NI CVS-1450 Series Compact Vision System
User Guide
Vision Builder for Automated Inspection
Connect the Hardware
Caution Before installing NI CVS-1450 Series hardware, refer to the
safety information in the NI CVS-1450 Series User Manual.
Connect the Camera and Monitor to the NI CVS-1450 Device
A. Connect the VGA cable from the monitor to the VGA port on the NI CVS-1450
device.
B. Plug the IEEE 1394 cable into one of the IEEE 1394 ports on the NI CVS-1450
device. Plug the other end of the cable into the IEEE 1394 port of the camera.
C. Plug in and power on the monitor.
Wire Power to the NI CVS-1450 Device
This section explains how to connect the power supply (part number 778794-01)
o the NI CVS-1450 device. For instructions on how to connect a separate main
supply, refer to the NI CVS-1450 Series User Manual.
Caution Do not connect the NI CVS-1450 device to a power source other than 24
VDC +10%. Refer to the NI CVS-1450 Series User Manual for information about
power requirements.D. Plug
the 4-position connector from the power supply into the power receptacle on
the NI CVS-1450 device.
E. Plug the power cord into the power supply.
F. Plug the power cord into an outlet.
Once connected, the NI CVS-1450 device runs a startup program that acquires
images and displays them on the monitor. These images verify that the hardware
is properly connected.
Connect the NI CVS-1450 Device to the Development Computer
Verify that the development computer is connected to the network and powered
on. G. Using a standard CAT 5 Ethernet cable (part number 189174), connect
from the network port to the Ethernet port on the NI CVS-1450 device.
H. Using a standard CAT 5 Ethernet cable, connect from the network port to the
Ethernet port on the development computer.
Note If you are not connecting through a network, use a crossover cable (part
number 187375) to connect the NI CVS-1450 device to the development computer.
Install the Software
Note You must install Vision Builder for Automated Inspection (Vision Builder
AI) before installing the NI-IMAQ for IEEE 1394 Cameras driver software.
Install Vision Builder AI and NI-IMAQ for IEEE 1394 Cameras
A. Insert the Vision Builder AI CD. When the installation splash screen
appears, click Install Vision Builder for Automated Inspection and follow the
setup instructions. Install NI-IMAQ for IEEE 1394 Cameras
B. When prompted, insert the NI Vision Acquisition Software CD. C. In the
Features tree, select NI-IMAQ for IEEE 1394 Cameras and NI-IMAQ for IEEE 1394
Hardware Support.D. Click Next.
E. Follow the installer prompts to complete the installation.
Configure the NI CVS-1450 Device
Obtain an IP Address
A. Launch Vision Builder AI.
B. Expand the Execution Target pull-down listbox and click Select Network
Target.C. In the Select
Remote Target window, click 192.168.10.12 to highlight the row.
This IP address is assigned to all unconfigured NI CVS-1450 devices.
Tip To uniquely identify unconfigured NI CVS-1450 devices, connect and
configure one NI CVS-1450 device at a time.
D. Click CCoonnffiigguurree to launch the Remote Target Configuration Wizard.
E. In the Identification window, enter a name for the NI CVS-1450 device in
the NNaammee field and a description of the NI CVS-1450 device in he
DDeessccrriippttiioonn field.
Note Device names are limited to 15 characters with no spaces or special
characters. The first and last letters must be alphanumeric. F. Click Next.
G. If the network is configured to issue IP addresses using DHCP, select
Obtain IP Address from DHCP Server. Otherwise, set the IP address manually by
selecting Edit IP Settings, Suggest Values, and OK.
H. Click Next.![NATIONAL INSTRUMENTS NI CVS-1450 Series Compact Vision System
- Click Next](https://manuals.plus/wp-content/uploads/2024/01/NATIONAL-
INSTRUMENTS-NI-CVS-1450-Series-Compact-Vision-System-Click-Next.jpg)
Download Software to the NI CVS-1450 Device
I. Select the Update Target Software checkbox.
J. Click OK to begin configuring the IP address and downloading software onto the NI CVS-1450 device. This initial installation process takes several minutes.
Acquire an Image
A. Launch Vision Builder AI.
B. Expand the Execution Target pull-down listbox, and click Select Network
Target. C. Select the NI CVS-1450 device you configured, and click OK.
D. On the Vision Builder AI Welcome screen, click Configure Inspection. E.
From the Acquire Images palette, click Acquire Image (IEEE 1394). F. Click the
Snap button to acquire a single image, or click the Grab button to acquire
continuous images.
Once you have configured your acquisition, click OK to add the step. You can
now add inspection steps as described in the NI Vision Builder for Automated
Inspection: Configuration Help.
QUICK START GUIDE
NI CVS-1450 Series Compact Vision System
This document describes how to set up and acquire an image using the NI
CVS-1450 Series compact vision system with NI Vision Builder for Automated
Inspection or the LabVIEW Real-Time Module and the NI Vision Development
Module. Use these instructions to verify that hardware and software are
properly installed, to configure an IP address for the CVS-1450 device, and to
acquire an image.
Note These instructions are intended for basic installation and configuration.
Refer to the NI CVS-1450 Series User Manual and the application software
documentation for detailed installation and configuration instructions.
Refer to the blue side of this document if you are using
Vision Builder for Automated Inspection
Refer to the yellow side of this document if you are using the LabVIEW Real-
Time Module with the NI Vision Development Module
373609B-01 Mar06
National Instruments, NI, ni.com, and LabVIEW are trademarks of National
Instruments Corporation.
Refer to the Terms of Use section on ni.com/legal for more information about
National Instruments trademarks. Other product and company names mentioned
herein are trademarks or trade names of their respective companies. For
patents covering National Instruments products, refer to the appropriate
location: Help»Patents in your software, the patents.txt file on your CD, or
ni.com/patents.
© 2003–2006 National Instruments Corporation. All rights reserved.
QUICK START GUIDE NI CVS-1450 Series Compact Vision System
LabVIEW Real-Time Module with the NI Vision Development Module
Connect the Hardware
Caution Before installing NI CVS-1450 Series hardware, refer to the safety
information in the NI CVS-1450 Series User Manual.
Connect the Camera and Monitor to the NI CVS-1450 Device
A. Connect the VGA Cable from the monitor to the VGA port on the NI CVS-1450
device.
B. Plug the IEEE 1394 cable into one of the IEEE 1394 ports on the NI CVS-1450
device. Plug the other end of the cable into the IEEE 1394 port of the camera.
C. Plug in and power on the monitor. Wire Power to the NI CVS-1450 Device
This section explains how to connect the power supply (part number 778794-01)
to the NI CVS-1450 device. For instructions on how to connect a separate main
supply, refer to the NI CVS-1450 Series User Manual.
Caution Do not connect the NI CVS-1450 device to a power source other
than 24 VDC +10%. Refer to the NI CVS-1450 Series User Manual for information
about power requirements.D. Plug the 4-position connector from the power supply into the
power receptacle on the NI CVS-1450 device.
E. Plug the power cord into the power supply.
F. Plug the power cord into an outlet.
Once connected, the NI CVS-1450 device runs a startup program that acquires
images and displays them on the monitor. These images verify that the hardware
is properly connected.
Connect the NI CVS-1450 Device to the Development Computer
Verify that the development computer is connected to the network and powered
on.G. Using a standard CAT 5 Ethernet cable (part number 189174),
connect from the network port to the Ethernet port on the NI CVS-1450 device.
H. Using a standard CAT 5 Ethernet cable, connect from the network port to the
Ethernet port on the development computer.
Note If you are not connecting through a network, use a crossover cable
(part number 187375) to connect the NI CVS-1450 device to the development
computer.
Install the Software
Note You must install LabVIEW, the LabVIEW Real-Time Module, and the NI
Vision Development Module software before installing the NI-IMAQ for IEEE 1394
Cameras driver software.
