Danger! – Read the operating instructions to reduce the risk of inquiry

Danger!
When using the equipment, a few safety precautions must be observed to avoid injuries and damage. Please read the complete operating instructions and safety regulatioith due care. Keep this manual in a safe place, so that the information is available at all times. If you give the equipment to any other person, hand over these opera instructions and safety regulations as well. We cannot accept any liability for damage or accidents which arise due to a failure to follow these instructions and the safety instructions.

Safety regulations

Danger!
Read all safety regulations and instructions.
Any errors made in following the safety regulations and instructions may result in an electric shock, fi re and/or serious injury.
Keep all safety regulations and instructions in a safe place for future use.

Danger!
The equipment is not designed for use in swimming pools and paddling pools of any kind or other bodies of water in which people or animals may be present during operation. It is prohibited to operate the equipment if a person or animal is in the danger area. Ask your electrician!

  • The equipment must always be disconnected from the mains supply before it is assembled, taken apart or cleaned.
  • The equipment can be used by people with limited physical, sensory or mental capacities or by persons with restricted experience and restricted knowledge if they are supervised or have received instruction in how to use the equipment safely and understand the dangers which result from such use.
  • Children are not allowed to play with the equipment
  • If pumps are not accompanied by information confirming that they are protected from freezing, they are not allowed to be left outdoors in frosty weather.
  • The equipment is not allowed to be used when there are people in the water.
  • The equipment is allowed to be used only with an earth-leakage circuit breaker (RCD) with a rated fault current of no more than 30 mA.
  • Before you put the equipment into operation, arrange for a specialist to check that the earthing, protective multiple earthing or residual-current operated circuit-breaker circuit comply with the safety regulations of the power supply company and work correctly.
  • The electrical plug-in connections must be protected from wet conditions.
  • If there is a risk of flooding, place the plug-in connections in an area which is safe from flooding.
  • Strictly avoid pumping aggressive liquids and abrasive substances.
  • Protect the equipment from frost.
  • Protect the equipment from dry running.
  • Take suitable measures to keep the equipment out of the reach of children.

Layout and items supplied

Layout (Fig. 1)

  1. Pressure connector
  2. Suspension eyelets
  3. Dirt screen
  4. Securing cable

Items supplied
Please check that the article is complete as specific edh in the scope of delivery. If parts are missing, please contact our service center or he sales outlet where you made your purchase at the latest within 5 working days after purchasing the product and upon presentation of a valid bill of purchase. Also, refer to the warranty table in the service information at the end of the operating instructions.

  • Open the packaging and take out the equipment with care.
  • Remove the packaging material and any packaging and/or transportation braces (if available).
  • Check to see if all items are supplied.
  • Inspect the equipment and accessories for transport damage.
  • If possible, please keep the packaging until the end of the guarantee period.

Danger!
The equipment and packaging material are not toys. Do not let children play with plastic bags, foils or small parts. There is a danger of swallowing or scuff coating!

  • Deep well pump
  • Securing cable
  • Original operating instructions

Proper use

The equipment you have purchased is designed to pump water with a maximum temperature of 35 °C. This equipment must never be used for other liquids, especially not for engine fuels, cleaning agents and other chemically-based products!

The equipment can be used wherever you want to move water, e.g. in the house, in the garden, and for many other applications. It must not be used to operatewimming pools!

If you want to use the equipment in bodies of water with a natural, muddy bottom, place the equipment in a slightly elevated position, e.g. on bricks.

The equipment is not designed for continuous operation, e.g. as a circulating pump in a pond. In this case the equipment’s anticipated life will be greatly shortened because the equipment was not designed for continuous loading.

The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user / operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.

Please note that our equipment has not been designed for use in commercial, trade or industrial applications. Our warranty will be voided if the machine is used immercial, trade or industrial businesses or for equivalent purposes.

The water may be contaminated by escaping lubricating oil/lubricant.

Technical data

Rated voltage/frequency ……220-240 V~ 50 Hz
Power rating ………1000 W
Max. pumping rate …………6500 l/h
Max. delivery head …………45 m
Max. submersion depth …………19 m
Max. water temperature ………..35 °C
Hose connection …………. approx. 42 mm (11/4“) IG
Max. size of foreign bodies : ………..clear water
Protection type. ………IPX8
Power cable …….22 m

Before starting the equipment

Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.

Installation
The equipment can be installed either:

  • Stationary with a rigid pipe line
    or

  • Stationary with a flexible hose line

  • Connect the pressure hose or pipe to the pressure connector (1) using a suitable connector.

  • Fasten the securing cable (4) to the suspension eyelet (Fig. 1/Item 2).

Notice!
Before you use the pump, clarify any possible special conditions which need to be fulfil lled for the installation!
For example, additional safety measures may be needed if damage to property could result from a power failure, soiling or a defective gasket
Examples of such safety measures:
Pumps running in parallel on a separately protected power circuit, moisture sensors for switching off the pumps, and similar safety arrangements.
Be sure to consult a professional plumber if you have any doubt.

