BROAN CLLB1 Range Hood
Product Information
Specifications
- Product: Range Hood
- Series: CLLB1
- Model: Serial number: 99045653-005H
Safety
To ensure safe usage of the range hood, please observe the following safety precautions:
- Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
- Clean the ventilating fan frequently. Grease should not be allowed to accumulate on the fan, filters, or in exhaust ducts.
- Use proper pan size. Always use cookware appropriate for the size of the surface element.
Operation
To operate the range hood, follow these steps:
- Ensure the range hood is properly installed and connected to the power supply.
- Turn on the power switch to activate the range hood.
- Adjust the fan speed using the provided controls.
Cleaning and Maintenance
To keep your range hood clean and functioning properly, follow these cleaning and maintenance guidelines:
- Motors: Regularly inspect and clean the motors to remove any accumulated dust or debris.
- Grease Filters: Clean or replace the grease filters as recommended in the user manual.
- Non-Ducted Recirculation Filters: Clean or replace the non-ducted recirculation filters as recommended in the user manual.
- Fan Wheels: Inspect and clean the fan wheels to ensure smooth operation.
- Stainless Steel Cleaning: Use a mild stainless steel cleaner to clean the stainless steel surfaces of the range hood.
- Painted Finish Cleaning: Use a non-abrasive cleaner to clean the painted surfaces of the range hood.
Installation
Proper installation of the range hood is essential for its optimal
performance. Follow these steps for installation:
Recommended Tools and Accessories for Installation
Gather the following tools and accessories before starting the installation
process:
- [List of recommended tools and accessories]
Install Ductwork (Ducted Installations Only)
If your installation requires ductwork, follow these steps:
- [Steps for installing ductwork]
Prepare the Hood
Before installing the range hood, prepare it by following these steps:
- [Steps for preparing the range hood]
Prepare the Hood Location
Choose and prepare a suitable location for installing the range hood by
following these steps:
- [Steps for preparing the hood location]
EZ1 One-Person Installation
If you are installing the range hood by yourself, use the EZ1 brackets and
follow these steps:
- [Steps for EZ1 one-person installation]
Install the Hood (Standard Installation)
If you are not using the EZ1 brackets, follow these steps to install the range
hood:
- [Steps for standard installation]
Connect the Wiring
Properly connect the wiring of the range hood by following these steps:
- [Steps for connecting the wiring]
Install the Filters
Install the filters in the range hood by following these steps:
- [Steps for installing the filters]
FAQ
Q: Can I leave the surface units unattended at high settings?
A: No, it is not recommended to leave surface units unattended at high
settings as it may cause smoking and greasy spillovers that can ignite.
Q: How often should I clean the ventilating fan?
A: The ventilating fan should be cleaned frequently to prevent grease
accumulation. Refer to the user manual for specific cleaning instructions.
Q: What should I do in the event of a range top grease fire?
A: In the event of a range top grease fire, smother the flames with a
close-fitting lid, cookie sheet, or metal tray. Turn off the burner and be
careful to prevent burns. If the flames do not go out immediately, evacuate
and call the fire department.
READ AND SAVE THESE INSTRUCTIONS
! Intended for domestic cooking only !
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
Register your range hood online at www.broan.ca
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
-
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
-
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
-
Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
-
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection
Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. -
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
-
Ducted fans must always be vented to the outdoors.
-
Do not use this unit with any additional solid-state speed control device.
-
To reduce the risk of fire, use only metal ductwork.
-
This unit must be grounded.
-
As an alternative, this product may be installed with the UL-approved cord kit designated for the product, following instructions packed with the cord kit.
-
When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
- Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
- Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
- Clean ventilating fan frequently. Grease should not be allowed to accumulate on fan, filters or in exhaust ducts.
- Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
- SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray,then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
- NEVER PICK UP A FLAMING PAN — You may be burned.
- DO NOT USE WATER, including wet dishcloths or towels — This could cause a violent steam explosion.
