NEUTRIK NE8MX6-T CAT6A Cable Connector Instruction Manual
- October 30, 2023
- NEUTRIK
Table of Contents
- NEUTRIK NE8MX6-T CAT6A Cable Connector Instruction Manual
- Tools: l HX-CAT6A or pliers wrench
- A Slide the boot (1.) and the chuck (2.) onto the cable
- A. S / FTP
- B. U / FTP
- C. SF / UTP
- etherCON CAT6A – ASSEMBLY INSTRUCTION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NEUTRIK NE8MX6-T CAT6A Cable Connector Instruction Manual
Tools: l HX-CAT6A or pliers wrench
- Wire cutter
- Cable pulling lubricant
A Slide the boot (1.) and the chuck (2.) onto the cable
B Prepare the cable as shown and strip the jacket at a length of 40 mm
A. S / FTP
Cut off braided shield to approx 10 mm and fold the shield backwards.
B. U / FTP
Remove the foil of the paired wires and bend back the drain wire for easier handling during assembly. Drain wire to be used for grounding.
C. SF / UTP
Cut off braided shield to approx 10 mm and fold the shield backwards. Cut and remove the foil screen
Remove the pair screening (if existing) to max. 6 mm.
Presort and untwist the pairs as shown.
C Insert the wires into the designated position of the wire management as per below wiring scheme, either T568A or T568B
etherCON CAT6A – ASSEMBLY INSTRUCTION
D Use HX-CAT6A or pliers wrench to press the wire management together.
Attention:
Distance between the cable jacket and the wire management shall not exceed 15
– 17 mm.
E Cut all wires with a wire cutter. Allow wires to protrude max. 0.5 mm.
Remove the assembly guidance.
Position the ground-shells over the wires as shownAttention:
Align the coding nibs of the ground shells to the grooves in between the wire
pairs in the wire management
F Put the cable-shield over the ground shell and distribute the shield wires circumferentially
B Put the drain wire over the ground shell and wrap the drain wire
circumferentially
G Slide the chuck over the cable-shield / drain wire and the ground shell
towards the end-position.
Attention: Align the slots of the chuck to the ribs of the ground shell.
H Slide the pre assembled cable (step G) into the housing
Slide the gasket onto the chuck.
Finish the installation by turning the bushing onto the connector.