ULTRA MEPV 108 Cells Eurener PV Module User Manual

June 16, 2024
eurener

ULTRA MEPV 108 Cells Eurener PV Module

ULTRA-MEPV-108-Cells-Eurener-PV-Module-product.

Product Information

Specifications

  • Model: MEPV 108 – ULTRA 450-460Wp
  • Cell Type: N-type
  • Number of Cells: 108
  • Power Output: 450-460Wp
  • Resistance: Higher resistance to LID and LeTID
  • Technology: ABC (Back Contact) technology with 100% sunlight received
  • Aesthetic: Premium aesthetic with elegant design and cells free from frontal metallization
  • Rooftop Integration: Suitable for commercial and residential rooftop integration
  • Handling: Easy to handle
  • Installation: Comfortable installation thanks to an optimized area size
  • Temperature Coefficient: Better temperature coefficient with minimized thermal losses and improved efficiency
  • Warranty: 20 years product warranty, additional 5 years for Premium Partners
  • Performance Warranty: 30 years linear warranty with 88.85% performance at 30 years

Product Usage Instructions

Installation

To install the Eurener MEPV 108 ULTRA module, follow these steps:

  1. Select a suitable location on the rooftop for installation.
  2. Ensure the surface is clean and free from any debris.
  3. Securely mount the frame of the module using appropriate brackets or mounting systems.
  4. Connect the module’s junction box to the wiring system using the provided connectors.
  5. Make sure all connections are properly insulated and protected from environmental factors.

Maintenance

To ensure optimal performance and longevity of the module, perform regular maintenance:

  • Inspect the module for any physical damage or signs of wear.
  • Clean the surface of the module with a soft cloth or sponge and mild detergent solution.
  • Avoid using abrasive materials or strong chemicals that may damage the module’s surface.
  • Check the wiring connections and junction box for any loose or damaged components.
  • If any issues are detected, contact a qualified technician for repairs or replacements.

Safety Precautions

When working with the Eurener MEPV 108 ULTRA module, observe the following safety precautions:

  • Ensure the module is not exposed to live electrical currents during installation or maintenance.
  • Use appropriate personal protective equipment, such as gloves and safety glasses.
  • Avoid stepping directly on the module to prevent damage.
  • Do not attempt to disassemble or modify the module without proper knowledge and expertise.
  • Keep children and unauthorized personnel away from the installation area.

FAQ

1. What is the warranty period for the Eurener MEPV 108 ULTRA module?

The product comes with a 20-year warranty. Premium Partners receive an additional 5 years of warranty.

2. What is the power output of the module?

The power output of the Eurener MEPV 108 ULTRA module is 450-460Wp.

3. Can the module be installed on both residential and commercial rooftops?

Yes, the module is suitable for integration on both residential and commercial rooftops.

4. How should I clean the module?

Use a soft cloth or sponge with a mild detergent solution to clean the surface of the module. Avoid using abrasive materials or strong chemicals.

5. What should I do if I detect any issues with the module?

If you detect any issues with the module, such as physical damage or performance issues, contact a qualified technician for repairs or replacements.

Ultra

MEPV 108 cells — Eurener PV Module
› 450/460Wp

N-type cell

Higher resistance to LID and LeTID

ABC technology

Back contact technology with 100% sunlight received

Premium aesthetic Commercial and residential rooftop integration

Easy to handle

Comfortable installation thanks to an optimized area size

Better temperature coeficient

Minimized thermal losses, improved efficiency

Elegant design

Cells free from frontal metallization

Warranty

  • 20 Years
    Performance Warranty

  • 30 Years
    Linear Warranty

Eurener MEPV 108 — ULTRA 450-460Wp

Mechanical Specification

Solar cells

| 108 (6 x 18), N-Type monocrystalline silicon cells

Front Glass

| 3,2 mm thick tempered glass with high strength and ARC
Frame| Black anodized aluminium
Junction Box| IP68, 3 by-pass diodes
Connector| Original MC4-Evo 2

Cable

| 1000 mm (±20%) length and

4 mm² section

Dimension| 1722 x 1134 x 30 mm (±1%)
Area| 1,95 m²
Weight and packaging| 20,5 kg, 936 pcs-truck
Temperature Coeficients
Temperature coeficient of Isc ( a)| 0,05 %/°C
Temperature coeficient of Voc ( b)| -0,24 %/°C
Temperature coeficient of Pmax ( g)| -0,29 %/°C
Temperature range| -40 °C ~ +85 °C
Nominal operating cell temperature (NOCT)| 43 ± 2 °C

Black MEPV 450 MEPV 460

STC: 1000 W/m2, module temperature 25ºC, AM 1,5
Nominal power. Pmax| 450 Wp| 460 Wp
Module efficiency| 22,98 %| 23,63 %
Short-circuit current (Isc)| 13,74 A| 13,91 A
Open-circuit voltage (Voc)| 40,24 V| 40,40 V
Maximum power current (Imp)| 13,21 A| 13,47 A
Maximum power voltage (Vmp)| 34,10 V| 34,20 V
NOCT: 800 W/m2, ambient temperature 20ºC, AM 1,5
Nominal power. Pmax| 339 Wp| 347 Wp
Short-circuit current (Isc)| 11,16 A| 11,24 A
Open-circuit voltage (Voc)| 37,84 V| 38,00 V
Maximum power current (Imp)| 10,64 A| 10,76 A
Maximum power voltage (Vmp)| 31,94 V| 32,27 V
Operating parameters
Maximum voltage| 1500 V
Maximum series fuse rating. Ir| 25 A
Power output tolerance| 0 – +3%
Voc and Isc tolerance| ±3%
Fire rating| Class C (UL 790)
Safety class| Class II (IEC 61140)
Hail resistance| HW3/RG3
Mechanical loads| Front load 5400 Pa, Back load 2400 Pa

NOTE: Read the instruction manual of this product and follow the indications STC. Values are valid for: 1000W/m2, AM 1,5 and cells temperature of 25ºC. Measurement tolerance +/-3% (AAA Solar simulation -IEC 60.904-9-). All the information of this brochure may be amended without notice by Eurener.

Eurener_MEPV  108_ULTRA_450-460Wp_EN_JAN2024

eurener.com

contact@eurenerworld.com

+34 960 045 515

Calle Colón, 1-23

46004, Valencia. Spain

Manufacturing a better world

Since 1997 our main purpose has been to supply quality and long-lasting photovoltaic modules that allow us and future generations, to continue generating clean energy to take care of our planet

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals