XMP550 Quick Start Guide – FW.2.4.25
This quick start guide is based on firmware version 2.4.25. Please visit https://flandersscientific.com/firmware/ if you would like to check for potential firmware updates.
The full user manual can be found at https://flandersscientific.com/support/manuals.php
Color System
Your monitor has arrived fully calibrated. Please leave the Color System
option found in the Color menu set to GaiaColor to access the calibrated
positions. The None option disables calibration and the 3rd Party option is an
empty and uncalibrated set of memory slots available for use with 3rd party
applications.
Within the GaiaColor Color System you will find all the available Gamut, EOTF,
Correlated Color Temperature, and Luminance options supported by the monitor.
Any selection made within the GaiaColor mode activates a calibrated monitor
state instantaneously, without having to re-profile the display, based on the
last direct connect volumetric AutoCal profile data saved to the monitor’s
non-volatile memory.
Connectivity
The preferred configuration is single link 12Gbps or 6Gbps SDI. Quad Link
3Gbps and 1.5Gbps Square Division signals are also supported, but must be
manually selected from the Video Menu.
FW 2.4.25 Known Issues List
We are aware of the nuisance items below and are working on addressing them in
future releases, but if you note any issues / bugs not listed here please
report them to
XMP550@FlandersScientific.com
Panel Dimming -> ON is currently disabled. The monitor only works in the
reference Panel Dimming -> OFF mode at present. Panel dimming will be enabled
as an optional toggle in a future release.
3rd Party Color System currently only works in Normal LUT Mode. Advanced LUT
Mode is not currently support- ed in 3rd Party mode. This has no impact on
default GaiaColor Color System operation.
Embedded Audio is distorted with 4:2:2 sources. Using 4:4:4 will avoid
distortions on speakers / line out.