- Use an extinguisher ONLY if:
- A. You own a Class ABC extinguisher and you know how to operate it.
- B. The fire is small and contained in the area where it started.
- C. The fire department has been called.
- D. You can fight the fire with your back to an exit.
Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
- For indoor use only.
- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
- To avoid motor bearing damage and noisy and/or unbalanced fan blade, keep drywall spray, construction dust, etc. off range hood.
- Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.
- For best capture of cooking fumes, the bottom of the hood MUST NOT BE LESS than 24” and at a maximum of 30” above the cooking surface.
- Always follows the cooking equipment manufacturer’s requirements regarding the ventilation needs.
- To reduce the risk of fire and to properly exhaust air, be sure to duct air outside — Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage.
- When installing, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
- Please read specification label on product for further information and requirements.
Operation
Always turn your hood on before you begin cooking to establish an air flow in
the kitchen.
Let the blower run for a few minutes to clear the air after you turn off the
range. This will help keep the whole kitchen cleaner and fresher.
Operate the hood as follows:
NOTE: At range hood start-up or after a power failure, a small icon (1) appears shortly (for ± 2 seconds) on LCD screen; this is normal.
BLOWER ACTIVATION/SPEED LEVEL CHANGE/FILTER INDICATOR RESET
When blowers are OFF, press on this push button to turn ON the blowers at the
last saved speed.
If there was no speed saved, the blowers will be set on LOW speed.
NOTE: When LOW speed is activated from OFF, the blowers start on MEDIUM
speed for a very short lapse of time, and then resume to LOW speed.
To change the blower speed, press on this push button again until the desired
speed is reached (from LOW to MEDIUM to HIGH speed to OFF). Each time a blower
speed is activated, a rotating blower icon appears on left side of LCD screen,
with dot(s) under it (the rotation speed shows the chosen speed: slow for LOW
with one dot, faster for MEDIUM with 2 dots and fastest for HIGH with 3 dots).
When blowers are on (no matter the speed level), press and hold this push
button until the blower icon disappears from the LCD screen; this will turn
off the blowers and save the blower speed chosen.
Heat Sentry™
This hood is equipped with a protective device that activates the blowers when
an abnormally high heat level is detected while the blowers are activated.
During the Heat Sentry activation, this device takes control of the blowers
and set them on MEDIUM speed while all dots under the blower icon blink.
However, the lights can be still controlled. The blowers will remain on MEDIUM
speed until the heat is back to normal, they then return to the speed
previously selected.
NOTE: When excessive heat is detected, Heat Sentry will shut off both blowers and lights while all dots under the blower icon will blink faster. Both blowers and lights will remain off until the ambient temperature cools down; the blowers will then start on MEDIUM speed (the lights can be controlled again). The blowers will remain on MEDIUM speed until the heat is back to normal, they then return to the speed previously selected.
NOTE: At range hood start-up or after a power failure, a small icon (1) appears shortly (for ± 2 seconds) on LCD screen; this is normal.
FILTER CLEANING REMINDER
This icon appears on LCD screen 30 seconds after turning OFF the blowers when
it is time to clean hood and filters (refer to Cleaning and Maintenance on
page 7). This happens every time the blowers are turned OFF until the filter
cleaning reminder has been reset. Once the cleaning is done, reset the filter
cleaning reminder by pressing on blower activation push button for 3 seconds
while the icon appears on LCD screen for 30 seconds.
DELAY OFF
When the blowers are on, press this button to activate the delay function.
This icon appears on LCD screen beside the blower icon to indicate the
function is on. The blowers will continue to operate for 10 minutes and then,
will shut off automatically (both blower and delay icons will disappear from
LCD screen). When Delay off is activated, it is possible to change the blower
speed by pressing on blower push button without affecting the remaining time
of the delay.
To cancel the delay off function before the end of the 10-minute cycle, press
again on delay off push button.
ON LIGHTING/LIGHT INTENSITY CHANGE
Press this push button to turn on the lights at the last saved intensity; the
light icon appears on right side of LCD screen and the number of dots below it
shows which light intensity is on (one dot for LOW, two dots for MEDIUM and
three dots for HIGH).
To change the light intensity, press the push button until the desired level
is reached (from HIGH intensity, pressing again will shut off the lights).
When lights are on (no matter the light intensity), press and hold this push
button until the light icon disappears from the LCD screen; this will shut off
the lights and save the chosen light intensity.
The LED modules included with this hood are the latest in LED cooktop
illumination technology specially designed to operate in the elevated
temperatures of cooking – offering bright lighting and lasting up to 25 times
as long as a standard bulb and greater reliability than typical replacement
LED bulbs.
MASTER ON/OFF
Press this push button to turn on the ligths and the blowers at the last saved
intensity. When either lights or blowers are ON, pressing on this push button
will memorize the current blower speed and lighting level prior to shut them
OFF.
Cleaning and Maintenance
Proper maintenance of the Range Hood will assure proper performance of the
unit.
MOTORS
The motors are permanently lubricated and never need oiling. If the motor
bearings make excessive or unusual noise, replace the motor with the exact
service motor. The fan wheel should also be replaced.
GREASE FILTERS
The grease filters should be cleaned frequently. Use a warm dishwashing
detergent solution.
Clean all-metal filters using a non-phosphate detergent. Discoloration of the
filters may occur if using phosphate detergents, or as a result of local water
conditions – but this will not affect filter performance. This discoloration
is not covered by the warranty. To minimize or prevent discoloration, hand
wash filters using a mild detergent.
NON-DUCTED RECIRCULATION FILTERS
The non-ducted recirculation filters should be changed every 3 to 6 months.
Replace more often if your cooking style generates extra grease, such as
frying and wok cooking. Refer to installation instructions included with non-
ducted recirculation filters.
FAN WHEELS
The center of the fan wheels should be cleaned frequently. Use a clean cloth
soaked with warm detergent solution.
STAINLESS STEEL CLEANING
Do:
- Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
- Always clean in the direction of original polish lines.
- Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
- You may also use a specialized household stainless steel cleaner.
Don’t:
- Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
- Use any harsh or abrasive cleansers.
- Allow dirt to accumulate.
- Let plaster dust or any other construction residues reach the hood. During construction/ renovation, cover the range hood to make sure no dust sticks to the stainless steel surface.
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be used close to a range.
PAINTED FINISH CLEANING:
Clean with warm water and mild detergent only. If discoloration occurs, use a
finish polish such as automotive polish. (DO NOT use rough abrasive cleaner or
porcelain cleaner.)
For ADA compliance installation guidelines, please type the model number into our website.
Recommended Tools and Accessories for Installation
- Measuring tape
- Phillips screwdriver no. 2
- Nutdriver or socket 11/32″
- Flat blade screwdriver (to open knockout holes)
- Drill, 1/8” drill bit and 1½” hole saw (to mark holes for ducting and cut electrical access hole)
- 7/64” drill bit (to drill holes for EZ1 brackets mounting screws)
- 7” round duct plate, not included (for 7’’ round vertical ducting installation, part no.: SR680508)
- Wood shims (2) and wood screws (4) (required for standard installation to framed cabinet)
- Saw (to cut holes for ducted application)
- Sheet metal shears (ducted installation only, for duct adjustment)
- Pliers (ducted installation only, for duct adjustment)
- Metal foil duct tape (for ducted applications)
- Scissors (to cut metal foil duct tape)
- Pencil
- Wire stripper
- Strain relief, 1/2” diameter (to secure house wiring cable to the hood)
- BP87Q Damper (needed if 7-in. round duct is used)
Install Ductwork (Ducted Installations Only)
NOTE: Distances over 30” are at the installer and user discretion.
-
Determine whether hood will discharge vertically (3¼” x 10”, 3¼” x 14” or 7” round),or horizontally (3¼” x 10” or 3¼” x 14” only).
-
Decide where the ductwork will run between the hood and the outdoors.
