization, AUTO mode is defaulted. In AUTO mode, the set temperature will not be displayed on the LCD, and the unit will automatically select the suitable operation mode in accordance with the room temperature to make indoor room comfortable. -
SENSOR (SAVE) :
Press this button to turn on SENSOR(SAVE) function. Saves room ambient temperature and automatically adjusts maintaining that room ambient until pressed again which cancels the SENSOR(SAVE) function. -
CLOCK : Pressing CLOCK button, blinks. Within 5 seconds , pressing + or – button adjusts the present time. Holding down either button above 2 seconds increases or decreases the time by 1 minute every 0.5 second and then by 10 minutes every 0.5 second. During blinking after setting, press CLOCK button again to confirm the setting, and then will be constantly displayed.
-
TIMER ON :
Press this button to initiate the auto-ON timer. To cancel the auto-timer program, simply press this button again.
After pressing this button, disappears and “ON “blinks . 00:00 is displayed for ON time setting. Within 5 seconds, press + or – button to adjust the time value. Every press of either button changes the time setting by 1 minute. Holding down either button rapidly changes the time setting by 1 minute and then 10 minutes. Within 5 seconds after setting, press TIMER ON button to confirm. -
AIR SWEEP: Press this button to set up & down swing angle, which circularly changes as below: This remote controller is universal. If any command , is sent out, the unit will carry out the command as indicates the guide louver swings as:
EXTEND(DRY):
Pressing button in COOL or DRY mode, the icon is displayed and the indoor EXTEND fan will continue operation for 10 min utes in order to dry the indoor unit even though you have turned off the unit. After energization, OFF is defaulted. is not available in AUTO, FAN or EXTEND EXTEND HEAT mode. -
TEMP:
By pressing this button you can display the indoor setting temperature or indoor ambient temperature.When the indoor unit is first powered on it will display the setting temperature, if the temperature’s display status is changed from other status to” 3)” displays the ambient temperature, 5s later or within 5s, it receives other remote control signal that will return to display the setting temperature. if the users haven’t set up the temperature displaying status,that will display the setting temperature.(This function is not applicable for some models). -
TIMER OFF : Press this button to initiate the auto-off timer. To cancel the auto-timer program, simply press the button again.
-
TIMER OFF setting is the same as TIMER ON.
-
TURBO: Press this button to activate / deactivate the Turbo function which enables the unit to reach the preset temperature in the shortest time. In COOL mode, the unit will blow strong cooling air at super high fan speed. In HEAT mode, the unit will blow strong heating air at super high fan speed. (This function is not applicable for some models).
-
SLEEP: Press this button to go into the SLEEP operation mode. Press it again to cancel this or DRY mode to maintain the most comfortable temperature for you. function. This function is available in COOL
-
LIGHT: Press LIGHT button to turn on the display’s light and press this button again to turn off the display’s light. If the light is turned on, is displayed. If the light is tunrned off , disappears.
-
Combination of “+” and “-” buttons: About lock Press “+ ” and “-” buttons simultaneously to lock or unlock the keypad. If the remote controller is locked, is displayed. In this case, pressing any button, blinks three times.
-
Combination of “MODE” and “-” buttons: Allows you to toggle between Fahrenheit and Celsius. ℃ ℉ , press “MODE” When the unit is OFF and ” – ” buttons simultaneously to switch between and .
Replacement of Batteries
- Remove the battery cover plate from the rear of the remote controller. (As shown in the figure)
- Take out the old batteries.
- Insert two new AAA1.5V dry batteries, and pay attention to the polarity (+/-).
- Reinstall the battery cover plate
★ Notes:
- When replacing the batteries, do not use old or different types of batteries, it may cause malfunction.
- If the remote controller will not be used for a long time, please remove batteries to prevent batteries from leaking. Diagram for removal of batteries
- Remote should be kept 3 feet away from the TV set or stereos. If the remote controller does not operate normally, remove batteries and reinsert after 30 seconds. If abnormal operation continues, replace the batteries.
Front Panel Illumination On/Off
Display indicator light control of indoor unit
- Display indicator light on: To turn ‘On’ the light function,the icon will display on the remote control screen by pressing the “Light” button. In which case,the display indicator light will be on if the unit receives this signal.
- Display indicator light off: To turn ‘Off ‘ the light function, the will disappear on the remote control screen by pressing this button. In which case, the display indicator light will be off if the unit receives this signal.
Emergency operation
If the wireless remote control is lost or broken, please use the manual switch
button. At this time, the unit will run in the. Auto mode, the temperature and
fan speed cannot be changed. The operation is shown below:
(Fig .3) Open front panel and the manual switch is on the rightside near
electrical connection cover.
-
Turn off the unit: Press manual switch to turn off unit.
Press manual button and unit will run in Auto mode immediately. The unit will adjust to the indoor temperature previously selected (Cooling or Fan) and obtain a comfortable setting. -
Turn off the unit: Press manual switch to turn off unit.
Routine Maintenance
Caution
Turn power off and pull out the power plug before cleaning air conditioner, or
it may cause electric shock.
Never spray water directly into indoor or outdoor components while power is
connected as electrocution or shock can occur.
Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner.
(Wipe the unit with a dry soft cloth, or a cloth slightly moistened with water
or cleanser.)
Cleaning the front panel
When cleaning the front panel, please dip the cloth into water with
temperature below 113ºF, then dry the cloth and wipe the front panel or dirty
portion of front.
Note: Do not immerse the front panel in water, there are PCB (electronic)
components and circuit diagrams on the front panel that may become damaged.
Clean the air filter (Recommended once every three months) the air filter
should be cleaned more frequently.
NOTE: If there is an excessive amount of dust around the air conditioner, to
moderate personal injury. Once filters are removed sharp. Failure to do so can
result in minor do not touch fins, edges may be
-
Removing air filter
on both sides of the front panel are slots pull front open, pull the air filter downward and take it out, please see the Fig. 4(a, b). -
Clean the air filter To clean the dust adhering to the filters, you can either use a vacuum cleaner, or wash them with warm water and neutral detergent (the water should be below 113ºF degree) ,and allow to dry. NOTE: Never use water above 113ºF to clean, or it can cause deformation or discoloration.
-
Reinsert the air filter
Reinsert the filters along the same location they had been removed from and snap front panel back into place.
Basic Troubleshooting
CAUTION
Don’t attempt to repair the air conditioner by yourself, it can cause an
electric shock or fire. Please check the following items before asking for
repair, it can save your time and money.
Complaint| Cause|
Soultion
---|---|---
Wireless Remote control does not work.| Not in frequency range| Remove
batteries and reinstall. Replace batteries.
There is water leaking into living space from indoor unit.| High humidity|
Humid conditions in living space. Condensate drain overflow.
Drain pipe to indoor unit is loose.
There is water leaking from outdoor unit.| Unit is running in cool mode Unit
is running in Auto defrost mode
Unit is running in Heat mode| Condensation may have formed on piping.
Ice may have formed and is defrosting into unit.
Condensation may have dripped off outdoor coil.
Noise from indoor unit.| Sound of fan Defrost of indoor coil| Sound can be
blower or motor please contact a service center if noise persists. Coil can
become frosted in some conditions and unit will cycle into a defrost sound may
be ice thawing inside. Once defrost is complete sound should not occur.
Indoor unit not blowing air| Unit is in Defrost mode.| Unit may have switched
off for outdoor coil to defrost in low ambient conditions function will
resume.
Moisture on air vent| High Humidity| Condensation may have formed and dripped
off grille due to extended cooling.
Complaint| Cause| Solution
---|---|---
Wireless Remote control does not work.| •Not in frequency range| •Remove
battenes and reinstall.
•Replace batteries.
There is water leaking into living space from indoor unit.| •High humidit y|
•Humid conditions in living space.
•Condensate drain overflow.
•Drain pipe to indoor unit is loose.
There is water leaking from outdoor unit.| •Unit is running in cool mode
•Unit is running in Auto defrost mode
•Unit is running in Heat mode| •Condensation may have formed on piping.
•Ice may have formed and is defrosting into unit.
•Condensation may have dripped off outdoor cod.
Noise from indoor unit.| •Sound of fan
•Defrost of indoor coil| •Sound can be blower or motor please contact a
service center if noise persists.
•C011 can become frosted in some conditions and unit will cycle into a defrost
sound may be ice thawing inside. Once defrost is complete sound should not
occur.
Indoor unit not blowing air| •Unit is in Defrost mode.| •Unit may have
switched off for outdoor coil to defrost in low ambient conditions function
will resume.
Moisture on air vent| •High Humidity| Condensation may have formed and dripped
off grille due to extended cooling.
Immediately stop all operations and plug out, contact the dealer if following
situations occur.
There is harsh sound during operation.
There unusual and offending odors emitted during operation.
Water is leaking in the room.
Breaker or Time delay fuse often trips.
Accidentally splashed water or other liquids into unit.
There is excessive or abnormal heat emanating from the power cords.
Turn off unit and switch off breaker.
Service & Assistance
Before calling for service, please check the “Basic troubleshooting” section above. This may help you to find the answer to your problem, avoid unnecessary service calls, and save the cost of a service call if the problem is not due to the product itself. If you have checked the “Basic troubleshooting” section and still need help, below you will find a list of available services:
- You can find the name of your local Authorized Service Provider by visiting our website at www.friedrich.com.
- lf you require further assistance please call Friedrich customer support at 1-800-541-6645.
- Before calling please make sure that you have the full model and serial number, as well as the date of purchase of you equipment available. Providing us with this information will allow us to better assist you.
Our specialists are able to assist you with:
* Specifications and Features of our equipment
- Referrals to dealers, and distributors.
- Use and Care information
- Recommended maintenance procedures
- Installation information
- Referrals to Authorized Service Providers and Parts depots.
Installation
Important Notices
Indoor Unit Placement
- Air inlet and discharge should be kept free of obstruction at all times. Ensure airflow through living space.
- Condensate should drain easily from unit.
- Keep system out of the reach of children and pets.
- Installation choice should be strong enough to handle the weight of the equipment and insulate against vibration noise from operation.
- Be sure to leave enough space to allow access for routine maintenance. The height of the installed location should be 8 ft or more from the floor.
- Select a place 3 ft or more away from TV or any other electric appliances.
- Select a place where the filter can be easily taken out.
- Follow installation requirements and dimensions.
- Do not use the unit in the immediate surroundings of a laundry, bath, shower or swimming pool
Outdoor Unit Placement
- Select a location with consideration of surroundings including pets and neighbors as heat and cool will be discharged from equipment.
- Select a location where there should be sufficient ventilation.
- Select a location where there should be no obstructions cover the inlet and outlet.
- The location should be able to withstand the full weight and vibration of the outdoor unit and permit safe installation.
- Select a dry place, but do not expose under the direct sunlight or strong wind.
- Make sure that the outdoor unit installation dimension with installation are in accordance dimension diagram, convenient for maintenance, repair. tubing within . 33 ft
- The height difference of connecting the tubing within 16 ft , the length of connecting the
- Select a place where it is out of reach for the children.
- Select a place where will not block the passage and do not influence the city appearance.
Notices for installation
Outdoor Unit Installation Position Selection
- Consideration should be made in location of outdoor unit as heat/cool is emitted, pets and neighbors could be affected by this.
- Select a location where there should be sufficient ventilation.
- Select a location where there should be no obstructions to cover the inlet and outlet.
- The location should be able to withstand the full weight and vibration of the outdoor unit and permit safe installation.
- Select a dry place, but do not expose under the direct sunlight or strong wind.
- Installation should follow instructions and dimensions.
Safety Requirements For Electric Appliances
-
Ensure that power circuit is dedicated and not shared with other equipment.
Power cable diameter should be followed. -
Do not damage power cord.
-
The breaker switch must have the functions of magnetic tripping and heat tripping, in order to protect from short circuit.
-
Keep system 5 feet from combustibles.
-
Be sure to follow local and national electrical code.
Note:
Follow wiring diagram to ensure that short circuit will not happen. Incorrect wiring can cause potential for fire.
Installation dimension diagram
Install indoor unit
Install the rear panel
- Always mount the rear panel horizontally. Due to the condensate tray inside the indoor unit, the outlet side of the pan should have a slight tilt to assist in the gravity draining of the water in the pan. The angel between the evaporator and level should ne 0 or more. This will assist with drainage.
- Fix the rear panel on the wall with screws.
- Be sure that the rear panel has been secured firmly enough to withstand the weight of an adult of 130lbs.
Install the piping hole
- Make the piping hole (Ф2 1/2″) in the wall at a slight downward slant to the outdoor side.
- Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole.
Install the water drainage pipe
- For well draining, the drain hose should be placed at a downward slant.
- Do not wrench or bend the drain hose, overflow can occur.
- If routing the condensate drain with piping, wrap with insulation.
Connect indoor and outdoor electric wires
- Open the front panel.
- Remove the wiring cover and wire clamp. Make the power connection cord pass through the hole at the back of indoor unit.
- Connect and fix the power connection cord to the terminal board.
- Fix the power connection cord with wire clamp and reinstall wiring cover.
- Reinstall the front panel.
NOTE:
Do not splice electrical wire together if too short, purchase new wire of
correct length to install. otherwise communication errors can occur.
- The wiring must be correctly connected, improper wiring can cause malfunction.
- Tighten terminal firmly to ensure wiring will not come loose, but do not over tighen as damage to terminal can occur.
- Ensure ground wire is connected properly otherwise electrical hazard can occur.
- The cover plate must be installed if poorly installed dust and moisture may enter or the terminal will be affected by the outside environment, and will cause fire or electric shock.
Install the indoor unit
The piping can be lead out from right, right rear, left left rear.
-
When routing the piping and wiring from the left or right side of indoor unit, cut off the tailings from the chassis in necessary(Show in Fig.6)
(1)Cut off the tailings 1 when routing the wiring only; (2)Cut off the tailings 1 and tailings 2 when routing both the wiring and piping. -
Take out the piping from body case, wrap the piping electric wire, water pipe with tape and pull them through the piping hole (As show in Fig.7 )
-
Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough.(As show in Fig.8)
-
The height of the installed location should be 8ft or more from floor.
Install the connection pipe
- Align the center of the piping flare with the relevant valve.
- Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to the following:
Hex nut diameter | Tightening torque (lb.ft) |
---|---|
Ф6 | 11~14.7 |
Ф 9.52 | 22.8~25.8 |
Ф 12 | 36.9~40.6 |
Ф 16 | 44.3~47.9 |
Ф 19 | 51.6~55.3 |
NOTE: Connect indoor piping first, then take care bending pipe to outdoor
unit, then install piping there. Do not over tighten the flares as leaks can
occur.
Electrical wiring
- Remove the cover on right side of outdoor unit.
- Take off wire clamp. Connect and fix the power connection cord to the terminal board. Wiring should be sized for indoor unit too.
- Fix the power connection cord with wire clamp.
- Confirm if the wire has been tighend properly.
- Reinstall terminal cover. NOTE:
Incorrect wiring may cause malfunction of parts.
After the wire has been fixed, ensure that no wires will contact others.
Air purging and leakage test
- Connect charging hose of manifold valve to charge end of low pressure valve (both high/low pressure valves must be tightly shut).
- Connect joint of charging hose to vacuum pump.
- Fully open handle handle of Lo manifold valve.
- Open the vacuum pump to evacuate. At the beginning, slightly loosen joint nut of low pressure valve to check if there is air coming inside. (If noise of vacuum pump has been changed, the reading of multimeter is 0) Then tighten the nut.
- Keep evacuating for more than 15 mins and make sure the reading of multi-meter 500 Microns and holding.
- Fully open high/low pressure valves.
- Remove charging hose from charging end of low pressure valve.
- Tighten bonnet of low-pressure valve. (As shown in Fig.9)
Condensate drainage of outdoor unit (no for cooling only)
The condensate and defrosting water formd during heating Ø in the outdoor unit
can be properly discharged by drainage pipe .
Installation method: set the drain connection in 25 hole of the chassis has
been installed and then connect drainage pipe with drain nozzle, so that
condensate and defrosting waer can be properly discharged
Check after installation and test operation
Check after installation
Items to be checked | Possible malfunction |
---|---|
Is unit installed correctly? | Unit may fall, shake or create excessive noise. |
Have you done the refrigerant leakage test? | system of refriwill no gerant can |
occur and t cool.
Is equipment insulated properly?| It may cause condensation and dripping.
Is water drainage good?| It may cause condensation and dripping.
Is supply voltage in accordance with the rated voltage marked on the
nameplate?| It may cause electric malfunction or damage the part.
Is the electric wiring and piping connection installed correctly and
securely?| It may cause electric malfunction or damage the part.
Has the unit been connected to a secure ground connection?| It may cause
electrical leakage.
Is the power cord sized correctly?| It may cause electric malfunction or
damage the part.
Has the air dicharge and inlet been covered?| It may cause insufficient
cooling(heating) capacity.
Has the length of connection pipes and refrigerant capacity been recorded?|
The refrigerant capacity is not accurate.
Test Operation
-
Before test operation
(1) Do not switch on power before installation is finished completely.
(2) Electric wiring must be connected correctly and securely.
(3) Cut-off valves of the connection pipes should be opened.
(4) All scraps and waste fron installation have been removed? -
Test operation method
(1) Switch on power, press “ON/OFF” button on the wireless remote control to start the operation.
All scraps and waste fron installation have been removed?
(2) Press MODE button, to select the COOL, HEAT, FAN to check whether the operation is normal or not.
Friedrich Air Conditioning Co.
10001 Reunion Place, Suite 500
San Antonio, Texas 78216
1.800.541.6645
www.friedrich.com
Documents / Resources
|
FRIEDRICH MWM09Y1J Air
Conditioning
[pdf] Instruction Manual
MWM09Y1J, MWM12Y1J, MRM09Y1J, MRM12Y1J, MWM09Y1J Air Conditioning, MWM09Y1J,
Air Conditioning, Conditioning
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>