Danfoss VACON 100 X Motor Mountable AC Drives User Guide

June 16, 2024
Danfoss

Danfoss VACON 100 X Motor Mountable AC Drives

Danfoss-VACON-100-X-Motor-Mountable-AC-Drives-product

Product Information

Specifications

  • Minimum distance around the inverter: All types – 80mm
  • Motor terminals: U/T1, V/T2, W/T3
  • DC bus terminals: DC+, DC-
  • Brake resistance terminals: R+, R-
  • Earth conductor

Product Usage Instructions

Changing the Control Place
To change the control place, follow these steps:

  1. Modify the source of command
  2. Select ‘Local/Remote’ or ‘Local’ or ‘Remote’
  3. If ‘Local/Remote’ is selected, press ‘OK’
  4. If ‘Local’ or ‘Remote’ is selected, press ‘OK’
  5. If ‘Local/Distance’ is selected, press ‘OK’

The Graphical Display (A)

  • The location field
  • An activated group or item
  • The number of items in the group in question
  • The first status field: STOP/RUN
  • The rotation direction
  • The second status field: READY/NOT READY/FAULT
  • The alarm field
  • The control place

The Text Display (B):

  • The indicators of status
  • The indicators of alarm and fault
  • The name of the group or item
  • The current location in the menu
  • The indicators of the rotation direction
  • The indicators of the control place

The Buttons of the Keypad (C)

  • BACK/RESET button
  • OK button
  • Arrow button UP
  • FUNCT button
  • Arrow button RIGHT
  • START button
  • Arrow button DOWN
  • 22 – STOP button
  • 23 – Arrow button LEFT

Frequently Asked Questions (FAQ):

  • Q: What is the minimum distance required around the inverter?
    A: The minimum distance required around the inverter is 80mm for all types.

  • Q: What are the motor terminals?
    A: The motor terminals are U/T1, V/T2, and W/T3.

  • Q: What are the DC bus terminals?
    A: The DC bus terminals are DC+ and DC-.

  • Q: What are the brake resistance terminals used for?
    A: The brake resistance terminals are used for connecting a brake resistor.

  • Q: What is the purpose of the earth conductor?
    A: The earth conductor is used for grounding.

Download and read Vacon 100 X Installation Manual at: http://drives.danfoss.com/knowledge-center/techni-cal-documentation/

CABLE INSTALLATION

  • L1 Mains
  • U/T1 Motor
  • DC+ DC bus terminals
  • DC- Borne de bus DC
  • R+ Brake resistor terminals
  • R-
  • The earth conductor

Danfoss-VACON-100-X-Motor-Mountable-AC-Drives- \(2\)

COOLING

Danfoss-VACON-100-X-Motor-Mountable-AC-Drives- \(1\)

The minimum clearance (mm) around the drive

CONTROL PANEL AND KEYPAD

Danfoss-VACON-100-X-Motor-Mountable-AC-Drives- \(4\)

FUNCT (18)
Use it to change the rotation direction of the motor, access the control page, and change the control place.

  • Changing the control place:
  • ‘Local/Remote’ 3.
  • . ‘Local’ or ‘Remote’ 5.

Danfoss-VACON-100-X-Motor-Mountable-AC-Drives- 02

CONTROL TERMINALS

Danfoss-VACON-100-X-Motor-Mountable-AC-Drives- \(8\) Danfoss-VACON-100-X-Motor-Mountable-AC-Drives-
\(8\)

  1. Control terminals 1-30
  2. Relay terminals Bornes relais
  3. Thermistor input
  4. Option boards
  5. STO Terminals
  6. Ethernet Terminal Borne Ethernet
    Danfoss-VACON-100-X-Motor-Mountable-AC-Drives- \(11\)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals