NOYAFA NF-8209 Network Cable Tester User Manual
- June 16, 2024
- NOYAFA
Table of Contents
NOYAFA NF-8209 Network Cable Tester
Please read the manual carefully before operating this unit.
- Please do not place the device in a location that is dusty, humid, or hot (above 40° C).
- Please use a battery that meets the specifications, other wise the device may be damaged.
- Please do not disassemble the device. Repair and maintenance should be done by a professional staff.
- When not using the device for a long time, please remove the battery inside the test terminal to prevent the battery liquid from leaking out.
- Please do not use this device to detective power lines (such as 220V power supply lines), the device may be damaged and personal safety may be influenced.
- Please do not perform related operations on the communication line during thunderstorms to prevent lightning strikes and personal safety.
Overview
NF-8209 is a new generation to offer digital and analog signaling all in one
network toner and probe.
It has three modes for options to track cable like digital mode, analog mode
and PoE mode. That means it’s equipped with the most powerful cable location
technologies for any work environment.
Also, it includes cable length measurement , cable faults testing, PoE
testing, Port Flash and NCV function, all these makes it a must-tool for
cabling engineers.
Keypad display and features
Product Operation
Turn on the device and enter the below main Menu
- CONT– Test open, short, cross, ect for STP, UTP cable.
- Length–measure length of Ian cable, range is 2.5m-200m.
- Scan–Analog/Digital/ PoE mode to locate Ian cables.
- PoE– available for standard or non-standard PoE switch (5-60V), identify AT or AF standard of PSE type.
- Flash–locate network port by the flashing port light on switch/ router.
- Setting-Set Language, backlight time, auto-off time, contrast and version.
Continuity testing
Connect one end of cable to “CONT” port of transmitter on the left side, the
other end to the RJ45 port of remote, Press “OK” to start testing.
If the cable is a good one, the result will be as below.
Possible results
Only if a cable exists short circuit, no matter it exists cross, breakage or not. the testing result will only display “Short” information. If it doesn’t exist short circuit, then it would display what actually it is.
Cable Open
If the LCD screen display “Cable Open!”, there are several reasons for this.
- All the pins are open indeed.
- No cable is connected.
- The remote is not connected.
- Connect with wrong port.
Length measurement
Connect one end of cable to “Length/Port flash” port, disconnect the cable at far end, choose “Length” on the main menu, and select the preferred unit (meter/ yard/ feet ) before testing. then press start to measure and the result will come out soon on the screen.
From the image, it means there exsits problem at 12 .1 m. To make sure it is
short or broke there, you can test its continuity to know details.
Kind reminds when measuring cable length.
- The Ian cable to be tested must be de-energized.
- Disconnect the cable at the far end, no remote, no other devices connected!
- The range must be 2.5m-200m, otherwise, it would be display O meter.
- When measuring broken cables, if the broken point is too close to the empty end (less than 3% of the full length), due to technical reason, the device will show the full length of the cable, in that case customers were suggested to measure the length from the other end to locate the broken point.
Cable scan
Connect the cable to be tested to “SCAN” port of transmitter on the left side, enter “SCAN” on the main menu, press ok to choose scan mode you prefer, the default is digital mode, the other modes is Analog & PoE. then set the corresponding mode on receiver accordingly. After that, hold the receiver to locate cable at the other end, the loudest voice is the correct one.
Attention : If the tranmistter is in PoE scan and digital scan mode, the
receiver must be in digital mode. the analog scan in transmitter matches
analog mode in receiver. If the modes are not matched correctly, even the
receiver touch the correct cable, it won’t generate tone, either.
Non-contact voltage detecting: press the “Power/Set” button on the
receiver, if the “NCV” indicator is lit on, then you can use the receiver to
detect AC voltage presence.
PoE Testing
Standard PoE device
It can test the information of standard PoE device, such as POE voltage, power
supply polarity, power supply mode and also the type of PSE(if or at
standard). Connect the cable into “PoE” port, the testing result display as
below image.
Non-standard PoE device
If the PoE device is non-standard, it can also test POE voltage, power supply
polarity, power supply mode, but it can’t tell the type of PSE, just display
“Non standard”. Connect the cable into “PoE” port, the testing result display
as below image.
Attention: If all the 8 pins are providing power, it won’t display
polarity.
If connected with PoE device, the result can be displayed after a few secs, it
there is no result displayed after 30secs, then the device connected may not
be PoE device.
Port Flash & Switch details testing
- Connect a Ian cable to “Length/Flash” port on the main unit, choose “Flash” on the main menu to start testing. The 2 indicators on the “Length / Flash” port will be lit and flash.
- Then observe the ports on switch, if there is a port whose flash frequency is 3 secs, and slower than all the other ports, it tells you the port is the target one you’re looking for.
- Also, the device can tell you the connected switch’s information, such as its speed (1 0M/1 00M/1 000M), transmitting modes (FOX: full duplex / HDX: half duplex) Protocol (Auto-Nego / Non-AutoNego ). See the graph for ref. as below.
Setting
Backlight setting
Adjust the backlight time among 15s, 30s, 60s, on, and off.
Auto-off time
adjust the backlight time among 15mins, 30mins, 1 h, OFF.
Contrast setting
Press the left and right keys to adjust the contrast to suit yourself.
Version information
To check version information of software and hardware.
Specification
EMITTER | Wireman | Cable type | CAT5e, CAT6, CAT6a (STP & UTP) |
---|---|---|---|
Test with switch directly | Yes | ||
Max range | 600m | ||
Length | Cable type | CAT5e, CAT6, CAT6a (STP & UTP) |
- Test range
- Accuracy
|
- 2.5~ 200m
- ±1.6m
Breakage location| Yes
Scan| Cable type| CAT5e, CAT6, CAT6a (STP & UTP)
Max. signal voltage| 9±1Vp-p
Frequency| 130KHz
Analog/Digital mode| Yes
Max range| 600m
POE| Test range| DC5~60V standard/ non-standard PoE switch
Voltage display| Yes
PSE type| Standard : IEEE 802. 3af/at; Non standard
EMITTER| LCD display| 128″64 Dot-matrix with backlight
---|---|---
Power supply| AAA battary”3 (Not included)
Low battary warning| 2. 7V
- Auto-of f time
- Voltage protection
| 15min/ 30min/ 60min/ OFF DC4 8V5mA
Max working current| <150mA
Size| 130″70″28mm
RECEIVER| Sentivity adjustable| Yes
AC Voltage detecting| Yes
Lamp| Yes
Baltary type| 9V”1pc (Not included)
Low battary warning| 6± 0.5V
Max working current| <100mA
Size| 210″4 3″27mm
REMOTE| Wireman Port| RJ45
Voltage protection| DC4 8V5mA
Size| 65″37″23mm
Accessories
Emitter | 1pc | Carry bag | 1pc |
---|---|---|---|
Receiver | 1pc | Cable adaptor | 1pc |
Remote | 1pc | Certification | 1pc |
User manual | 1pc |
FAQ
Result | Reason or solution |
---|---|
Different testing results for one same cable | Check whether the cable |
ends are connected well
Keeps the ports clean
Length measured 0.0m| Connects to wrong port, “Length/Flash” is the
correct one.
Make sure the tested cable length is 2.5m-200m
**No results display when test PoE| Connects to wrong port , “
PoE ” is the correct one
Test the cable’s continuity to make sure it is a good cable
Check the PoE device is power on
** No flashing port when use port flash| Connects to wrong port,
“Length/Flash” is the correct one
Test the cable’s continuity to make sure it is a good cable
Check the router or switch is on
No tone when track cable| Connects to wrong port, “SCAN” is the correct
one
The mode of transmitter and receiver must keep the same
Check whether the battery is low
Turn up the sensitivity
The text on screen is blurry| Adjust the contrast to suit yourself
Turn on the device and auto off soon| **** Replace a new battery
Diagram of Series Products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>