NEUTRIK NE8FDPS-TOP EtherCON Airtight Instruction Manual

June 17, 2024
NEUTRIK

NE8FDPS-TOP EtherCON Airtight

PRODUCT MANUAL
Example (NE8FDPS-TOP) of
preassembled Delivery.
etherCON® TOP airtight
NE8FDPS-TOP & NE8FDIS-TOP & NE8FDPU-TOP

Example of etherCON TOP Unmated connection options

flange

1 Connector installation

connector installation

Step 1: Combine connector parts
A Combine flange and sealing cap

PRODUCT MANUAL – etherCON TOP airtight ® chassis connector

Step 2: Assembly

B Insert the receptacle from the front into the panel.
C Position the screw and fasten it.

D ATTENTION :
Tightening torque MA = 40 – 50 Ncm

N O T E : L u b r i c a t e s e a l i n g l i p w i t h
s i l i c o n f r o m t i m e t o t i m e .

2 Additional information

rear side

PRODUCT MANUAL – etherCON® TOP airtight chassis connector

3 Application and Safety Instructions

A Assembly

  • When assembling and processing the product, ensure the use of appropriate personal
    protective equipment.

  • Neutrik components must only be assembled with designated and specified components.

  • Replacement parts are suitable only when used in combination with the designated
    components. The product’s characteristics are guaranteed only in the intended combination.

B Application

  • The product is exclusively intended for installation in electronic equipment or similar devices.
  • The product is not intended for use in medical applications.
  • The product is not intended for use in potentially explosive or flammable environments.

C Operation

  • Before plugging in, check the contact area for dry surfaces.

  • Product surfaces may cause burns at elevated ambient temperatures. Ensure the use of appropriate
    protective equipment.

  • Neutrik products should only be combined with products from Neutrik Group brands.

D Cleaning

  • Clean only with dry and lint-free materials or compressed air.
  • The product must not be cleaned while under load. The product may only be cleaned while it is not
    connected to any voltage and without the use of cleaning agents.

E Damages

Data subject to change without prior notice. 2023 NEUTRIK . NEUTRIK are registered trademark of Neutrik AG. © ® ® ALL RIGHTS RESERVED.

Document No.: BDA 692 V1
Date: 2023-12-04

Neutrik AG I LI-9494 Schaan