NEUTRIK NA3FP Adapter XLR 3pol to tele 6.3 mm Straight User Guide
- June 9, 2024
- NEUTRIK
Table of Contents
- NEUTRIK NA3FP Adapter XLR 3pol to tele 6.3 mm Straight
- Accessories
- Patch Panels
- Circular Adapters
- Ordering Information
- AES / EBU Digital Impedance Transformer Adapters
- Technical Data
- Ordering Information
- Modules & Audio Transformer
- Module Selection Guide
- Ordering Information
- superior quality
- NPPA Series
- Bantam Patch Panels
- Long frame B-Gauge Patch Panels
- Technical Data
- Ordering Information
- Definitions, Abbreviations & Useful Information
- Part Number Guide
- Neutrik ® Product Line
- ASSOCIATED COMPANIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NEUTRIK NA3FP Adapter XLR 3pol to tele 6.3 mm Straight
Accessories
Patch Panels
Introduction
Various connector standards in the professional and semi-professional audio
and video world lead to many interconnection challenges.
Neutrik has made it a rule to serve our customers’ needs in all its connector
offerings and has therefore produced a variety of problem solvers.
With our adapter series we have a solution for the most known interconnection
difficulties and in addition we offer modules for the most common connector
types to fulfill more specific needs.
Miniature impedance balancing adapters are the answer to the most common noise
and grounding problems and for customized designs we recommend our proven
audio transformers in combination with our modules.
Neutrik offers a wide range of audio adapters, transformers, AES / EBU
adapters and gooseneck products. From problem solvers to connection quick
fixes, Neutrik has the most popular audio connectivity solutions. All Neutrik
adapters and connectors are soldered with lead free RoHS compliant solder.
Adapter
Circular Adapters
- Variety of adapters offered to interface with most connector combinations
- Professional look and compact space saving design
- Rugged diecast shell for best reliability
- Compact design and durability with Neutrik quality
Adapter
Circular Adapters
- Neutrik speak ON NL4FC with 1/4” mono jack (Wiring: +1 to TIP and -1 to SLEEVE)
- Versatile, pre-wired and ready to use adapters to reliably interlock various connector systems
- Based on the XX Series
Adapter
D Shape Adapters
- Problem solvers for various intermating problems for professional and semi-professional applications
- Rugged aluminum extrusion housings for best reliability
- Color coding on all RCA types
Miniature transformer balancing adapters NA2*-TX
- Audio Transformer 1:1 impedance ratio 200:200
- Low cost solution for unbalanced / balanced line conversion and passive DI applications, where no earth or gain switching is required.
- Source / Load impedance 600 / 10 K Max. input level @ 50 Hz at 1% THD: -3 dBu
Adapter
D Shape Adapters
-
Miniature transformer balancing adapter
-
power CON NAC3MM-1:
NAC3MPA-1 (power in) – power CON NAC3MPB-1 (power out), coupler for linking cables -
8 pole speak ON feedthrough adapter for cable extensions
Ordering Information
Cir cular Adapters|
---|---
| |
Part No. Port 1| Port 2| Comments
| |
NA2FBNC 3 pole XLR female| BNC socket| 1)
NA2FP 3 pole XLR female| TS 2),1/4″ plug| 1)
NA2FPMF 3 pole XLR female| RCA / phono socket| 1)
NA2FPMM 3 pole XLR female| RCA / phono plug| 1)
NA2MBNC 3 pole XLR male| BNC socket| 1)
NA2MP 3 pole XLR male| TS 2),1/4″ plug| 1)
NA2MPMF 3 pole XLR male| RCA / phono socket| 1)
NA2MPMM 3 pole XLR male| RCA / phono plug| 1)
NA3FF 3 pole XLR female| 3 pole XLR female| gender
conversion adapter
NA3FF-B 3 pole XLR female| 3 pole XLR female|
gender conversion, black plating
NA3FJ 3 pole XLR female| TRS 2),1/4″ jack| locking
jack
NA3FM 3 pole XLR female| 3 pole XLR male| extention
adapter
NA3FMX 3 pole XLR female| 3 pole XLR male| contacts 2
– 3 inverted
NA3FP 3 pole XLR female| TRS 2), 1/4″ plug|
NA2JJ mono 1/4″ jack| TS 2), 1/4″ jack| extension
adapter
NA3JJ stereo 1/4″ jack| TRS 2), 1/4″ jack|
extension adapter, locking jack
NA3MJ 3 pole XLR male| TRS 2), 1/4″ jack| locking
jack
NA3MM 3 pole XLR male| 3 pole XLR male| gender
conversion adapter
NA3MM-B 3 pole XLR male| 3 pole XLR male| gender
conversion, black plating
NA3MP 3 pole XLR male| TRS 2),1/4″ plug|
NA5FF 5 pole XLR female| 5 pole XLR female| gender
conversion adapter
NA5FF-B 5 pole XLR female| 5 pole XLR female|
gender conversion adapter, black plating
NA5MM 5 pole XLR male| 5 pole XLR male| gender
conversion adapter
NA5MM-B 5 pole XLR male| 5 pole XLR male| gender
conversion adapter, black plating
NA4FX-F speakON NL4FX| 3 pole XLR female| speaker
adapter 3)
NA4FX-M speakON NL4FX| 3 pole XLR male| speaker
adapter 3)
NA4LJX speakON NL4FX| TS 2), 1/4″ jack| speaker
adapter 3)
NL4MMX 4 pole speakON| 4 pole speakON| lockable
coupler 5)
| |
D Shape Adapters| |
| |
NA2BBNC-D4B BNC socket| RCA / phono socket| colour coded
yellow
NA2BBNC-D9B BNC socket| RCA / phono socket| colour coded
white
NA2F-D0B-TX 3 pole XLR female| RCA / phono socket| colour
coded black 4)
NA2F-D2B-TX 3 pole XLR female| RCA / phono socket| colour
coded red 4)
NA2F-J-TX 3 pole XLR female| 1/4″ jack| ground lifted
4)
NA2M-D0B-TX 3 pole XLR male| RCA / phono socket| colour
coded black 4)
NA2M-D2B-TX 3 pole XLR male| RCA / phono socket| colour
coded red 4)
NA2M-J-TX 3 pole XLR male| 1/4″ jack| ground lifted 4)
NE8FF etherCON etherCON| RJ45 coupler|
NL8MM 8 pole speakON| 8 pole speakON| lockable
coupler
NAC3MM-1 3 pole powerCON| 3 pole powerCON| lockable
coupler
NA4MP-F speakON NL4MP| 3 pole XLR female| speaker
adapter 3)
NA4MP-J speakON NL4MP| TS 2), 1/4″ jack| speaker
adapter 3)
NA4MP-M speakON NL4MP| 3 pole XLR male| speaker
adapter 3)
NA4MP-M-X speak ON NL4MP| speak ON NL4MP| speaker
adapter 1+ / 1- inverted 3)
- Wired according to IEC 268-12: pin 2 = signal, pin 1 and 3: connected to ground
- TRS-Tip, Ring, Sleeve contact (stereo); TS-Tip, Sleeve contact (mono)
- Detailed wiring info on www.neutrik.com
- Unbalanced / balanced line conversion, 1:1 transformer 200 Ω : 200 Ω
- speak ON is NOT to be used as an AC mains or power supply connector!
