Schneider Electric A9XPK707 VDIS Vertical Distribution Blocks Installation Guide
- June 16, 2024
- Schneider Electric
Table of Contents
Schneider Electric A9XPK707 VDIS Vertical Distribution Blocks
Linergy
Acti9 VDIS vertical distribution blocks 125 A / 160 A
Tools required
PLEASE NOTE
- The installation, maintenance and eventual replacement of this device must only be carried out by a qualified electrician.
- This device must not be repaired.
- All applicable local, regional and national regulations must be complied with during the installation, use, maintenance and replacement of this device.
- This device should not be installed if, when unpacking it, you observe that it is damaged.
- Schneider Electric cannot be held responsible in the event of noncompliance with the instructions in this document and in the documents to which it refers.
- The service instruction must be observed throughout the life time of this device.
A9XPKV04
Support for installation into PrismaSeT G and Prisma Pack enclosure.
A9XPKL10
Spare part: Locking Clip for installation into PrismaSeT XS 24 – PrismaSeT S 24 – Resi9 24 – Pragma 24 modules enclosure.
Mounting
PrismaSeT G – Prisma Pack
PrismaSeT XS 24 – PrismaSeT S 24 – Resi9 24 – Pragma 24
Selection Guide: PrismaSeT XS 24 – PrismaSeT S 24 and Resi9
- Pragma 24 surface mounted modules enclosures
Rows
1 -2 – 3 | 4 – 5 | 6 | 7 – 8 |
---|
PrismaSeT XS 24
A9XPK707| –| | | –
A9XPK714| –| –| | –
A9XPK715| –| –| –| –
PrismaSeT S 24
A9XPK707| –| | |
A9XPK714| –| –| |
A9XPK715| –| –| |
PrismaSeT XS 24 – PrismaSeT S 24 – Resi9 24 – Pragma 24
PrismaSeT S 24
Wiring
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
- This equipment must only be installed by a qualified person. This operation must only be carried out after reading all the instructions in this document.
- NEVER work alone.
- Before making the visual inspections, tests or maintenance operations on this equipment, disconnect all electrical power supplies.
- Start off with the principle that all circuits are live until they have been completely powered down, tested and labeled. Pay special attention to the design of the power supply circuit. Take account of all power supply sources, including the possibility of feedback.
- Wear suitable personal protective equipment and respect applicable electrical safety instructions.
- Use a Voltage Tester of the appropriate rating.
Failure to follow these instructions will result in death or serious injury
|
18 mm
|
18 mm
|
18 mm
---|---|---|---
A9XPK707
A9XPK714
|
10… 35 mm²
|
10… 35 mm²
|
10… 35 mm²
A9XPK715
|
|
18 mm
|
18 mm
|
18 mm
|
18 mm
---|---|---|---|---
A9XPK707
A9XPK714
A9XPK715
|
1.5…10 mm²
|
4…16 mm²
|
1.5…16 mm²
|
1.5…16 mm²
Dismounting
PrismaSeT G – Prisma Pack
PrismaSeT XS 24 – PrismaSeT S 24 – Resi9 24 – Pragma 24
Annexe
NSXm
NSX – NSXm
Danger
Installation by electricians only
Wear cut- resistant gloves
Customer Support
Schneider Electric Industries SAS
35, rue Joseph Monier
CS 30323
F – 92506 Rueil Malmaison Cedex
Schneider Electric Limited
Stafford Park 5
Telford, TF3 3BL
United Kingdom
© 2023 Schneider Electric – All rights reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>