Danfoss VACON 100 X Motor Mountable AC Drives User Guide
- June 16, 2024
- Danfoss
Table of Contents
Danfoss VACON 100 X Motor Mountable AC Drives
Product Information
Specifications
- Minimum distance around the inverter: All types – 80mm
- Motor terminals: U/T1, V/T2, W/T3
- DC bus terminals: DC+, DC-
- Brake resistance terminals: R+, R-
- Earth conductor
Product Usage Instructions
Changing the Control Place
To change the control place, follow these steps:
- Modify the source of command
- Select ‘Local/Remote’ or ‘Local’ or ‘Remote’
- If ‘Local/Remote’ is selected, press ‘OK’
- If ‘Local’ or ‘Remote’ is selected, press ‘OK’
- If ‘Local/Distance’ is selected, press ‘OK’
The Graphical Display (A)
- The location field
- An activated group or item
- The number of items in the group in question
- The first status field: STOP/RUN
- The rotation direction
- The second status field: READY/NOT READY/FAULT
- The alarm field
- The control place
The Text Display (B):
- The indicators of status
- The indicators of alarm and fault
- The name of the group or item
- The current location in the menu
- The indicators of the rotation direction
- The indicators of the control place
The Buttons of the Keypad (C)
- BACK/RESET button
- OK button
- Arrow button UP
- FUNCT button
- Arrow button RIGHT
- START button
- Arrow button DOWN
- 22 – STOP button
- 23 – Arrow button LEFT
Frequently Asked Questions (FAQ):
-
Q: What is the minimum distance required around the inverter?
A: The minimum distance required around the inverter is 80mm for all types. -
Q: What are the motor terminals?
A: The motor terminals are U/T1, V/T2, and W/T3. -
Q: What are the DC bus terminals?
A: The DC bus terminals are DC+ and DC-. -
Q: What are the brake resistance terminals used for?
A: The brake resistance terminals are used for connecting a brake resistor. -
Q: What is the purpose of the earth conductor?
A: The earth conductor is used for grounding.
Download and read Vacon 100 X Installation Manual at: http://drives.danfoss.com/knowledge-center/techni-cal-documentation/
CABLE INSTALLATION
- L1 Mains
- U/T1 Motor
- DC+ DC bus terminals
- DC- Borne de bus DC
- R+ Brake resistor terminals
- R-
- The earth conductor
COOLING
The minimum clearance (mm) around the drive
CONTROL PANEL AND KEYPAD
FUNCT (18)
Use it to change the rotation direction of the motor, access the control page,
and change the control place.
- Changing the control place:
- ‘Local/Remote’ 3.
- . ‘Local’ or ‘Remote’ 5.
CONTROL TERMINALS
- Control terminals 1-30
- Relay terminals Bornes relais
- Thermistor input
- Option boards
- STO Terminals
- Ethernet Terminal Borne Ethernet
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>