Adapter
AES / EBU Digital Impedance Transformer Adapters
-
Cost effective exceptional impedance matching adapters
Allow long cable runs for digital audio signals via low attenuation coax lines -
Match balanced (110 Ω) to coaxial lines (75 Ω)
-
Pre-wired in black anodized aluminum extrusions for increased durability
-
AES/EBU adapters available with either 3 pin male or female XLR cable ends or receptacles
-
Simple use, passive units
Technical Data
- Maximum voltage / Max. power: 5 Vp-p / 250 mW
- Frequency band: 0.1 MHz to 6 MHz
- Insertion loss: < 0.3 dB @ 0.1 MHz to 10 MHz
- VSWR / Return loss: < 1.1 / > 26.4 dB
Ordering Information
Adapter
- Compact XLR 3 to 5 pole adapters for lighting (DMX) applications
- Solve interconnection problems of the old (3-pole) and new (5 pole) DMX standard
- Enable usage of standard 3 pole microphone cable for DMX applications
- Based on the worldwide accepted standard XLR connectors
- Reliable and rugged diecast shell
Or dering Information
Part No.| Port 1| Port 2| Comments
NA3F5M| 3 pole XLR female| 5 pole XLR male| for DMX lighting applications
- NA3M5F
- 3 pole XLR male
- 5 pole XLR female
- for DMX lighting applications
Adapter
Feedthrough
- 3 pole XLR feedthrough adapter
- D-flange chassis mount
- Male to female and vice versa
- Utilizes XX-components
Ordering Information
NA3FDM | 3 pole XLR female | 3 pole XLR male |
---|---|---|
NA3MDF | 3 pole XLR male | 3 pole XLR female |
Adapter
etherCON ® Feedthrough & CAT6A Adapter
- Accommodates NE8MC* or any standard RJ45 plug
- NE8FF coupler (adapter) for cable to cable mating – use with NE8MC carriers or any standard RJ45 plug
- Approved latch lock system
- Ruggedized coupler with CAT6A component compliance according to ISO/IEC 11801 and TIA/EIA 568-C.2
- IP65 protected when mated with NE8MX6*
- Accommodates standard RJ45 plugs
- Revolutionary small form factor
- The adapter offers the million fold proven robust latch lock system
- Problem solver for various intermating problems for professional and semi-professional applications
Modules & Audio Transformer
Modules & Audio Transformers
- Multifunctional modules allow to design customized adapters to suit specific needs
- Based on the X and D Series connector system
- NTE transformers and switch can be built in
- Professional look, rugged diecast shell
Audio Transformer
- Professional audio transformers for multiple applications, as e.g. microphone or line inputs
- Very low distortion, excellent frequency response
- Cost effective cable version for free wiring
- Fully perm alloy-shielded studio versions
Audio Transformer selection Guide
Part No.| Turns Ratio (prim : sec)| Impedance ratio| Source / load impedance
in W| Max. Input level* @ 50 Hz, 1% THD [dBu]| Applications|
NTE1| 1 : 1| 200 : 200| 200 / 2k, (600 / 10k)| -3| General purpose, splitting,
XLR inline|
NTE4| 1 : 4| 200 : 3.2k| 200 / 10 K| -7| Mic input step-up
---|---|---|---|---|---
NTE10/3| 1 : 3| 200 : 1.8k| 200 / 10 K| -7| General purpose mic input step-up
| 1 : 10| 200 : 20k| 200 / 50 K| -6|
NTL1| 1 : 1| 10k : 10k| 600 / 10k| +19| Line input
NTM1| 1 : 1| 200 : 200| 200 / 2k| +7| Mic input, splitting
NTM4| 1 : 4| 200 : 3.2k| 200 / 10k| +9| Mic input step-up
- : measured with typical source / load impedances
Wiring: NTE: free wires, NTL / NTM… PCB mount, shielded; Find detailed specifications on www.neutrik.com
Module Selection Guide
Connector module Coupler / housing Transformer / switch
Goosenecks
Goosenecks
- For flexible and secure mounting of microphones, lamps etc.
- Versatile, modular system allows various combinations
- Durable stainless steel spiral, no rust, no noise, non-reflective black finish
- Theft proof microphone connection on GNS version (securing ring and fixing screw)
- Strong, flexible and noiseless goosenecks available in three lengths
Ordering Information
- Find detailed specifications on www.neutrik.com
GNS Set consisting of:
Patch Panels
Introduction
Patch Panels are central switching gears between audio equipments. They are
used to switch and route analog and digital audio signals from and to
equipments in recording or broadcast studios, OB vans, churches, theatres,
stadiums, arenas, etc.
Neutrik® Patch Panels are available in a varety of jack types, wiring and
grounding possibilities.
Common versions accommodating Bantam TT, 1/4“ A-gauge and longframe B-gauge
jacks on the front rows are available.
The mechanical size is designed to fit into 1U 19“ standard racks. All Neutrik
patch panels offer various norm Alling possibilities between top and bottom
row.
All Neutrik® Patch Panels are able to handle digital audio signals acc. AES3,
48kHz sampling rate.
superior quality
Audio Normalling
Audio Normalling is used within audio patch panels and is a wiring pattern in
which a circuit path is established from one piece of audio equipment to
another without the use of a patch cord. This pattern is then considered to be
the “normal” circuit path that is desired most of the time. If a patch cord is
inserted, the normal circuit path is interrupted and rerouted to a different
circuit path.
Normalled patch panels are most commonly found in vertical jack pairs: the top
jack is designated as the source and the bottom jack is the destination.
Normalling example: HALF NORMALLED BOTTOM ROW
This is the most common configuration, very often called HALF NORMALLED. In
this configuration internal norm Alling contacts connect the top jack contact
with the corresponding bottom jack contact. Inserting a plug in the bottom
jack will interrupt this internal norm Alling connection, while inserting a
patch cord into the top jack doesn‘t interrupt the circuit. (Can be used to
monitor the norm Alling circuit)
Other versions of norm Alling include Half Nonmilled Top Row, Full Nonmilled,
Parallel and Isolated.
NPPA Series
NPPA-Series – 96 Bantam (TT) Jacks
- Innovative and compact patching system (just 1U high) for 19“ rack mounting
- Robustly housed in a black coated steel shell
- Features 2 x 48 long life gold plated TT size (bantam) Neutrik NJ3TTA double contact point TRS jacks
- Available in all common norm Alling configurations (default Half Nonmilled Bottom)
- Qualified for analog and digital signals according to AES3, 48 kHz sampling frequency
- Remove the front panel for quick changes of the NJ3TTA-** modules for reconfiguration or repair even when “on air”
- Includes two built-in cable bars and two wide channel ID strips
- PatchLink Software for printing onto labeling strips on Neutrik website (available for PC only)
Dimensional Drawing
Design Criteria
All NPPA patch panels are fitted with high quality, long life NJ3TTA gold plated double contact jacks (2×48), featuring best contact integrity. The unit, robustly housed in a black coated steel shell, is finished off with a built in cable bar and two large channel identification strips for perfect management of the system. The NPPA patch panels are an innovative and compact patching system (just 1U high) for 19″ rack mounting.
Configuration
The standard version of the NPPA Panel is delivered bottom row half normalled for each jack pair by default. Further patch ver-sions are available with fully loaded jack-pairs as:
- Full Normalled
- Half Normalled
- Isolated
- Parallel
For individual normalling single pre-configured jack-pairs are offered.
NPPA-TT-IDC is equipped with jumper blocks for individual switching
configurations of each jack channel.
Note: Take care when handling digital signals. Do not use parallel
configuration and avoid other parallel paths when using half normalled
configurations. Parallel paths may lead to mismatching.
Grounding
The flexible grounding system provides the following versions:
- Individual: Each channel is individually grounded by its corresponding cable shield (default configuration).
- Group: Selected channel grounds are connected via the ground bus on the PCB using solder bridges and track cuts to form a group that is connected to one common cable shield.
- Central: All channel grounds (individual top and bottom row) are connected via the ground bus on the PCB using solder bridges and wired with only one cable shield.
- Chassis-Common: The same as central grounding but with the addition of the common ground bus (top and / or bottom rows) connected to the patch panel chassis by means of jumpers
Wiring Terminations
TT patch panels offer different choices of wiring:
- Spring loaded push terminals
- 56 pin Elco/Edac male connectors
- 90 pin Elco/Edac connectors
- 50 pin D-SUB connectors
- 25 pin D-SUB connectors
- IDC-Krone terminals
- Solder lugs
The spring loaded terminal blocks enable fast and easy wiring. No soldering and screwing necessary. Simply insert the stripped wire after pressing down the white key. Terminals accommodate stranded wires up to AWG 20 (0.5 mm2) and solid wires up to AWG 18 (0.75 mm2). Push terminals are gas tight connections.
For Pin assignment of ELCO / EDAC and D-SUB connectors please see drawings on www.neutrik.com
NPP-TB Series
NPP-TB-Series – 48 B-Gauge Jacks
- Features 2 x 24 Neutrik® NJ6TB-V long frame 1/4” TRS jacks according to BPO316/MIL-P-642/2
- Very robust and compact galvanized metal housing
- Compact, cost effective system qualified for both analog and digital signals acc. AES3, 48 kHz sampling frequency
- High quality long life gold plated Neutrik jacks
- Easily programmable for any of 6 configurations with 4 grounding choices
- Rear terminations include solderless terminal blocks or solder lugs (solder for non-programmable half-nonmilled versions only).
- Center marking strip is removable; See Neutrik website to download PatchLink labeling software for PCs
- Color coded tabs, dust cover and rear extension strain relief bars are optional accessories
Dimensional Drawing
Design Criteria
The NPP-TB patch panels are equipped with gold plated, high quality long life NJ6TB-V Jacks for BPO/MIL style plugs. The panels are easily programmable for six switching configurations and offer a flexible grounding system. The NPP-TB patch panels are very robust and compactly designed for 19″ rack mount (19″ x 1U) with galvanized metal housing and a built-in cable bar on the rear for securing wires. There is a rear extension bar (NPP-S) available as an option. On the front side there is an attractive additional lettering area for each channel pair with a marking strip and individual snapon color coding plates.
Configuration
Due to the jumper blocks capability provided, the switching configurations available per jack channel are:
- Half Normalled Bottom Row
- Full Normalled
- Parallel
- Isolated
The TB Panel is delivered in a full nonmilled configuration for each jack
channel. A non-configurable half nonmilled (“-HN”) bottom row version with
solder lugs is also avail-able.
NOTE: Take care when handling digital signals. Do not use Parallel
configuration and avoid other parallel paths with Half / Double Nonmilled
configurations. Parallel paths may lead to mismatching.
Grounding
The flexible grounding system allows four possibilities to fit your needs:
- Individual: Each channel ground is separately connected with the corresponding cable shield (default configuration).
- Group: Some channel grounds are PCB connected by making soldering joints on the PCB and by cutting tracks respectively to form a group that is connected to one common cable shield.
- Central: All channel grounds are PCB connected by making soldering joints and wired with only one cable shield.
- Chassis-Common: Same as central grounding with additional connection of the common ground to the Patch Panel chassis by means of a jumper.
Wiring Terminations
TB patch panels are available with:
- Spring loaded push terminals (NPP-TB)
- Solder lugs (NPP-TB-HN)
The spring loaded terminal blocks are fast and easy to connect and disconnect
the wires.
No soldering and screwing necessary. Simply insert the stripped wire after
pressing down the white key.
Accommodates stranded wires up to AWG 20 (0.5 mm2) and solid wires up to AWG
18 (0.75 mm2).
NYS Series
1/4″ Patch Panel
- Individual grounding available for each channel separately
- Ruggedized metal housing
- Improved contact design minimizes wear on mated plugs
- Economic and versatile designed 1/4″ modular patch panel with 2 rows of jack sockets
- 48 balanced channels with fully PCB wired jack (24 vertical PC boards), 24 front pairs and corresponding 24 rear pairs
- Jack PC card contains 4 balanced 1/4″ jacks with non-tarnishing contacts, is held securely in place without the use of nuts -no little pieces to drop, break or lose
- Easy to change configuration by just flipping individual PC board
- Norm Alling jack is cultured grey for easy identification
- 4 designation strips included for front and rear panel
Dimensional Drawing
Design Criteria
The NYS-SPP-L1 is a economical and remarkable sleek designed 1/4“ modular
patch panel for 19“ rack mount (19“ x 1U) with a reinforced metal housing.
Each of it‘s 48 PCB wired balanced channels (24 front pairs and corresponding
24 rear pairs) can either be grounded separately or in groups of individually
choose able channel numbers (detailed information see below).
The PCBs are held securely in place by being clamped between the front and the rear panel, this grants an easy reconfiguration of the patch panel without the danger of loosing any small parts (e.g. nuts). The grey jack serves as an easy and distinguishable norm Alling identification.
Configuration
Standard configuration, when delivered, is Half Nonmilled bottom row. The
configuration can easily be changed by just flipping the individual PCB.
Inserting a plug into the grey jack will always isolate the top against the
bottom row. Alternative solution for send / return applications by use of NYS-
SPCR1 module (see accessories below).
Grounding
The flexible grounding system, applicable for each channel separately by
simply attaching the loose supplied grounding clips to the grounding pad of
the corresponding channel, offers the following alternatives:
- Individual (without grounding clip): Each channel ground (sleeve contact) is connected to the dedicated ground contact of the incoming 1/4” plug only. This is the standard configuration for delivery.
- Chassis common : The relevant channel grounds (sleeve contacts; top and bottom row) is connected to the ground flat tab via grounding clip and chassis.
- Chassis top : The dedicated top channel ground (sleeve contact) is connected to the ground flat tab via grounding clip and chassis.
- Chassis bottom : The dedicated bottom channel ground (sleeve contact) is connected to the ground flat tab via grounding clip and chassis.
Bantam Patch Panels
MA 96 and XPM 96 Bantam Patch bays
- Robust designed patch bay to accept standard 4.4 mm Bantam jack connectors (acc. MIL-D-642/13)
- Fitted with 96 Rein die-cast jack sockets
- Constructed from rigid aluminum extrusion which includes 2 integral slots for designation strips
- 96 channels grouped in two row 12 x 8 stereo jacks
- XPM96 features traditional 2 row, 4 x 24 stereo jacks
- Available in 4 colors: black, silver, red or blue
- Suitable for audio, broadcast, data and industrial applications XPM96
Dimensional Drawing
Bantam Patch Panels
MAJ 501 Bantam Jack Socket
- 5-point Bantam jack socket (Tip, Ring, Sleeve, Tip Normal, Ring Normal)
- Rigid nickel plated die-cast frame, featuring considerable frame strength eliminating physical distortion when plug is inserted
- Nickel-silver spring contacts, palladium plated switch contacts
- Tinned tags for easy soldering
Long frame B-Gauge Patch Panels
LF 48 B-Gauge Patch bays
- 48 way Long frame B-Gauge patch bay
- Accepts both European BPO 316 and US MIL-P-642/2 style phono plugs
- 2 rows of 24 LF501 jack connectors
- Jack designed from rigid nickel-plated die-cast aluminum with nickel-silver spring contacts
- Available in 4 colors: black, silver, red or blue
- Reliable support for connecting looms by steel lacing bar
Dimensional Drawing
LFJ 501 B-Gauge Jack Socket
- 5-point B-Gauge jack socket
- Nickel-silver spring contacts
- Palladium plated switch contacts
- Durable die-cast body with bright nickel plated nose
- Termination solder lugs
Technical Data
Specifications| | NPPA
Series| NPP-TB
Series| NYS
Series| MA 96 and
XPM 96| LF 48
Series
---|---|---|---|---|---|---
| | | | | |
E l e c t r i c a l| | | | | |
| | | | | |
Contact resistance:| | < 20 mW| < 10 mW| < 10 mW| < 24 mW| < 20 mW
Switch contact resistance:| | < 25 mW| < 15 mW| < 10 mW| < 26 mW| < 15 mW
Insulation resistance:| > 1 GW @ 500 V dc| ⚫| ⚫| ⚫| ⚫| ⚫
Dielectric strength:| > 500 V ac| ⚫| ⚫| ⚫| ⚫| ⚫
| > 1000 V dc| ⚫| ⚫| ⚫| –| – Frequency range:| DC to > 50 MHz| ⚫| ⚫| ⚫| ⚫| ⚫ Channel separation:| > 100 dB @ 10 kHz| ⚫| ⚫| ⚫| ⚫| ⚫ | 600 W terminated| | | | | | > 40 dB @ 6 MHz| ⚫| ⚫| ⚫| ⚫| ⚫ | 110 W terminated| | | | | AES / EBU Signals (digital) suitable:| ⚫| ⚫| ⚫| ⚫| ⚫ Handles Phantom Power:| | ⚫| ⚫| ⚫| ⚫| ⚫ | | | | | | **M** **e** **c** **h** **a** **n** **i** **c** **a** **l**| | | | | | | | | | | | Life time:| > 20
000 cycles| –| –| –| ⚫| ⚫
| > 10000 cycles| –| –| ⚫| –| – | > 5
000 cycles| ⚫| ⚫| –| –| –
Insertion force:| < 25 N| –| –| –| ⚫| ⚫
| < 20 N| –| –| ⚫| –| –
| < 10 N| ⚫| ⚫| –| –| –
Withdrawal force:| > 10 N| ⚫| ⚫| ⚫| ⚫| ⚫
| > 8 N| ⚫| ⚫| –| –| –
Dimensions:| 482 x 44 mm (19″ x 1U)| ⚫| ⚫| ⚫| ⚫| ⚫
Depth:| | 178 mm (7″)| 140 mm (5.5″)| 64 mm (2.52″)| 110 mm (4.33″)| 115 mm
(4.53″)
Dimension Patch Box:| 168 x 77 x 77 mm (6.0 x 3| x 3″)| | | |
Temperature range:| – 30 °C to + 80 °C| ⚫| ⚫| ⚫| ⚫| ⚫
Mating plug:| | 4.4 mm (0.173″)| B-Gauge 1/4″ plug| A-Gauge 1/4″ plug| 4.4 mm
(0.173″)| Longframe
| | Bantam plug| | acc. EIA RS-453| Bantam plug| B-Gauge plug
| according| MIL-P-642/13| BPO316/MIL-P-642/2| TEC60603-11| MIL-P-642/13|
BPO316/MIL-P-642/2
Grounding wiring| flat tab for 3/16″| –| –| ⚫| –| –
| FASTON® (4.8 x 0.8 mm)| | | | |
| | | | | |
M a t e r i a l| | | | | |
| | | | | |
Housing:| | Steel| Steel| Steel| anodised Al| anodised Al
Front panel:| | anodised Al| Pocan B 3225| Steel| anodised Al| anodised Al
Lacing bar:| | Brass| Steel| N / A| coated steel| coated steel
Jack housing:| | PA 66 blend| PA 6.6 30% GR| ABS| diecast alloy| diecast Al
Jack contacts:| | CuSn6| CuSn6| CuSn6| Ni-Silver| Ni-Silver
| | Tribor® plated| Au plated| tin plated| (CuNi18Zn20)| (CuNi18Zn20)
Switch contacts:| | Au plated| Au plated| Bronze, tin plated| Palladium
plated| Palladium plated
Grounding clip:| | –| –| CuSn6, SnCu plated| –| –
Operating Accessories
Labeling software
Patch label is a program to Label Patch Panel designation strips.
Free download of Patch Label Program (ZIP – 347 KB) on the Web
“www.neutrik.com” section “Patch Panels”.
Ordering Information
Part Number / Description
NPP A Series | Configuration* | Wiring | Grounding | |
---|---|---|---|---|
NPPA-TT-PT** | 2 x 48 jacks | half normalled bottom | 288 push terminals |
individual
NPPA-TT-PT-FN| 2 x 48 jacks| full normalled| 288 push terminals| individual
NPPA-TT-PT-HNT| 2 x 48 jacks| half normalled top row| 288 push terminals|
individual
NPPA-TT-PT-I| 2 x 48 jacks| isolated| 288 push terminals| individual
NPPA-TT-PT-P| 2 x 48 jacks| parallel| 288 push terminals| individual
NPPA-TT-S| 2 x 48 jacks| half normalled bottom| 288 solder terminals|
individual
NPPA-TT-S-FN| 2 x 48 jacks| full normalled| 288 solder terminals| individual
NPPA-TT-S-HNT| 2 x 48 jacks| half normalled top row| 288 solder terminals|
individual
NPPA-TT-S-I| 2 x 48 jacks| isolated| 288 solder terminals| individual
NPPA-TT-S-P**| 2 x 48 jacks| parallel| 288 solder terminals| individual
NPPA-TT-PT-PH| 2 x 48 jacks| half normalled bottom| 288 Phoenix push
terminals| individual
NPPA-TT-SD50| 2 x 48 jacks| half normalled bottom| 4 x 50 pole D-SUB| groups
of 12 channels
NPPA-TT-SD25| 2 x 48 jacks| half normalled bottom| 12 x 25 pole D-SUB| groups
of 12 channels
NPPA-TT-E56| 2 x 48 jacks| half normalled bottom| 6 x 56 pole ELCO male
connectors| individual
NPPA-TT-E90| 2 x 48 jacks| half normalled bottom| 4 x 90 pole ELCO male
connectors| individual
NPPA-TT-IDC| 2 x 48 jacks| programmable by jumpers| 288 IDC terminals (KRONE-
Type)| individual
-
: fully loaded jack pairs only, to built patch panels with mixed configuration use pre-config jacktars
: in case of need added norm Alling bars can be used to reconfigure up to 4 jacktars
Pre- configured Jack- Pairs**NJ3TTA-4-HNB| blocks of 2 channels| half normalled bottom row| cover ident color: clear
NJ3TTA-4-HNT| blocks of 2 channels| half normalled top row| cover ident color: yellow
NJ3TTA-4-FN| blocks of 2 channels| full normalled| cover ident color: green
NJ3TTA-4-P| blocks of 2 channels| parallel| cover ident color: red
NJ3TTA-4-I| blocks of 2 channels| isolated| cover ident color: orange
| | |
Accessories| | |
NPPA-S| Strain Relief bar| |
NKTT*| Patch cords with NP3TT| -1 plugs. Available in black,| blue, green, red and yellow. Length: 30, 40, 60, 90, 120 cm
NPP- TB| Series| Configuration Wiring
---|---|---
NPP-TB| 2 x 24 TB (BP0316/MIL-P-642/2) jacks| programmable for all commonly used configurations push terminals- NPP-TB-HN
- 2 x 24 TB (BP0316/MIL-P-642/2) jacks
- half Nonmilled Bottom Row
- solder tags
- NPP-TB-HN
Definitions, Abbreviations & Useful Information
Part Number Guide
NEUTRIK, crystalCON®, etherCON®, maxCON®, miniCON®, nanoCON®, neutriCON®, opticalCON®, powerCON®, powerCON® TRUE1, Profi®, rearTWIST®, silentPLUG®, speakON®, TOP®, DiWA®, XIRIUM®, are registered trademarks of Neutrik AG.
Neutrik ® Product Line
The premium brand of the Neutrik Group
LIECHTENSTEIN (HEADQUARTERS)
Neutrik AG, Im alten Riet 143, 9494 Schaan
T +423 237 24 24, F +423 232 53 93,
neutrik@neutrikgroup.com
GERMANY / NETHERLANDS / DENMARK / AUSTRIA
Neutrik Vertriebs GmbH, Felix-Wankel-Straße 1, 85221 Dachau, Germany
T +49 8131 28 08 90,
neutrik@neutrikgroup.de
GREAT BRITAIN
Neutrik (UK) Ltd., Westridge Business Park, Cothey Way
Ryde, Isle of Wight PO33 1 QT
T +44 1983 811 441,
sales@neutrikgroup.co.uk
FRANCE
Neutrik France SARL, 52 rue d’aguesseau, 1er etage, 92100 Boulogne-Billancourt
T +33 1 41 31 67 50, info@neutrikgroup.fr
USA
NeutrikAmericas, 4115 Taggart Creek Road, Charlotte, North Carolina, 28208
T +1 704 972 3050, info@neutrikusa.com
JAPAN
Neutrik Limited, Yusen-Higashinihonbashi-Ekimae Bldg., 3-7-19
Higashinihonbashi, Chuo-ku, Tokyo 103
T +81 3 3663 47 33, mail@neutrik.co.jp
HONG KONG
Neutrik Hong Kong Ltd., Suite 18, 7th Floor Shatin Galleria
Fotan, Shatin
T +852 2687 6055, sales@neutrik.com.hk
CHINA
Ningbo Neutrik Trading Co., Ltd., Shiqi Street, Yinxian Road West
Fengjia Village, Hai Shu Area, Ningbo, Zhejang, 315153
T +86 574 88250833, sales@neutrik.com.cn
ASSOCIATED COMPANIES
Contrik AG
Steinackerstrasse 35, 8902 Urdorf, Switzerland
T +41 44 736 50 10, contrik@contrik.ch
H. Adam GmbH
Felix-Wankel-Straße 1, 85221 Dachau, Germany
T +49 08131 28 08-0, anfrage@adam-gmbh.de
CONNEX GmbH
Elbertraße 12, 26135 Oldenburg, Germany
T +49 441 380398-0, info@connex.de