Altronix T1KE3F4V Kisi Access and Power Integration Kit Installation Guide

June 16, 2024
Altronix

Altronix T1KE3F4V Kisi Access and Power Integration Kit Installation

Guide

Access & Power Integration

T1HCK3F
Up to 8 Door Kit
Fully assembled kit includes:

  • Trove1 enclosure with THC1 Altronix/Hartmann Controls backplane
  • One (1) eFlow6NB – Power Supply/Charger

T1HCK3F4
Up 8 Door Kit with Fused Outputs
Fully assembled kit includes:

  • Trove1 enclosure with THC1 Altronix/Hartmann Controls backplane
  • One (1) eFlow6NB – Power Supply/Charger
    • One (1) ACM4 – Fused Access Power Controller

All components of these Trove kits are UL Listed as sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.

Installation Guide

All registered trademarks are the property of their respective owners.

Rev. T1HC052820
Installing Company: _____ Service Rep. Name:


Address: _____ Phone #:


Overview:

Altronix/Hartmann Controls Trove kits are pre-assembled and consist of a Trove enclosure with factory-installed Altronix power supply/chargers and sub- assemblies. Each kit also accommodates one (1) Hartmann Controls PRS_Master board and up to four (4) PRS_TDM or PRS_IO8 boards.

Configuration Chart:

Altronix
Model Number| 120VAC 60Hz Input
Current (A)| ewer Supply Board
put Fuse Rating| | Nominal DC Output Voltage Options| Maximum
Supply Current for
Main and
Aux. Outputs on Power
Supply board and
ACM4 Access Power
Controller’s
outputs (A)| Fail-Safe/Fail-Secure or Dry Form “C”
Outputs| put (A)| ;M4 Board
put Fuse Rating| ACM4 Board Output Fuse Rating
---|---|---|---|---|---|---|---|---|---
[DC]| [AUX]
Power Supply Bc
Battery Fuse Rat| 12VDC
Output
Range
(V)| 24VDC
Output
Range
(V)| 12VDC
Output
Range
01)| 24VDC
Output
Range
(V)
|
T1HCK3F| 4.| 5A/
250V| 15A/
32V| Flow6NB
e| 12 or 24VDC @ 6A| —| —| —| —
10.0-
13.2| 20.19-
26.4| 10.03-
13.2| 20.19-
26.4
T1HCK3F4| 4.| 5A/
250V| 15N
32V| eFlow6NB| 12VDC @ 5.4A
or
24VDC @ 5.7A| 4| 3.| 10A/
32V| 3N
32V
10.0-
13.2| 20.19-
26.4| 10.03-
13.2| 20.19-
26.4

Hardware and Accessories:

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
The product is intended for indoor use only.

  1. Remove backplane from the enclosure. Do not discard hardware.

  2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding.  Place the enclosure’s upper keyholes over the three upper screws; level and secure.
    Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install
    the three fasteners. Place the enclosure’s upper keyholes over the three upper screws.
    Install the three lower screws and make sure to tighten all screws.

  3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in the desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect the tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate the alarm signal open the door of the enclosure.

  4. Mount Hartmann Controls boards to the backplane, refer to pages 3-4.

  5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB and
    Sub-Assembly Installation Guide for ACM4 for further installation instructions.

T1HCK3F: Configuration of Hartmann Controls Boards:

  1. Align the Hartmann Controls boards on the backplane to match the boards’ mounting holes with the corresponding poems.

  2. Fasten spacers (provided) to poems that match the hole pattern for Hartmann Control boards (Fig. 2, 2a, pg. 3).
    Note: Hartmann Controls boards must be properly grounded.
    Please use provided metal spacers for the lower right mounting holes (Fig. 2, pg. 3).

  3. Mount Hartmann Controls boards to spacers utilizing provided 5/16” pan head screws (Fig. 2a, pg. 3).

    1. Fasten backplane to Trove1 enclosure utilizing lock nuts (provided).

Fig. 2 – T1HCK3F Configurations

T1HCK3F4: Configuration of Hartmann Controls Boards:

  1. Align the Hartmann Controls boards on the backplane to match the boards’ mounting holes with the corresponding poems.

  2. Fasten spacers (provided) to poems that match the hole pattern for Hartmann Control boards (Fig. 3, 3a, pg. 4).
    Note: Hartmann Controls boards must be properly grounded.
    Please use provided metal spacers for the lower right mounting holes (Fig. 3, pg. 4).

  3. Mount Hartmann Controls boards to spacers utilizing provided 5/16” pan head screws (Fig. 3a, pg. 4).

    1. Fasten backplane to Trove1 enclosure utilizing lock nuts (provided).

Fig. 3 – T1HCK3F4 Configurations
Notes:

eFlow Power Supply/Chargers can be Controlled and Monitored while Reporting Power/Diagnostics from Anywhere over the Network…

LINQ2 – Network Communication Module
LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep systems up and running at optimal levels. It facilitates fast and easy installation and set-up, minimizes system downtime, and eliminates unnecessary service calls, which helps reduce the Total Cost of Ownership (TCO) – as well as creates a new source of Recurring Monthly Revenue (RMR).

Features:

  • UL is Listed in the U.S. and Canada.
  • Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
  • Monitor real-time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.
  • Access control and user management: Restrict read/write, Restrict users to specific resources
  • Two (2) integral network controlled Form “C” Relays.
  • Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
  • Email and Windows Dashboard notifications
  • The event log tracks history.
  • Secure Socket Layer (SSL).
  • Programmable via USB or web browser – includes operating software and 6 ft. USB cable.

LINQ2 Mounts Inside any Trove Enclosure

Enclosure Dimensions  (H x W x D approximate):
18” x 14.5” x 4.625” (457mm x 368mm x 118mm)

Hartmann Controls is not responsible for any typographical errors.
10 Lockhart Rd, Barrie, ON L4N 9G8, Canada | phone: 1-877-411-0101
web site: www.hartmann-controls.com | e-mail: sales@hartmann-controls.com | Made in the U.S.A.
IITHC1 Kit Series F11U

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals