Altronix T1M1LCK1 Mercury Wired Kits Installation Guide
- June 16, 2024
- Altronix
Table of Contents
Altronix T1M1LCK1 Mercury Wired Kits
Specifications
- Model: T1M1LCK1
- Number of Doors: 4
- Fused Outputs: Yes
- Accommodates: 1 Intelligent Dual Reader Controller and 1 Dual
Reader Interface Module
Product Overview
The Altronix Trove Plus kits are pre-wired, pre-assembled kits that include
the Trove1M1 enclosure/backplane with a factory-installed Altronix power
supply/charger and sub-assemblies.
These kits also come with wire harnesses and finger duct for easy
installation.
Configuration Chart
Altronix Model Number| T1M1LCK1| T1M1LCK2| T1M1LCK3| T1M1LCK1D| T1M1LCK2D|
T1M1LCK3D
---|---|---|---|---|---|---
115VAC 60Hz Input Current (A)| 3.0| | | | |
Power Supply Board Input Fuse Rating| 5A/250V| | | | |
Power Supply Board Battery Fuse Rating| Nominal DC| | | | |
Output Voltage Range (VDC)| | | | | |
Maximum Supply Current for Main Outputs on Power Supply board
and ACM4(CB) Access Power Controller’s outputs| | | | | |
ACM4(CB) PDS8(CB) PDS8(CB) Fail- ACM4(CB) Board Board Board
Safe/ Board Output Input Output Fail- Input Fuse Fuse Fuse Secure
Fuse (PTC) (PTC) (PTC) Outputs Rating Rating Rating Rating| 15A/32V| | | | |
Access & Power Integration
Altronix/Mercury Wired Kits
Models Include
T1M1LCK1
4 Door Kit with Fused Outputs
Accommodates one (1) Intelligent Dual Reader Controller and one (1) Dual
Reader Interface Module.
T1M1LCK2
2 Door Kit with Fused Outputs
Accommodates one (1) Intelligent Controller and
one (1) Dual Reader Interface Module.
T1M1LCK3
4 Door Kit with Fused Outputs
Accommodates up to two (2) Dual Reader Interface Modules.
Each fully assembled kit includes
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) AL400ULXB2 – Power Supply/Charger
- One (1) ACM4 – Fused Access Power Controller
- One (1) PDS8 – Dual Input Fused Power Distribution Module
- One (1) VR6 – Voltage Regulator
- One (1) Rocker Switch Bracket with One (1) Rocker Switch (Not evaluated by UL)
- Wire harnesses and management
T1M1LCK1D
4 Door Kit with PTC Outputs
Accommodates one (1) Intelligent Dual Reader Controller and one (1) Dual
Reader Interface Module.
T1M1LCK2D
2 Door Kit with PTC Outputs
Accommodates one (1) Intelligent Controller and one (1) Dual Reader Interface
Module.
T1M1LCK3D
4 Door Kit with PTC Outputs
Accommodates up to two (2) Dual Reader Interface Modules.
Each fully assembled kit includes
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) AL400ULXB2 – Power Supply/Charger
- One (1) ACM4CB – PTC Access Power Controller
- One (1) PDS8CB – Dual Input PTC Power Distribution Module
- One (1) VR6 – Voltage Regulator
- One (1) Rocker Switch Bracket with One (1) Rocker Switch (Not evaluated by UL)
- Wire harnesses and management
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides
for further information.
Installation Guide
All registered trademarks are property of their respective owners.
Rev. 020922
Installing Company: _____ Service Rep. Name:
Address: _____ Phone #:
Overview
Altronix Trove Plus kits are pre-wired, pre-assembled and consist of Trove1M1 enclosure/backplane with factory installed Altronix power supply/charger and sub-assemblies, wire harnesses and finger duct.
Configuration Chart
Altronix Model Number| 115VAC
60Hz
Input Current (A)
| Power Supply Board Input Fuse Rating| Power Supply Board Battery Fuse Rating| Nominal DC
Output Voltage Range (VDC)
| Maximum Supply Current for Main Outputs on Power Supply board and ACM4(CB) Access Power Controller’s outputs| Fail- Safe/ Fail- Secure Outputs| ACM4(CB)
Board Input Fuse Rating
| ACM4(CB)
Board Output Fuse (PTC)
Rating
| PDS8(CB)
Board Input Fuse (PTC)
Rating
| PDS8(CB)
Board Output Fuse (PTC)
Rating
---|---|---|---|---|---|---|---|---|---|---
T1M1LCK1| ****
3.0
| 5A/
250V
| 15A/
32V
| 20.17-
26.4
| 24VDC @ 3.8A| 4| 10A/
32V
| 3A/
32V
| 10A/
32V
| 3A/
32V
T1M1LCK2
T1M1LCK3
T1M1LCK1D| 10A/
32V
| 2.5A| 9A| 2.5A
T1M1LCK2D
T1M1LCK3D
Installation Instructions
Wiring methods shall be in accordance with the National Electrical Code/NFPA
70/ANSI, and with all local codes and authorities having jurisdiction. Product
is intended for indoor use only.
-
Remove backplane from enclosure. Do not discard hardware.
-
Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws; level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners.
Place the enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws. -
Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
-
Mount Mercury modules to backplane(s), refer to page 3.
-
Refer to the ULXB Power Supply/Charger Installation Guide for AL400ULXB2 and corresponding Installation Guides for PDS8(CB), VR6, and ACM4(CB) for further installation instructions.
Hardware
T1M1LCK1(D): Configuration of Mercury Boards
- Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 3, pg. 4).
- Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models
Mercury Access Controller | Pem Mounting |
---|---|
LNL-2220 / LP1502 / LP4502 | A |
LNL-1320 / MR52 | B |
T1M1LCK2(D): Configuration of Mercury Boards
- Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 3, pg. 4).
- Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models
Mercury Access Controller | Pem Mounting |
---|---|
LNL-3300 / LP2500 | A |
LNL-1320 / MR52 | B |
T1M1LCK3(D): Configuration of Mercury Boards
- Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 3, pg. 4).
- Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models
Mercury Access Controller | Pem Mounting |
---|---|
LNL-1320 / MR52 | A |
LNL-1320 / MR52 | B |
Trove1 Enclosure Dimensions
(H x W x D approximate): 18” x 14.5” x 4.625” (457mm x 368mm x 118mm)
Altronix is not responsible for any typographical errors. Product
specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA | phone:
718-567-8181 | fax:
718-567-9056
- website : www.altronix.com
- E – mail : info@altronix.com
- Lifetime Warranty IIT1M1LCK Series
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>