If you use rigid pipe lines, we recommend that you use cable ties to bind the power cable to the discharge line, with a spacing of approx. 3 m.

Install the pump in such a way that the underside is at least 20 cm above the bottom, in order to prevent sand, sludge, etc., being drawn into the pump.

When installing, never hang the equipment by the discharge line or by the power cable. The device must be hung up by the provided suspension eyelets.

The pump shaft should be large enough.

Mains connection
Danger!
The equipment you have purchased comes with an earthing-pin plug. The equipment is designed for connection to a socket outlet with earthing contact for 220-240 V~ 50 Hz. Make sure that the socket outlet is suffix cogently fused (at least 6 A) and in good working order. Insert the power plug in the socket-outlet and the equipment is ready for operation.

Danger!
To rule out danger, this work must be left strictly to a specialist electrician orustomer Service.

Operation

You can put the equipment into operation after you have thoroughly read the installation and operating instructions. Pay attention to the following points:

  • Check that the discharge line is fitted correctly.
  • Make sure that the electrical connection is 220-240 V~ 50 Hz.
  • Check that the electrical socket-outlet is in good working order.
  • Make sure that no moisture or water can ever reach the power connection.
  • Lower the pump into the well or shaft using the securing cable.
  • Ensure that the pump is completely under the surface of the water and approx. 20 cm above the bottom.
  • Make sure that the equipment does not run dry.
  • To switch off the equipment, pull the power plug out of the socket

Replacing the power cable

Danger!
If the power cable for this equipment is damaged, it must be replaced by tnufacturer or its after-sales service or similarly trained personnel to avoid danger

Cleaning, maintenance and ordering of spare parts

Danger!

  • Unplug the power plug prior to any maintenance work.
  • For mobile applications, the equipment should be cleaned with clear water after every usage.
  • Undo the fastening screws on the dirt screen (Figure 1/Item 3) and clean the dirt screen and intake section.
  • Insert the dirt screen again.

Maintenance
There are no parts inside the equipment which require additional maintenance.

Ordering replacement parts:
Please quote the following data when ordering replacement parts:

  • Type of machine
  • Article number of the machine
  • Identification number of the machine
  • Replacement part number of the part required

Current prices and information are available on request at your Hornbeck store

Storage

Store the equipment and accessories in a dark and dry place at above freezing temperature. The ideal storage temperature is between 5 and 30 °C. Store the electric tool in its original packaging.

  • If the pump is not going to be used for a long time or has to be removed for the winter months, rinse it out with water, empty it completely and allow it to dry.
  • The equipment must be completely drained before it is subjected to frost.

Troubleshooting guide

Faults Cause Remedy

The equipment does
not start|

  • -Power supply not connected

|

  • Check power supply

The equipment does
not pump|

  • Intake sieve clogged –
  • Discharge hose kinked

|

  •  Clean intake sieve with water jet
  • Unkink the hose

Insafe client
pumping rate|

  • -Intake sieve clogged –
  • Performance reduced due to heavily contaminated and abrasive water impurities

|

  • Clean intake sieve
  • Clean equipment and replace wear parts

The equipment switches off after
briefly y running|

  • -Motor circuit-breaker switches the equipment off due to excessive water contamination
  • Water temperature too high; motor circuit breaker switches the equipment of

|

  •  Unplug power plug and clean equipment ands haft-
  • Ensure that maximum permissible water temperature (35 °C) is notexceeded

Declaration of Conformity

We declare, that the product described in Technical Data

Deep well pump PE-TP 1000 N

Manufactured for:

Hornbeck Baumert AG
Hornbachstraße 11
76879 Bornholm / Germany

is in conformity with the following directives:

Machinery Directive 2006/42/EC
EMC Directive 2014/30/EG
RoHS Directive 2011/65/EG

and in accordance to the following applicable harmonized standards:

EN 60335-1:2012+A11+A13+A1+A14+A2+A15
EN IEC 60335-2-41:2021+A11
EN 62233: 2008
EN ISO 12100:2010
EN IEC 55014-1:2017+A11
EN IEC 55014-2:2015
EN IEC 61000-3-2:2019
EN 61000-3-3:2013+A1

Andreas Back
Head of Quality Management &
Person authorised to compile the technical file

Bornholm, 12.04.2023

Hornbeck Baumert AG
Hornbachstraße 11
76879 Bornholm / Germany

Disposal

The crossed-out wheeled bin logo requires the separate collection of waste electric and electronic equipment (WEEE). Such equipment may contain dangerous and hazardous substances. These tools must be returned to a designated collection point for the recycling of WEEE and must not be disposed as unsorted municipal waste. By doing so, you will help to conserve resources and protect the environment

HORNBACH is committed in Germany:

  • when purchasing a new electrical or electronic device, to take back an old device of the same type free of charge at a
    HORNBACH store.

  • You can take back up to 3 old electrical or electronic devices of the same type (up to a maximum edge length of 25 cm) free of charge at a HORNBACH store, even without buying a new one.

  • When delivering a new electrical or electronic device to a private household, to pick up an old device of the same type free of charge or to enable you to return it in your immediate vicinity