-
Choose a straight, short duct run to allow the hood to perform most efficiently. Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. When possible, use at least 2 foot straight runs before any turns. Larger ductwork may be required for best performance with longer duct runs.
NOTE: To use 6” round ducting, install a 3¼” x 10” to 6” round transition (not included). The performances may be affected. -
Install wall cap or roof cap (sold separately); ensure there is no leak in house insulation.
Connect metal ductwork to cap and work back towards the hood location. Use 2” metal foil duct tape to seal the joints between ductwork sections.
Contents
Before proceeding to the installation, check the contents of the box. If items
are missing or damaged, contact the manufacturer.
Make sure that the following items are included:
Prepare the Hood
-
If present, remove all protective polyfilm from the hood and/or parts.
-
Remove 2 screws from top of hood. Remove the 3¼’’ x 10’’ adapter and the 3¼’’ x 14’’ adapter frame from the back of hood. Keep the screws for further use.
-
Using the finger cup, remove the grease filters from the hood by pushing down 1 and tilting filters out 2.
-
Remove and set aside the damper flap (A). Remove the blower cover plate (in grey). Using a 11/32” nutdriver or socket, remove the lock nut retaining the flange of the cover plate to the inner back of hood (see inset). Remove the cover plate 7 retaining screws using a Phillips screwdriver, then set the blower cover along with its screws and nut aside.
-
Remove the parts bag, taped on the inner back of hood, near the left corner. Remove the EZ1 brackets from inside the hood by cutting off the tie wrap. Discard the tie wrap.
-
Remove Electrical Power Cable Knockout from top (vertical wiring) or back (horizontal wiring) of hood. For knockout removed from back of hood, install an appropriate strain relief, 1/2” diameter (not included). For knockout removed from top of hood, the strain relief will be installed later.
NON-DUCTED INSTALLATION ONLY -
Remove 3 screws retaining the recirculation cover plate to the hood. Discard this plate with its screws. Peel off and discard the membrane covering the recirculation grille, ensuring the openings are totally cleared.
3¼” x 14” DUCTED INSTALLATION ONLY -
Remove 3¼” x 14” vertical or 3¼” x 14” horizontal knockout plate as appropriate for your ducting method (see Figures 1 A and 1 B).
-
Assemble the 3¼” x 14” frame (removed in step 2) with the damper flap (removed in step 4) by following the instructions provided on a separate sheet. Attach the 3¼’’ x 14’’ Damper Assembly on top OR back of hood over the knockout opening using the screws removed in step 2. When installed, the 3¼” x 14” damper assembly must open as shown in Figure 2 B.
TIP: Insert a small length of duct over the 3¼” x 14” damper assembly and seal the joint using aluminum foil duct tape to ease connection with the house ductwork.
3¼” x 10” OR 7” ROUND DUCTED INSTALLATION ONLY- Remove 3¼” x 10” vertical, 3¼” x 10” horizontal (both are the rectangular central knockout plates, see hatched areas) or 7-inch round knockout plate as appropriate for your ducting method (see Figures 1 A and 1 B).
- Attach 3¼” x 10” Damper Assembly on top OR back of hood (if using 3¼” x 10” duct; shaded part in Figure 2 A below) or 7” Round Duct Plate (if using 7-inch round duct, Figure 3) over the knockout opening. When installed, the 3¼” x 10” damper assembly must open as shown in Figure 2 B.
NOTE: To accommodate off-center ductwork, the 7” round duct plate can be installed up to 1/2” on either side of the hood center.
TIP: Insert a small length of duct over the 3¼” x 10” damper assembly (for rectangular ducting) or 7” round (for round ducting) and seal the joint using aluminum foil duct tape to ease connection with the house ductwork.
Prepare the Hood Location
NOTE: Before starting installation, read all the steps of these
instructions.
Use the illustration below to identify your kitchen cabinet type.
This manual covers 2 kinds of installation: the standard (without EZ1
brackets) and the EZ1 one-person installation system (using included template
and brackets).
For the standard installation, go to page 19.
EZ1 one-person installation system
EZ1 installation is designed for use with kitchen cabinets that have the same
width designation as the range hood width. If the cabinet is greater than 1/2”
wider than the range hood width, please use the standard installation method.
-
Use the proper template for vertical OR horizontal disharge (included) for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring. If replacing a hood and plan to use the existing duct and electrical, steps 2 to 5 may not be necessary. If so, skip to step 6.
-
Measure and mark the hood center line on cabinet bottom.
-
Align the center line on template with the hood center line marked on the bottom of the cabinet, placing the edge (where indicated) of the template against back wall. When using with framed cabinet for vertical exhaust installation, fold over rear edge of template equal to the depth of the cabinet frame at the wall (use graduations on template, C locations on template). Tape the template in place.
NOTE: When facing the installation, A and B (on template) must be at right. -
Drill a 1/8” dia. pilot hole for house wiring, at B location on template.
-
Use a sharp pencil or 1/8” drill bit to mark the locations for the appropriate duct access holes (16 locations for 7” round duct, or 4 corner locations for rectangular duct). Remove the template.
-
Draw the border for the exhaust ducting by linking its marks (16 for round duct and 4 for rectangular duct), then cut the opening in the cabinet bottom (vertical exhaust) or in the wall (horizontal exhaust). Drill the house wiring hole by using a 1½” hole saw centered with the pilot hole previously made in 4.
-
Install the proper installation brackets according to the type of cabinet (framed or frameless).
See below.
FRAMED CABINET
Refer to the mHaAr01k13ing on brackets to determine the correct installation side and orientation.
- Mate the corresponding bracket to the cabinet side frame, while placing rear end of bracket against the wall. Use a pencil to mark 3 holes (there are 6 holes but only 3 are necessary).
- Remove the bracket. Using a 7/64” drill bit, drill 3 holes where marked.
- Assemble the bracket to the side frame using a Phillips screwdriver and 3 provided no. 8 x 5/8” wood screws. Repeat for the other side frame.
FRAMELESS CABINET
Refer to the marking on brackets to determine the correct installation side and orientation.
- Align the corresponding bracket to the cabinet side, while placing rear end of bracket against the wall. Draw a line on the outer edge of the bracket (as shown).
- Slide the bracket towards the center of cabinet and align the outside edge of the bracket with the marked line, keeping the rear end edge leaning on the wall.
- Use a pencil to mark 3 holes.
- Remove the bracket. Using a 7/64” drill bit, drill 3 holes where marked.
- Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood screws. Repeat for the other cabinet side.
Install the Hood (EZ1 Bracket)
NOTE: The following procedure applies to both frame or frameless cabinet installations.
-
Run house power cable between service panel and hood location.
-
There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B, on front C and D on illustration below); these holes allow the range hood to hang on the brackets (previously installed).
HORIZONTAL EXHAUST INSTALLATION -
Temporarily hang the hood on the brackets using its (2) recessed REAR HOLES (A and B).
While holding the hood, run the house power cable into the hood through the strain relief previously installed in step 6 on page 11. -
Unhook the rear holes from the brackets and hang the hood using its (2) recessed FRONT HOLES (C and D). While holding the hood, go to step 6.
VERTICAL EXHAUST INSTALLATION AND NON-DUCTED INSTALLATION ONLY -
Hang the hood on the brackets using the (2) recessed FRONT HOLES (C and D). While holding the hood, tighten an appropriate strain relief, 1/2” diameter (not included) to the power cable, then insert the strain relief in the knockout hole.
DUCTED INSTALLATION ONLY -
Connect ductwork to hood and use metal foil duct tape to make joints secure and air-tight.
Make sure the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely. -
For framed cabinet, secure the hood to the EZ1 brackets using four (4) no. 8-18 x 1/2” metal screws (included in parts bag). Insert two (2) screws per side, in the slots (as shown in insets on illustration below).
-
For frameless cabinet, secure the hood to the cabinet using four (4) no. 8 x 5/8” round head wood screws (included in parts bag). Insert two (2) screws per side, in the slots (as shown in insets on illustration below).
-
Attach power cable to the hood using the strain relief.
Standard Installation (without EZ1 brackets)
- Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring.
- Install half-way two (2) ROUND HEAD no. 8 x 5/8” mounting screws into shims/cabinet, according to the proper diagram above, the other 2 ROUND HEAD no. 8 x 5/8” mounting screws will be used later. (Mounting screws are included in parts bag, but wood shims and shim mounting screws are not included.)
Install the Hood (Standard Installation)
NOTE: Two installers are recommended because of the weight of this hood.
-
Run house power cable between service panel and hood location. For hood with power cable access located on back of hood, run the house power cable into the hood through the strain relief previously installed in step 6 on page 11. For hood with power cable access located on top, tighten the strain relief to the power cable before inserting the strain relief in the knockout hole.
-
Hang hood from two (2) rear mounting screws previously installed. Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood. Tighten screws securely and maintain a hold on the hood until completing step 3.
-
Secure the hood to the cabinet using two (2) no. 8 x 5/8” round head wood screws (included in parts bag). Insert one (1) screw per side, in the slots (as shown below). Attach power cable to the hood using the strain relief.
DUCTED INSTALLATION ONLY -
Connect ductwork to hood and use metal foil duct tape to make joints secure and air-tight.
Make sure the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely.
Connect the Wiring
WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel
in accordance with all applicable codes and standards.
Before connecting wires, switch power off at service panel and lock service
disconnecting means to prevent power from being switched on accidentally.
- Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
- Reinstall the blower cover plate (shaded part on illustration above) using the lock nut and the 7 screws previously removed in step 4 on page 10. Pay attention to screw 1 location; from back of hood point of view, it must be located on right side of the lock nut (see inset).
Install the Filters
Ducted Installation Only:
Re-install grease filters removed in step 3 , page 10, under “Prepare the
Hood”.
Non-ducted Installation Only:
Purchase two non-ducted filters from your local distributor or retailer (see
product specification label for filter type). Attach the non-ducted filters
following instructions packed with the non-ducted filters.
WIRING DIAGRAM
CLLB1 SERIES (second generation)
CLLB1 SERIES
First Generation: Serial number 121810002693 and previous.
k ey
no .
|
p art no .
|
d eScription
| Q uantity
---|---|---|---
30″
W hite
| 30″
S tainleSS
1| S97020030| recirculation cover plate, White (including screWs)| 1|
S97020031| recirculation cover plate, stainless steel (including screWs)| | 1
2| S97020469| 3¼” x 14” damper ass’y (including screWs)| 1| 1
3| S97020534| 3¼” x 10” damper assembly (including screWs)| 1| 1
4| S97020416| capacitor (including tie Wrap)| 2| 2
5| S97020797| autotransformer (With screWs)| 1| 1
6| S97020415| bloWer ass’y cW (including item 4 and hardWare)| 1| 1
7| S97021338| bottom covers (With inlets)| 1| 1
8| S97020204-002| grease filter – hybrid -type c5 (set of 2)| 1| 1
9| S97020417| bloWer ass’y ccW (including item 4 and hardWare)| 1| 1
10| S97020444| led module (pair)| 1| 1
11| S97020459| lcd control (With screWs)| 1| 1
12| S97021392| transformer kit, 24 v 18 va (With screWs)| 1| 1
*| S97020796| Wire harness With autotransformer and fuse| 1| 1
|
S97020360
| parts bag including: 4 metal screWs no. 8-18 x 1/2”, 6 round head no. 8 x 5/8” Wood screWs,
6 no. 8 x 1/2” countersunk Wood screWs
|
1
|
1
| S97020466| non-ducted filter – type xc (set of 2) (non-ducted
installation only)| 1| 1
| S99527587| non-ducted filter clip kit (incl. 4 clips)| 1| 1
*| S97020470| easy install kit (including hardWare)| 1| 1
Replacement Parts and Repairs
In order to ensure your unit remains in good working condition, you must use
Venmar Ventilation ULC genuine replacement parts only. Venmar Ventilation ULC
genuine replacement parts are specially designed for each unit and are
manufactured to comply with all the applicable certification standards and
maintain a high standard of safety. Any third party replacement part used may
cause serious damage and drastically reduce the performance level of your
unit, which will result in premature failing. Venmar Ventilation ULC
recommends to contact a certified service depot for all replacement parts and
repairs.
CLLB1 SERIES
Second Generation: Serial number 121810002694 and up.
k ey
no .
|
p art no .
|
d eScription
| Q uantity
---|---|---|---
30″
W hite
| 30″
S tainleSS
1| S97020030| recirculation cover plate, White (including screWs)| 1|
S97020031| recirculation cover plate, stainless steel (including screWs)| | 1
2| S97020469| 3¼” x 14” damper ass’y (including screWs)| 1| 1
3| S97020534| 3¼” x 10” damper assembly (incl. screWs)| 1| 1
4| S97021325| capacitor (including tie Wrap)| 2| 2
5| S97021328| bloWer ass’y cW (including items 4, 6 and hardWare)| 1| 1
6| SR99420635| clip for fanpeller| 2| 2
7| S97021339| bottom covers (With inlets)| 1| 1
8| S97020204-002| grease filter – hybrid -type c5 (set of 2)| 1| 1
9| S97021329| bloWer ass’y ccW (including items 4, 6 and hardWare)| 1| 1
10| S97020444| led module (pair)| 1| 1
11| S97020459| lcd control (With screWs)| 1| 1
12| S97021392| transformer kit, 24 v 18 va (With screWs)| 1| 1
*| S97020454| Wire harness| 1| 1
|
S97020360
| parts bag including: 4 metal screWs no. 8-18 x 1/2”, 6 round head no. 8 x 5/8” Wood screWs,
6 no. 8 x 1/2” countersunk Wood screWs
|
1
|
1
| S97020466| non-ducted filter – type xc (set of 2) (non-ducted
installation only)| 1| 1
| S99527587| non-ducted filter clip kit (incl. 4 clips)| 1| 1
*| S97020470| easy install kit (including hardWare)| 1| 1
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use
Venmar Ventilation ULC genuine replacement parts only. Venmar Ventilation ULC
genuine replacement parts are specially designed for each unit and are
manufactured to comply with all the applicable certification standards and
maintain a high standard of safety. Any third party replacement part used may
cause serious damage and drastically reduce the performance level of your
unit, which will result in premature failing. Venmar Ventilation ULC
recommends to contact a certified service depot for all replacement parts and
repairs.
Limited Warranty
Warranty Period and Exclusions: Venmar Ventilation ULC (the “Company”)
warrants to the original consumer purchaser of its product (“you”) that the
product (the “Product”) will be free from material defects in the Product or
its workmanship for a period of one (1) year from the date of original
purchase (or such longer period as may be required by applicable law). For
Range Hood Product that includes built-in LED modules, the Company warrants
the LED modules and driver to be free from material defects for a period of
three (3) years from the date of purchase.
The limited warranty period for any replacement parts provided by the Company
and for any Products repaired or replaced under this limited warranty shall be
the remainder of the original warranty period (or such longer period as may be
required by applicable law).
This warranty does not cover fluorescent lamp starters, tubes, halogen and
incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and other
accessories for ducting that may be purchased separately and installed with
the Product. This warranty also does not cover (a) normal maintenance and
service, (b) normal wear and tear, (c) any Products or parts which have been
subject to misuse, abuse, abnormal usage, negligence, accident, improper or
insufficient maintenance, storage or repair (other than repair by the
Company), (d) damage caused by faulty installation, or installation or use
contrary to recommendations or instructions, (e) any Product that has been
moved from its original point of installation, (f) damage caused by
environmental or natural elements, (g) damage in transit, (h) natural wear of
finish, (i) Products in commercial or nonresidential use, or (j) damage caused
by fire, flood or other act of God or (k) Products with altered, defaced or
removed serial numbers. This warranty covers only Products sold to original
consumers in Canada by the Company or its Canadian distributors authorized by
the Company.
This warranty supersedes all prior warranties and, subject to applicable law,
is not transferable from the original consumer purchaser.
No Other Warranties: This Limited Warranty contains the Company’s sole
obligation and your sole remedy for defective products. The foregoing
warranties are exclusive and in lieu of any other warranties and conditions,
express or implied.
THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES AND CONDITIONS, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES AND CONDITIONS IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. To the extent that applicable law prohibits the exclusion of implied warranties or conditions, the duration of any applicable implied warranty or condition is limited to the period specified for the express warranty above. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it and shall not be construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be
interpreted in such manner as to be effective and valid under applicable law,
but if any provision is held to be prohibited or invalid, such provision shall
be ineffective only to the extent of such prohibition or invalidity, without
invalidating the remainder of such provision or the other remaining provisions
of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at
its option, provide replacement parts for, or repair or replace, without
charge, any Product or part thereof, to the extent the Company finds it to be
covered by and in breach of this limited warranty under normal use and
service. The Company will ship the repaired or replaced Product or replacement
parts to you at no charge. You are responsible for all costs for removal,
reinstallation and shipping, insurance or other freight charges incurred in
the shipment of the Product or part to the Company. If you must send the
Product or part to the Company, as instructed by the Company, you must
properly pack the Product or part—the Company is not responsible for damage in
transit. The Company reserves the right to utilize reconditioned, refurbished,
repaired or remanufactured Products or parts in the warranty repair or
replacement process. Such Products and parts will be comparable in function
and performance to an original Product or part and warranted for the remainder
of the original warranty period (or such longer period as may be required by
applicable law).
Company reserves the right, in its sole discretion, to refund the money
actually paid by you for the Product in lieu of repair or replacement. If the
Product or component is no longer available, replacement may be made with a
similar product of equal or greater value, at Company’s sole discretion. This
is your sole and exclusive remedy for breach of this limited warranty.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS,
OR REPAIR,
REPLACE OR REFUND, AT THE COMPANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE PRODUCT, ITS USE OR PERFORMANCE. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if the Product does not work properly.
THE COMPANY SHALL NOT BE LIABLE TO YOU, OR TO ANYONE CLAIMING UNDER YOU, FOR ANY OTHER OBLIGATIONS OR LIABILITIES, INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS OR LIABILITIES ARISING OUT OF BREACH OF CONTRACT OR WARRANTY, NEGLIGENCE OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY, WITH RESPECT TO THE PRODUCT OR THE COMPANY’S ACTS OR OMISSIONS OR OTHERWISE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from jurisdiction to jurisdiction. The disclaimers, exclusions, and limitations of liability under this warranty will not apply to the extent prohibited by applicable law.
This warranty covers only replacement or repair of defective Products or parts
thereof at the Company’s main facility and does not include the cost of field
service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms,
limitations or exclusions of this limited warranty will not constitute a
waiver of such terms, limitations or exclusions, nor will such assistance
extend or revive the warranty. The Company will not reimburse you for any
expenses incurred by you in repairing or replacing any defective Product,
except for those incurred with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a)
notify the Company at the address or telephone number stated below within
seven (7) days of discovering the covered defect, (b) give the model number
and part identification and (c) describe the nature of any defect in the
Product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date. If you cannot provide a copy of the
original written limited warranty, then the terms of the Company’s most
current written limited warranty for your particular product will control. The
most current limited written warranties for the Company’s products can be
found at www.broan.ca. Venmar Ventilation ULC, 550
Lemire Blvd., Drummondville, Québec, Canada J2C 7W9
www.broan.ca
1-877-896-1119
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>