PHILIPS BVP158 LED Floodlight Instruction Manual

June 16, 2024
Philips

PHILIPS-LOGO

PHILIPS BVP158 LED Floodlight

PHILIPS-BVP158-LED-Floodlight-FIG-1

PRODUCT INFORMATION

Specifications

  • Product Type: LED Floodlight
  • CCT (Correlated Color Temperature):
    • WW (Warm White): 3000K
    • NW (Neutral White): 4200K
    • CW (Cool White): 6500K
  • Power(W):
    • *BVP158 LED12/WW_NW_CW PSU 10W SWB CN 4200:** 10W
    • *BVP158 LED24/WW_NW_CW PSU 20W SWB CN 4200:** 20W
    • *BVP158 LED36/WW_NW_CW PSU 30W SWB CN 4200:** 30W
    • *BVP158 LED60/WW_NW_CW PSU 50W SWB CN 4200:** 50W
    • *BVP158 LED84/WW_NW_CW PSU 70W SWB CN 4200:** 70W
    • *BVP158 LED120/WW_NW_CW PSU 100W SWB CN 4200:** 100W
    • *BVP158 LED180/WW_NW_CW PSU 150W SWB CN 4200:** 150W
    • *BVP158 LED240/WW_NW_CW PSU 200W SWB CN 4200:** 200W
  • Lumen Output (lm):
    • 3000: 1100, 1200, 2200, 2400, 3300, 3600
    • 4200: 5500, 6000, 7700, 8400
    • 6500: 11000, 12000, 16500, 18000, 22000, 24000
  • Dimension(mm):
    • AxBxCxD(mm):
    • 10W/20W/30W/50W without buckle: 70x130x31x90
    • 70W/100W/150W/200W with buckle: 82x149x31x109, 117x182x29x145, 150x232x30x185, 175x284x33x215, 185x312x36x244, 242x409x37x320, 296x482x39x380
  • Voltage: 220-240V~
  • Frequency: 50/60Hz
  • Surge rating: 2KV/2KV (10W-50W), 4KV/4KV (70W-200W)
  • IP Rating: IP65

Product Usage Instructions

Mounting Instructions

  1. Install the luminaire according to the national regulation and make sure it will not fall off.
  2. Fasten the bolt with the specified torque:
    • 10W: 2 Nm
    • 20W: 2 Nm
    • 30W: 2 Nm
    • 50W: 8 Nm
    • 70W: 8 Nm
    • 100W: 15 Nm
    • 150W: 25 Nm
    • 200W: 25 Nm

FAQ

  1. What is the IP rating of the LED Floodlight?
    The IP rating of the LED Floodlight is IP65.

  2. What are the available power options for the LED Floodlight?
    The available power options for the LED Floodlight are:

    1. 10W
  3. 20W

  4. 30W

  5. 50W

  6. 70W

  7. 100W

  8. 150W

  9. 200W

  10. What are the CCT (Correlated Color Temperature) options for the LED Floodlight?
    The CCT options for the LED Floodlight are:

    1. WW (Warm White): 3000K
  11. NW (Neutral White): 4200K

  12. CW (Cool White): 6500K

  13. What is the voltage and frequency supported by the LED Floodlight?
    The LED Floodlight supports a voltage of 220-240V~ and a frequency of 50/60Hz.

  14. What is the surge rating of the LED Floodlight?
    The surge rating of the LED Floodlight is 2KV/2KV (10W-50W) and 4KV/4KV (70W-200W).

  15. What is the maximum number of luminaires that can be connected to an MCB 16A Type B?
    The maximum number of luminaires that can be connected to an MCB 16A Type B are:

    1. 10W: 218 pcs
  16. 20W: 109 pcs

  17. 30W: 73 pcs

  18. 50W: 44 pcs

  19. 70W: 31 pcs

  20. 100W: 22 pcs

  21. 150W: 15 pcs

  22. 200W: 11 pcs

  23. What is the maximum number of luminaires that can be connected to an MCB 16A Type C?
    The maximum number of luminaires that can be connected to an MCB 16A Type C are:

    1. 10W: 254 pcs
  24. 20W: 127 pcs

  25. 30W: 85 pcs

  26. 50W: 51 pcs

  27. 70W: 36 pcs

  28. 100W: 25 pcs

  29. 150W: 17 pcs

  30. 200W: 13 pcs

PRODUCT SPECIFICATION

PHILIPS-BVP158-LED-Floodlight-FIG-2

DIMENSION

PHILIPS-BVP158-LED-Floodlight-FIG-3
PHILIPS-BVP158-LED-Floodlight-FIG-4

WIRE CONNECTION

PHILIPS-BVP158-LED-Floodlight-FIG-5

  • Always use min IP65 or higher IP rated junction box/ connector for direct wiring connection with luminaire.

  • The Luminaire should never be used in submerged wet conditions e.g. under water,soil,snow etc.

  • The wiring connection should also never be used in submerged wet conditions e.g.water,soil,snow etc.
    OR
    use IP68 junction box.

  • The warranty is void, in case any of the instructions / guidelines are not followed as per given mounting instruction.

  • This product is not supplied with any junction box / connector.

  • For further clarification, please contact the manufacturer

ROTATING CAPACITY

Install the luminaire according to the national regulation and make sure it will not fall off.

PHILIPS-BVP158-LED-Floodlight-FIG-6
PHILIPS-BVP158-LED-Floodlight-FIG-7

INPUT/OUTPUT

PHILIPS-BVP158-LED-Floodlight-FIG-9

leakage current

PHILIPS-BVP158-LED-Floodlight-FIG-9

The leakage current *(touch current or protective conductor current) of electrical circuit may be greatly dependent upon electrical supply cables used such as its rating and length, proper connection of electrical supply cables to luminaires and wiring connection topology of luminaires to the supply electrical circuit amongst other site conditions.

  • In some cases referred to as Earth Leakage Current.

Please read this manual carefully before using the product.

  • Do not switch on before complete installation.
  • The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
  • The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.
  • The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
  • The luminaire is complied with IEC60598 or GB7000.
  • Luminaire must not be used or stored in corrosive environment where hazardous materials such as Sulphur, Chlorine, phthalates, etc,are present.