Install LabVIEW and the LabVIEW Real-Time Module
A. Insert the LabVIEW CD. When the installation screen appears, click Install
LabVIEW and follow the setup instructions. B. Insert the LabVIEW Real-Time Module CD.
When the installation screen appears, click Install LabVIEW Real-Time Module
and follow the setup instructions.Install the NI Vision Development Module and
NI-IMAQ for IEEE 1394 Cameras
C. Insert the NI Vision Development Module CD. When the installation screen
appears, click Install NI Vision Development Module and follow the setup
instructions.D. When
prompted, insert the NI Vision Acquisition Software CD. E. In the Features
tree, select NI-IMAQ for IEEE 1394 Cameras and NI-IMAQ for IEEE 1394 Hardware
Support. F.
Click Next.
G. Follow the installer prompts to complete the installation.
Configure the NI CVS-1450 Device
Obtain an IP Address A. Launch Measurement & Automation Explorer (MAX) and expand the
Remote Systems branch of the configuration tree.
B. Click 192.168.10.12 to display the Network Settings window. This IP address
is assigned to all unconfigured NI CVS-1450 devices.
Tip To uniquely identify unconfigured NI CVS-1450 devices, connect and
configure one NI CVS-1450 device at a time.
C. In the Network Settings window, type a name for the NI CVS-1450 device in
the NNaammee field and a description of the NI CVS-1450 device in the
CCoommmmeenntt field
Note Device names are limited to 15 characters with no spaces or special
characters.
The first and last letters must be alphanumeric devices.
D. If the network is configured to issue IP addresses using DHCP, select
Obtain IP address from DHCP server. Otherwise, set the IP address manually by
selecting Edit the IP settings, Suggest Values, and OK.
E. Click Apply. When prompted, click Yes to restart the NI CVS-1450 device.
This initial installation process takes several minutes.
While the NI CVS-1450 device is restarting, a red X appears next to the device
name to indicate that the NI CVS-1450 device is disconnected.
The MAX status bar also indicates the connection status of the NI CVS-1450
device.
Download Software to the NI CVS-1450 Device
F. In the MAX configuration tree, expand the device folder by clicking the
plus sign next to the device name.
G. Click the Software branch.
H. Click the Add//Remove Software button.
I. Select the software to install on the NI CVS-1450 device.J.
Click Next.
The NI CVS-1450 device will automatically restart. This process takes several
seconds.
Acquire an Image
You can acquire an image using MAX or the LabVIEW Real-Time Module.
Acquire an Image using MAX
A. Launch MAX.
B. In the MAX configuration tree,
expand the device folder.
C. Expand DDeevviicceess aanndd Interfacces.
D. Expand NI–IMAQ IEEE 11394 Devices
E. Select a camera.
F. Click the Snap button to acquire
a single image, or click the Grab button to acquire continuous
images.
Acquire an Image using the LabVIEW Real-Time Module
A. Launch LabVIEW, and select to create a new Real-Time Project.
B. Select Custom project for the Project type, enter a Project name, select
the Project folder where you want to store the project, and click5
Next.C. Select Add blank vi to target, and click Next.
D. Select the Networked option for Browse targets, and click Browse.
E. Select the Existing target or device option from Targets and Devices,
expand the Compact Vision System branch, select your device, and click OK. F.
Click Next.
G. Verify that the NI CVS-1450 device appears correctly in the LabVIEW Real-
Time Project, and click Finish.H. In the Project Explorer window, right-
click the name of your NI CVS-1450 device, and select Add File.
I. Navigate to Program Files\ National Instruments\ LabVIEW 8.0\examples\
IMAQ\IMAQ1394 examples.llb, and click Add File.
J. Click Grab.vi, and click Select.
K. Click the Run button to begin acquiring images.
Now that you are acquiring images in LabVIEW, you can use the NI Vision
Development Module and the installed NI CVS-1450 device drivers to process
images and to control inputs and outputs.