godrej GBR 100 DC Blood Refrigerator Instruction Manual

June 17, 2024
Godrej

godrej-logo

godrej GBR 100 DC Blood Refrigerator

Product Information

The product is a multifunctional device that offers a wide range of features and capabilities. It is designed to provide convenience and efficiency in various tasks. Whether you need to perform basic functions or more advanced operations, this product is equipped to meet your needs.

Specifications

  • Model: [Model Number]
  • Dimensions: [Dimensions]
  • Weight: [Weight]
  • Power Supply: [Power Supply]
  • Display: [Display Specifications]
  • Connectivity: [Connectivity Options]

Features
The product comes with a variety of features that enhance its functionality:

  • Feature 1: [Description of Feature 1]
  • Feature 2: [Description of Feature 2]
  • Feature 3: [Description of Feature 3]
  • Feature 4: [Description of Feature 4]

Included Accessories
The product package includes the following accessories:

  • Accessory 1: [Description of Accessory 1]
  • Accessory 2: [Description of Accessory 2]
  • Accessory 3: [Description of Accessory 3]

Product Usage Instructions

  1. Step 1: Unboxing
    Start by opening the product package carefully. Remove all packaging materials and verify that all the included accessories are present.

  2. Step 2: Powering On
    Connect the product to a power source using the provided power supply. Press the power button located [location of power button] to turn on the device.

  3. Step 3: Initial Setup
    Follow the on-screen instructions to complete the initial setup process. This may include selecting language preferences, connecting to a Wi-Fi network, and signing in with your user account.

Step 4: Basic Functions
The product offers various basic functions that can be accessed through the intuitive user interface. These functions may include:

  • Function 1: [Description of Function 1]
  • Function 2: [Description of Function 2]
  • Function 3: [Description of Function 3]

Step 5: Advanced Operations
If you wish to explore more advanced operations, refer to the product’s user manual for detailed instructions on specific features and settings.

Step 6: Maintenance and Care
To ensure optimal performance and longevity of the product, follow these maintenance guidelines:

  • Guideline 1: [Maintenance Guideline 1]
  • Guideline 2: [Maintenance Guideline 2]
  • Guideline 3: [Maintenance Guideline 3]

Frequently Asked Questions (FAQ)

  • Q: How do I update the software?
    A: To update the software, go to the Settings menu and look for the “Software Update” option. Follow the on-screen instructions to download and install the latest software version.

  • Q: Can I connect the product to my mobile device?
    A: Yes, the product supports connectivity with mobile devices. Install the companion app on your mobile device and follow the instructions for pairing and connecting.

  • Q: How do I clean the product?
    A: Use a soft, lint-free cloth slightly dampened with water or a mild cleaning solution to clean the exterior surfaces of the product. Avoid using abrasive materials or harsh chemicals that may damage the device.

Installer’s instruction manual

  • Keep these instructions close to the refrigerator.
  • “For water quantity, refer page 31.

GBR 100 DC – Solar Direct Drive Blood Bank Refrigerator
MODEL NUMBER: GBR 100 DC
Sure Chill9 is a patented technology, licensed by The Sure Chill Company
——————————-
GBR 100 DC – Solar Direct Drive Blood Bank Refrigerator www.godrejappliances.com/medical

SAFETY INSTRUCTIONS

  • Do not climb on appliances
  • Be careful not to trap fingers
  • Do not keep flammable substances near appliance
  • Servicing must be carried out by qualified maintenance technician
  • Caution! Appliance contains refrigerant and electrolyte capacitor
  • Warning! Appliance is solar powered all parts are live in daylight

TOOLS REQUIRED

  • Screwdrivers
  • Spanners
  • Hammer
  • Knife
  • Multimeter

HANDLING INSTRUCTIONS

  • Keep appliance vertical- do not tilt more than 30°
  • Keep door closed when moving appliance
  • Comply with manual handling regulations when moving appliance
  • Empty the appliance of liquid before moving

MOUNTING FRAME COMPONENTS

  • Module end and middle clamps
  • Mounting rail
  • Foot
  • Security bolts, washers and nuts

INSTALLATION ADVICE

  • Take precautions when working at height
  • Keep solar modules completely covered during installation process
  • Use appropriate fixings to attach array to surface
  • Not all mounting frame components may be required for installation

SOLAR PANEL INSTALLATION DETAILS

godrej-GBR-100-DC-Blood-Refrigerator-01 \(23\) SOLAR ARRAY INSTALLATION MANUAUL

Important Safety Instruction

  • Take precautions when working at height
  • Make sure that the mounting surface is strong enough to carry your weight
  • Use fall restraint system when working on roofs
  • PV modules generate high voltages in sunlight – cover all modules until all wires are connected

Important Note
Use mounting system supplied to tilt solar modules to 15° or the locations latitude, whichever is greater

SOLAR ARRAY INSTALLATION MANUAUL
Attach feet to the surface so that they are correctly spaced for required angle

Angle x(mm) 2x(mm)
15· 1340 2680
20· 1285.5 2571
25· 1214 2428
30· 1124 2248
35· 1012 2024

SOLAR ARRAY INSTALLATION MANUAUL

  • Solar modules can be installed on a flat or sloping surface facing the equator
  • Install solar modules in an unshaded location
  • Only put fixing in to solid structure
  • Use proper fixings to attach array to surface
  • Remove all the cardboard packing before installation
  • Ensure all electrical connections are firm with correct polarity

LIST OF ITEMS

Solar kit item listgodrej-GBR-100-DC-Blood-
Refrigerator-65 godrej-GBR-100-DC-Blood-
Refrigerator-66 godrej-GBR-100-DC-Blood-
Refrigerator-67

INSTALLATION PROCEDURE

  1. Unpack the solar panel boxgodrej-GBR-100-DC-Blood-Refrigerator-01 \(29\)
  2. Insert foot in the lower end of the rail
  3. Fix the foot with M8X70 boltgodrej-GBR-100-DC-Blood-Refrigerator-01 \(30\)
  4. Insert and fix foot in smaller leg
  5. Insert and fix another foot in longer leggodrej-GBR-100-DC-Blood-Refrigerator-01 \(31\)
  6. Fix all the feet
  7. Fix and tighten all the feet and erect the framegodrej-GBR-100-DC-Blood-Refrigerator-01 \(32\)
  8. Insert the angle brace as shown in figure
  9. Similarly fix all the feet on rail on the other sidegodrej-GBR-100-DC-Blood-Refrigerator-01 \(33\)
  10. After fixing all the feet in the mounting rails, attach feet of the frame to the supporting surface using the appropriate fixing – expansion bolts for concrete, coach screws for timber joists, J-bolt for steel sections, etc.
  11. Insert and slide the solar panel mounting end clamps on both sides with proper directiongodrej-GBR-100-DC-Blood-Refrigerator-01 \(35\)
  12. Rest the solar panel on the lower part of the frame with the help of mounting clamps and tighten them with theft deterrent fasteners using theft deterrent key as shown in above figuregodrej-GBR-100-DC-Blood-Refrigerator-01 \(36\)
  13. Take solar panel mounting mid clamp and slide spring nut inside the slotted rail on the both sidesgodrej-GBR-100-DC-Blood-Refrigerator-01 \(37\)
  14. Fix the middle solar panel mounting clamp on both sides and rest the other solar pane on the framegodrej-GBR-100-DC-Blood-Refrigerator-01 \(38\)
  15. Fix and tighten the bracket with the help of theft deterrent fastener after making sure both the panels are clamped and slide the top clamp on both sidesgodrej-GBR-100-DC-Blood-Refrigerator-01 \(39\)
  16. Clamp the solar panel with clamps and tighten them with theft deterrent boltsgodrej-GBR-100-DC-Blood-Refrigerator-01 \(40\)
  17. Connect the connectors from the solar panel to the branch connector, ensure proper polaritygodrej-GBR-100-DC-Blood-Refrigerator-01 \(41\)
  18. Fix/ Clamp earth cable (20Mtrs) in the lay in lug fixed to the vent opening
  19. Similarly fix lay in lug to the solar array angle and clamp the other (5mtr) earth cablegodrej-GBR-100-DC-Blood-Refrigerator-01 \(43\)

EARTHING THE ARRAY

  • Bond the solar modules and mounting frame togethergodrej-GBR-100-DC-Blood-Refrigerator-01 \(45\)
  • On the following pages we indicate how we would advise you to install an earthing rod.
  • However we appreciate that existing methods in your locality might serve very well and you might well choose to follow those.

OPTIONS

  • If the ground in the locality is solid, then using equipment provided, we suggest using a charcoal and salt pit
  • Excavate to a depth of about 1.35m (top of your chest), with a diameter of at least 1mgodrej-GBR-100-DC-Blood-Refrigerator-01 \(46\)
  • Dampen the bottom of the pit. Put a layer of charcoal with a layer of salt on top such that the remaining depth is about 1.2m (the earthing rod should just stick out above ground level); then a further good soaking of water.godrej-GBR-100-DC-Blood-Refrigerator-01 \(47\) godrej-GBR-100-DC-Blood-Refrigerator-01 \(48\)
  • If you so wish, you can make this more effective by adding the following features (although you will have to source these components as we don’t supply them)godrej-GBR-100-DC-Blood-Refrigerator-01 \(49\)
  • After the last layer of salt has been laid, as the remaining depth is filled with earth, insert a pipe and connecting funnel or bucket. The funnel or bucket should be mounted such that it can be covered and not get damaged. By using this funnel and pipe, water can be delivered to the top layers of charcoal and salt, which will then fall naturally through the layers.godrej-GBR-100-DC-Blood-Refrigerator-01 \(50\)
  • However if the ground conditions are regularly damp but not overly wet, you could use the following method if you so choosegodrej-GBR-100-DC-Blood-Refrigerator-01 \(51\)

CONNECTING SOLAR MODULES

  • Ensure the solar modules are completely covered before touching solar cables!
  • Remove cover from solar modules and test the voltage with a multimeter

POSITIONING INSTRUCTIONS

  • Position appliance to allow free air movement all a round
  • Position appliance away from direct sunlight
  • Allow for access to remove appliance lid
  • Ensure unit is level before filling
  • Check that support bridge and condensation baffle are correctly positioned
  • Note: The baffle is designed to be loosegodrej-GBR-100-DC-Blood-Refrigerator-01 \(58\)

FILLING INSTRUCTIONS

  • Remove ventilated lid and screw cap and fill with clean drinking water 230mm from top of pipegodrej-GBR-100-DC-Blood-Refrigerator-01 \(59\)
  • Observe safe working practices when filling the appliance
  • Do not overfill the unitgodrej-GBR-100-DC-Blood-Refrigerator-01 \(61\)
  • Replace screw cap and securely attach ventilated lid before starting the compressor

Fill the Device with 135L clean drinking water. Good examples of clean drinking water would be municipal water ( mains water supply), Reverse Osmosis (RO) water, distilled water or clean, bottled drinking water. The water should not be dirty nor contaminated. A mild dose of chlorine, consistent with drinking water quality standards, is helpful in disinfecting both the water and the container.

For a full description refer to the latest World Health Organisation publication on the subject:

CONNECTING APPLIANCE

  • Connect the appliance to the power isolator using cable and fixings providedgodrej-GBR-100-DC-Blood-Refrigerator-01 \(63\)
  • Please double check all the system’s visible connections done, in both the factory and your location
  • Allow 24 hours after transportation before starting the compressor
  • Confirm appliance is operational by checking temperatures are displayed on the solar display* and check door is securely closed
  • Appliance cools slowly and will reach safe storage temperature within 6- 8 days after commissioning.

CUSTOMER SUPPORT

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals