Solenoid interlock AZM 161CC-12/12RKT-024
About this document
1.1 Function
This document provides all the information you need for the mounting, set-up
and commissioning to ensure the safe operation and disassembly of the
switchgear. The operating instructions enclosed with the device must always be
kept in a legible condition and accessible.
1.2 Target group of the operating instructions: authorised qualified
personnel
All operations described in the operating instructions manual must be carried
out by trained specialist personnel, authorised by the plant operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and putting
the component into operation.
The machine builder must carefully select the harmonised standards to be
complied with as well as other technical specifications for the selection,
mounting and integration of the components.
The information contained in this operating instructions manual is provided
without liability and is subject to technical modifications.
1.3 Explanation of the symbols used
Information, hint, note: This symbol is used for identifying useful
additional information.
Caution: Failure to comply with this warning notice could lead to failures
or malfunctions.
Warning: Failure to comply with this warning notice could lead to
physical injury and/or damage to the machine.
1.4 Appropriate use
The Schmersal range of products is not intended for private consumers.
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It is
the responsibility of the manufacturer of a machine or plant to ensure the
correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with the versions
listed below or for the applications authorised by the manufacturer. Detailed
information regarding the range of applications can be found in the chapter
“Product description”.
1.5 General safety instructions
The user must observe the safety instructions in this operating instructions
manual, the country specific installation standards as well as all prevailing
safety regulations and accident prevention rules.
Product description
2.1 Ordering code
AZM161 (1)-(2)(3)K(4)-(5)/(6)-(7)(8)
(1)
SK| Bolted
CC| cage clamp
(2)
3-Nov| 1 normally open contact / 4 normally closed contacts (connector
version)
3-Dec| 1 normally open contact / 5 normally closed contacts
11-Dec| 2 NO contacts / 3 NC contacts (connector version)
12-Nov| 2 normally open contacts / 4 normally closed contacts
(3)
none| Fastening force 5N
R| Fastening force 30N
(4)
none| Power on to unlock
A| Power on and lock
(5)
none| Lateral manual unlocking
ED| Manual unlocking of cover
(6)
T| Side emergency exit
TD| Covered emergency exit
TU| emergency unlock
(7)
24| Us: 24 VAC/DC
110/230| Us: 110/230 VAC
(8)
G| With LED (only for Us: 24 VAC/DC)
2.2 Special versions
For special versions, which are not listed in the ordering code, these
specifications apply accordingly, provided that they correspond to the
standard version.
2.3 Purpose
The solenoid interlock has been designed to prevent in conjunction with the
control part of a machine, movable safety guards from being opened before
hazardous conditions have been eliminated.
Interlocks with power to lock principle may only be used in special
cases after a thorough evaluation of the accident risk, since the safety guard
can be opened immediately on failure of the power supply or upon activation of
the main switch.
The safety switchgears are classified according to EN ISO 14119 as type 2
interlocking devices.
The user must evaluate and design the safety chain in accordance with
the relevant standards and the required safety level.
** The entire concept of the control system, in which the safety component
is integrated, must be validated to the relevant standards.
2.4 Warning about misuse
** In case of improper use or manipulation of the safety switchgear,
personal hazards or damages to machinery or plant components cannot be
excluded. There are no residual risks, provided that the safety instructions
as well as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
2.5 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with the operating instructions
manual. The manufacturer shall accept no liability for damages resulting from
the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary repairs,
conversions and modifications to the device are strictly forbidden, the
manufacturer shall accept no liability for damages resulting from such
invasive work, arbitrary repairs, conversions and/or modifications to the
device.
2.6 Technical Data
B 10D Normally-closed contact (NC) | 2,000,000 |
---|---|
Note | Electrical life on request. |
B10D Normally-open contact (NO) | 1,000,000 |
Note | at 10% Ie and ohmic load |
Note for 2-channel use and with suitable logic unit.
Note (Performance Level)
Information for the safety classification of the guard locking function is
documented in the “Operating instructions” or in the “Operation and mounting”
instructions.
Type of the screw head Flat head screw
Mechanical data – Connection technique
Allowed type of cable solid multi-wire flexible
Magnet switch-on time | 100% |
---|---|
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 50 ms |
Note about the safety classification
– Safety classification of the interlocking function
Basically suitable up to Cat. 1 / PL c.
With 2-channel usage with fault exclusion mechanism (if a fault exclusion to
the 1-channel mechanics is authorised) and suitable logic applicable up to
Cat. 3 / PL d(Determined values can vary
depending on the application-specific parameters hop , dop and tcycle as well
as the load.)
If multiple safety components are wired in series, the Performance Level to EN
ISO 13849-1 will be reduced due to the restricted error detection under
certain circumstances.
– Safety classification of the guard locking function
If the device is used as an interlock for personal safety, a safety
classification of the guard locking function is required. When classifying the
interlock function, a distinction must be made between monitoring of the
interlock function (locking function) and controlling the unlocking function.
The following safety classification of the unlocking function is based on the
application of the principle of safety energy disconnection for the solenoid
supply.
**** The classification of the unlocking function is only valid for devices
with monitored guard locking function and in the power to unlock version (see
ordering code).
A fault exclusion for the guard locking function can be assumed by an external
safety energy disconnection. In this case, the guard locking function does not
have an effect on the failure probability of the unlock function. The safety
level of the unlock function is determined exclusively by the external safety
power shutdown.
Legend
1| Safety power shutdown
2| Solenoid interlock
3| Guard locking function
Fault exclusion with regard to wiring routing must be observed.
If for a certain application the power to unlock version of a solenoid
interlock cannot be used, for this exception an interlock with power to lock
can be used if additional safety measure need to be realised that have an
equivalent safety level.
UL notice
Use Type 4X (Indoor Use) and 12 connector fittings. Tightening torque
rating: 4.4 lb in.
Mounting
3.1 General mounting instructions
Please observe the remarks of the standards EN ISO 12100, EN ISO 14119
and EN ISO 14120.
Three mounting holes are provided for fixing the enclosure. The solenoid
interlock is double insulated. The use of an earth wire is not authorised. The
solenoid interlock must not be used as an end stop. Any mounting position. The
mounting position however must be chosen so that the ingress of dirt and
soiling in the used opening is avoided.
Unused actuator openings must be sealed with slot sealing plugs.
The actuator must be permanently fitted to the safety guards and
protected against displacement by suitable measures (tamperproof screws,
gluing, drilling of the screw heads).
3.2 Dimensions
All measurements in mm. 3.3 Manual release
(for set-up, maintenance, etc.)
Manual release is realised by turning the triangular key by 180° (M5
triangular key available as accessory), so that the locking bolt is pulled
into the unlocking position. Please ensure that jamming by external influence
on the actuator is avoided. The normal locking function is only restored after
the triangular key has been returned to its original position. After being put
into operation, the manual release must be secured by installing the plastic
cover, which is included in delivery.
Lateral manual release| Manual release on the cover side or on the rear side
(ordering suffix -ED/-EU)
---|---
|
Triangular key TK-M5 (101100887) available as accessory.
3.4 Emergency release (ordering suffix -N)
(Fitting and actuation only from outside the hazardous area)
** The emergency release should only be used in an emergency. The solenoid
interlock should be installed and/or protected so that an inadvertent opening
of the interlock by an emergency release can be prevented. The emergency
release must be clearly labelled that it should only be used in an emergency.
The label can be used that was included in the delivery.
To activate the emergency release in case of an emergency, the orange lever
must be turned to the stop in the direction marked by the arrow. In this
position, the safety guard can be opened. The lever is latched and cannot be
returned to its original position. To cancel the blocking condition, the
central mounting screw must be loosened to such extent that the lever can be
turned back into its original position. The screw must then be re-tightened.
3.5 Emergency Exit**
(Fitting and actuation only from within the hazardous area)
To activate the emergency exit of the T version in case of an emergency, the
orange lever must be turned to the stop in direction marked by the arrow. The
emergency exit function of the TD and TU versions is activated by pressing the
red pushbutton. In this position, the safety guard can be opened. The blocking
condition is cancelled by turning the lever in opposite direction or by
pulling back the pushbutton. In unlocked position, the safety guard is
protected against unintentional closing.
Lateral emergency exit (ordering suffix -T)| Emergency exit on the cover side
or on the rear side (ordering suffix -TD/-TU)
---|---
|
Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by authorised
personnel in a de-energised condition.
If the risk analysis indicates the use of a monitored interlock they are
to be connected in the safety circuit with the contacts indicated with the
symbol .
Appropriate cable glands with a suitable degree of protection are to be used.
Remove the walls of the mounting holes by inserting the cable entry. All
plastic residues must be removed from the switch compartment. Puncturing the wall of the holes with auxiliary tools (e.g.
screwdriver) can cause damage.
Settle length x of the conductor:
– on cage clamps (CC) of type s or f: 5 … 6 mm
– on screw terminals (SK): 7 mm 4.2
Contact Options
Contacts shown in a de-energised condition and with the actuator inserted.
Power to unlock | Power to lock |
---|
AZM 161SK-12/12… und AZM 161CC-12/12…
|
AZM 161SK-12/03… und AZM 161CC-12/03…
|
Key
| Positive break NC contact
| Monitoring the interlock according to EN ISO 14119
| Actuated
| Not actuated
AZM 161ST-../.. with connector
AZM 161ST-12/11…| AZM 161ST-11/12…
---|---
|
AZM 161ST-11/03…|
|
Integrated contact kit
12/12 G (with LED)The 24 V are led
internally to contacts 13 and 63. The corresponding signals of the LED display
can also be tapped at terminals 14 or 64.
Integrated contact kit 12/03 G (with LED) The 24 V are led internally to contacts 11 and 63. The
corresponding signals of the LED display can also be tapped at terminals 12 or
64.
Legend
1| Door closed
2| Solenoid on
3| Door locked
Power to unlock System condition| Magnet control Power to unlock| yellow 1|
red 2 LED| yellow 3
---|---|---|---|---
Door open| 24 V (0 V)| Off| On| Off
Door closed, actuator
inserted, not locked| 24 V| On| On| Off
Door closed, actuator
inserted and locked| 0 V| On| Off| On
Door open| 0 V (24 V)| Off| Off| Off
Door closed, actuator
inserted, not locked| 0 V| On| Off| Off
Door closed, actuator
inserted and locked| 24 V| On| On| On
Set-up and maintenance
The safety function of the safety components must be tested. In the case of correct installation and adequate use, the safety switchgear features maintenance-free functionality. A regular visual inspection and functional test, including the following steps, is recommended:
- Check fixation of the safety switch and the actuator.
- Fitting and integrity of the cable connections.
- Remove particles of dust and soiling.
Adequate measures must be taken to ensure protection against tampering
either to prevent tampering of the safety guard, for instance by means of
replacement actuators.
Damaged or defective components must be replaced.
Disassembly and disposal
6.1 Disassembly
The safety switchgear must be disassembled in a de-energised condition only.
6.2 Disposal
**** The safety switchgear must be disposed of in an appropriate manner in
accordance with the national prescriptions and legislations.
Schmersal Industrial Switch Manufacturing (Shanghai) Co., Ltd.,
No. 3336 Caoying Road, Qingpu District, Shanghai,
The details and data involved have been carefully checked.
Image may vary from original image.
You can find further technical data in the instructions.
There may be technical modifications and errors.
Generated date 2024/1/11 12:16 pm
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>