eurener 420 PV Module User Manual

June 16, 2024
eurener

eurener 420 PV Module User Manual
eurener 420 PV Module


N-type cell

Higher resistance to LID and LeTID.


TOP Con

Technology to increase cell efficiency.


Bifacial cell

Improved energy yield.


Easy to handle

Comfortable installation thanks to an optimized area size.


Better temperature
coefficient
Minimized thermal losses, improved efficiency.

Sustainable product
Sustainable product

High percentage of recyclable materials.

25 Years

Product Warranty
+5 years for Premium Partners

30 Years

Performance Warranty
Linear Warranty

88% performance at 30 years
Performance

Mechanical Specification

Solar cells| 108 (6 x 18), N-Type bifacial mono crystalline silicon cells
Front Glass| 2mm anti-reflective surface solar glass
Back Glass| 2mm solar glass
Frame| Black/silver anodized aluminium
Junction Box| IP68, 3 by-pass diodes
Connector| Original MC4-Evo 2
Cable| 1000 mm (±20%) length and4 mm² section
Dimension| 1724 x 1134 x 30 mm (±1%)
Area| 1,96 m²
Weight and packaging| 23,4 kg, 962 pcs-truck
Temperature Coeficients
Temperature coeficient of Isc ( a)| 0,045 %/°C
Temperature coeficient of Voc ( b)| -0,275 %/°C
Temperature coeficient of Pmax ( g)| -0,29 %/°C
Temperature range| -40 °C ~ +85 °C
Nominal operating cell temperature (NOCT)| 45 ± 2 °C

Dimension
Performance

Black – Standard| MEPV 420| MEPV 425| MEPV 430| MEPV 435
---|---|---|---|---
STC: 1000 W/m2, module temperature 25ºC, AM 1,5
Nominal power. Pmax| 420 Wp| 425 Wp| 430 Wp| 435 Wp
Module efficiency| 21,49 %| 21,75 %| 22,01 %| 22,26 %
Short-circuit current (Isc)| 14,08 A| 14,16 A| 14,26 A| 14,30 A
Open-circuit voltage (Voc)| 38,09 V| 38,28 V| 38,42 V| 38,70 V
Maximum power current (Imp)| 13,34 A| 13,42 A| 13,52 A| 13,56 A
Maximum power voltage (Vmp)| 31,49 V| 31,68 V| 31,82 V| 32,09 V
NOCT: 800 W/m2, ambient temperature 20ºC, AM 1,5
Nominal power. Pmax| 321,64 W| 325,38 W| 329,33 W| 333,12 W
Short-circuit current (Isc)| 11,34 A| 11,41 A| 11,47 A| 11,54 A
Open-circuit voltage (Voc)| 36,52 V| 36,70 V| 36,88 V| 37,06 V
Maximum power current (Imp)| 10,75 A| 10,81 A| 10,88 A| 10,94 A
Maximum power voltage (Vmp)| 29,92 V| 30,10 V| 30,27 V| 30,45 V
Electrical characterristics with 10% rear side power gain
Nominal power. Pmax| 462,00 W| 467,50 W| 473,00 W| 478,50 W
Short-circuit current (Isc)| 15,43 A| 15,52 A| 15,63 A| 15,67 A
Open-circuit voltage (Voc)| 38,09 V| 38,31 V| 38,49 V| 38,85 V
Maximum power current (Imp)| 14,63 A| 14,72 A| 14,82 A| 14,86 A
Maximum power voltage (Vmp)| 31,58 V| 31,76 V| 31,91 V| 32,21 V
Operating parameters
Maximum voltage| 1000 – 1500 V
Maximum series fuse rating. Ir| 25 A
Power output tolerance| 0 – +3%
Voc and Isc tolerance| ±3%
Fire rating| Class A (UL 790)
Protection class| Class II (IEC 61140)
Hail resistance| Ø 25mm at 23 m/s (IEC 61215)
Mechanical loads| Front load 5400 Pa, Back load 2400 Pa

NOTE: Read the instruction manual of this product and follow the indications STC. Values are valid for: 1000W/m2, AM 1,5 and cells temperature of 25ºC.
Measurement tolerance +/-3% (AAA Solar simulation -IEC 60.904-9-). All the information of this brochure may be amended without notice by Eurener.

Manufacturing a better world
Since 1997 our main purpose has been to supply quality and long-lasting photovoltaic modules that allow us and future generations, to continue generating clean energy to take care of our planet.

Symbols
Symbols
Symbols
Symbols

eurener.com
contact@eurenerworld.com
+34 960 045 515
Calle Colón, 1-23
46004, Valencia. Spain

eurener Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals