NEUTRIK NE8MX6-T CAT6A Cable Connector Instruction Manual
- October 30, 2023
- NEUTRIK
Table of Contents
- NEUTRIK NE8MX6-T CAT6A Cable Connector Instruction Manual
- Tools: l HX-CAT6A or pliers wrench
- A Slide the boot (1.) and the chuck (2.) onto the cable
- A. S / FTP
- B. U / FTP
- C. SF / UTP
- etherCON CAT6A – ASSEMBLY INSTRUCTION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NEUTRIK NE8MX6-T CAT6A Cable Connector Instruction Manual
Tools: l HX-CAT6A or pliers wrench
- Wire cutter
- Cable pulling lubricant
A Slide the boot (1.) and the chuck (2.) onto the cable
B Prepare the cable as shown and strip the jacket at a length of 40 mm
A. S / FTP
Cut off braided shield to approx 10 mm and fold the shield backwards.
B. U / FTP
Remove the foil of the paired wires and bend back the drain wire for easier handling during assembly. Drain wire to be used for grounding.
C. SF / UTP
Cut off braided shield to approx 10 mm and fold the shield backwards. Cut and remove the foil screen
Remove the pair screening (if existing) to max. 6 mm.
Presort and untwist the pairs as shown.
C Insert the wires into the designated position of the wire management as per below wiring scheme, either T568A or T568B
etherCON CAT6A – ASSEMBLY INSTRUCTION
D Use HX-CAT6A or pliers wrench to press the wire management together.
Attention:
Distance between the cable jacket and the wire management shall not exceed 15
– 17 mm.
E Cut all wires with a wire cutter. Allow wires to protrude max. 0.5 mm.
Remove the assembly guidance.
Position the ground-shells over the wires as shownAttention:
Align the coding nibs of the ground shells to the grooves in between the wire
pairs in the wire management
F Put the cable-shield over the ground shell and distribute the shield wires circumferentially
B Put the drain wire over the ground shell and wrap the drain wire
circumferentially
G Slide the chuck over the cable-shield / drain wire and the ground shell
towards the end-position.
Attention: Align the slots of the chuck to the ribs of the ground shell.
H Slide the pre assembled cable (step G) into the housing
Slide the gasket onto the chuck.
Finish the installation by turning the bushing onto the connector.
Read More About This Manual & Download PDF: