Altronix Trove2HN2 Honeywell NetAXS Backplane Installation Guide

October 27, 2023
Altronix

Altronix Trove2HN2 Honeywell NetAXS Backplane

Trove2HN2

  • Trove2 enclosure with Altronix/Honeywell NetAXS backplane (THN2)

THN2

  • Altronix/Honeywell NetAXS backplane only

 Overview:

Trove2HN2 accommodates various combinations of Honeywell NetAXS boards with or without Altronix power supplies and accessories for access systems.

Specifications

Trove2HN2
Trove2 enclosure with THN2 Altronix/Honeywell backplane.

  • Includes: tamper switch, cam lock, mounting hardware.
  • 16 Gauge enclosure with ample knockouts for convenient access.
    Enclosure Dimensions (H x W x D): 27.25″ x 21.75″ x 6.5″ (692.2mm x 552.5mm x 165.1mm). Accommodates up to four (4) 12VDC/7AH batteries.

THN2
THN2 Altronix/Honeywell backplane.

  • 16 Gauge backplane.
  • Includes mounting hardware.
    Dimensions (H x W x D): 25.375″ x 19.375″ x 0.3125″ (644.6mm x 492.1mm x 7.9mm).

THN2 accommodates a combination of the following:
Altronix:

  • Up to four (4) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or eFlow104NB. · Up to four (4) ACM8(CB) or ACM8S(CB).
  • Up to three (2) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), or VR6.

Honeywell:

  • Up to four (4) NX4PCB access control panels.
  • Up to eight (8) NetAXS-123 access control panels.
  • Up to eight (8) NXD1 or NXD2 add-on boards.
  • Up to four (4) NX4IN or NX4OUT boards.

Agency Listings

  • UL 294 – 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II. Stand-by Power Level I if no battery is supplied.
  • This Class B digital apparatus complies with Canadian ICES-003.
  • CE European Conformity.

Installation Instructions

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having juris- diction. Product is intended for indoor use only.

  1. Remove backplane from enclosure. Do not discard hardware.
  2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws; level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.
  3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) Fig. 1 in desred location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2″ from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. Enclosure To activate alarm signal open the door of the enclosure .
  4. Mount Altronix/Honeywell boards to backplane, refer to pages 3-6.

Installation Instructions for Altronix Power Supplies and Sub-Assemblies

to THN2

  1. Fasten spacers (provided) into pem configuration (A) or (B) of backplane (Fig. 2, pg. 3)
  2. Mount boards to spacers utilizing 5/16″ pan head screws (provided) (Fig. 2a, pg. 3).
  3. Mount backplane to enclosure with hardware.

Access Controller Position Chart for the Following Models

Altronix Board|

Pem Mounting

---|---
Altronix Power Supply/Charger or Sub-Assembly|

Altronix Sub-Assembly|

Fig.2

Installation Instructions for Honeywell NX4PCB to THN2:

  1. Fasten spacers (provided) to appropriate pems on backplane (Fig. 3, pg. 4).

  2. Mount boards to spacers utilizing 5/16″ pan head screws (provided) (Fig. 3a, pg. 4).
    Note: Honeywell NX4PCB modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 3 below.

  3. Mount backplane to enclosure with hardware.

Installation Instructions for Honeywell NetAXS-123 with/without NXD1/NXD2

to THN2:

  1. Fasten spacers (provided) to appropriate pems on backplane (Fig. 4, pg. 5).

  2. Mount boards to spacers utilizing 5/16″ pan head screws (provided) (Fig. 4a, pg. 5).
    Note: Honeywell NetAXS-123 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 4 below. In order to properly mount and connect NXD1/NXD2 do the following: Pem – prior to mounting on backplane, attach NXD1/NXD2 to the NetAXS-123 Spacer by connecting the multi-pin connector on the bottom of NXD1/NXD2 to the multi-pin jack on NetAXS-123. Make sure that pre-installed bump screws on NXD1/NXD2 go through the corresponding holes in NetAXS-123. – secure NXD1/NXD2 to NetAXS-123 using pre-installed bump screws Honeywell Pan Head Access Controller Screw Backplane and included spacers (Fig. 4b, pg. 5).- after NXD1/NXD2 is firmly attached and connected to NetAXS-123, follow steps 1 and 2 above to mount them onto THN2.

  3. Mount backplane to enclosure with hardware.

Installation Instructions for Honeywell NX4IN or NX4OUT to THN2:

  1. Fasten spacers (provided) to appropriate pems on backplane (Fig. 5, pg. 6).
  2. Mount boards to spacers utilizing 5/16″ pan head screws (provided) (Fig. 5a, pg. 6).
  3. Mount backplane to enclosure with hardware.

THN2 Dimensions

THN2 Dimensions (H x W x D):
25.375” x 19.375” x 0.3125” (644.6mm x 492.1mm x 7.9mm)

Trove2HN2 Enclosure Dimensions

Trove2HN2 Enclosure Dimensions (H x W x D approximate):
27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm)

Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: info@altronix.com
IITrove2HN2 / THN2

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals