VOLTPEN Non Contact Dual Range Voltage Tester Pen User Manual
- June 16, 2024
- VOLTPEN
Table of Contents
VOLTPEN – USER MANUAL
Safety instructions
WARNING! To avoid possible electric shock or personal injury:
- Please use this tester strictly according to this instructions, otherwise, the protection function provided by tester may be affected.
- Do not use if the power indicator is not on.
- Before use, test on the known power to ensure that the product is good.
- When using this tester, there may still be voltage even if there is no sound or light alarm. The tester only indicates the effective voltage when the AC voltage produces an electrostatic field with sufficient strength.
- If the field strength is very low, the tester may not be able to detect it. The tester may be affected by the following factors, including, but not limited to:Shielded wire / cable, Thickness and type of insulation, Distance from the voltage source、Complete insulating, Differences in socket design, etc.
- Do not use if the tester is damaged or the tester is not working properly. Before use, check that the probe is cracked or broken. If in doubt, please timely repair tester.
- Please do not apply the rated voltage above the mark on the tester.
- To test AC voltage above 30V, special care must be taken in case of electric shock.
- Comply with local and national safety regulations.
- Use proper protective equipment in accordance with local or national regulations.
Instrument description
- Probe (NCV induction head)
- Induction voltage indicator light
- Torch lamp
- High signal intensity indicator
- Medium signal intensity indicator
- Low signal intensity indicator
- The power key, with power indicator
- Torch key
- The battery cover
Operation instructions
-
Turn on / off tester
Turn on:Press the power key greater than 1 second, the power indicator light is lit.
Turn off:Press the power key, power indicator lights off. -
Turn on / off torch
Turn on:Press the torch key to turn on the torch.
Turn off:Press the torch key, the torch turns off.
If the torch doesn’t turn off, it will turn off automatically in about 5 minutes. -
AC voltage detection
The probe tester inserted into the power socket or close to the live wire,When the tester detects the AC voltage signal, the induction voltage signal lamp flashes. According to the detected signal strength, the tester can illuminate the corresponding signal intensity indicator (high, middle, low). At the same time, the buzzer sends out different alarm sounds. When the AC voltage signal is sensed, Low signal intensity indicator is lit;When sensing a higher AC voltage signal,Light up the signal intensity indicator (middle, low) at the same time;When the highest AC voltage signal is sensed, the signal intensity indicator (high, middle, low) is also lit. -
Zero/live wire judgment
Try to separate the two wires to be detected as far as possible,Then close the wire with the probe of the tester, If it is a socket, insert the probe into the socket,One of the strong signals detected by a tester is live wire, a weak or no inductive signal is zero wire. -
Auto Power Off
When the tester does not operate for about 5 minutes and the voltage signal is not detected, the tester will turn off automatically. -
Low battery indication
When the battery voltage is lower than about 2.6V, the power indicator flashes 3 times, and the buzzer beeps and shuts off automatically. Please replace the battery in time.
Specifications
AC voltage range | About 12 ~1000V |
---|---|
Frequency | 50 Hz /60Hz |
Alarm mode | Sound and light alarm |
Torch | White LED illumination lamp |
Auto power off | yes |
Low battery indication | yes |
Zero/live wire judgment | According to the signal strength, strong signal is |
live wire
NCV intensity| Selecting 3 types of sensitivity automatically (low, mid, high)
NCV intensity indication| The instrument uses the alarm sound of different
frequency and LED
lamp of different color to indicate low, moderate or high sensitivity
Service temperature| 0~40℃
Storage temperature| -10~50℃
Altitude| <2000m
Security level| CE CAT.III 1000V /CAT.IV 600V
Power| 2×1.5V AAA batteries
Size| 156mm×20mm×20mm
Weight| About 45g
Battery replacement:
As per the diagram below:
- Rotate the battery cover
- Take out the used battery
- Put new battery in as per battery anode and cathode indication.
Warning: To avoid electric shock, do not use this instrument before the
battery cover is replaced..
Battery rotation direction as indicated
INSTRUCTIONS FOR RECYCLING AND DISPOSAL:
This label means that the product cannot be disposed of as other
household waste throughout the EU. To prevent potential damage to the
environment or human health from uncontrolled waste disposal. Recycle
responsibly to promote the sustainable use of material resources. If you want
to return a used device, use the drop-off and collection system, or contact
the retailer from whom you bought the product. The retailer can accept the
product for environmentally safe recycling.
A declaration by the manufacturer that the product complies with the
requirements of the applicable EU Directives.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>