SCHMERSAL EIP Ethernet IP-Safety Fieldbox Instruction Manual

June 12, 2024
SCHMERSAL

Safety in system
Protection for man and machine
SAFETY FIELDBOX PN / EIP / EC
UNIVERSAL. SAFE.
COST EFFECTIVE.
SCHMERSAL EIP Ethernet IP-Safety Fieldbox

SAFETY FIELDBOX PN / EIP / EC

UNIVERSAL. SAFE. COST EFFECTIVE.SCHMERSAL EIP Ethernet IP-Safety
Fieldbox - Device ports

Flexible application options
The safety fieldbox allows for simple connection of up to eight safety switchgear devices with Plug and  Play. The universal device interfaces for 8-pole M12connectors allow for connection of a wide range of safety switchgear devices, including electronic and
electromechanical solenoid interlocks, sensors, control panels, light curtains and switches. The version for 8-pole connectors enables connection of 2 safety inputs, 2 test pulse outputs, 1 safety output (internal 2-channel), 1 digital input for diagnostic signals as well as the power supply to connected safety switchgear devices.
This enables transmission of locking device activation signals on solenoid interlocks, alongside safety signals  and diagnostic signals. The signals are transmittedfor evaluation to the safety controller via the safety fieldbus interface. This communication is safe against modifications, changes to the telegram sequence, transmission errors, etc. Parallel transmission of safety signals enables free evaluation of safety switchgear devices in the safety controller.SCHMERSAL EIP Ethernet IP-Safety Fieldbox -
switchgear

An additional integrated digital input on each 8-pin device portallows for evaluation of the diagnostic signals of all connectedsafety switchgear. The universal 8-pin device connection allows safety switchgear from other manufacturers to be connected with ease using, e.g. adapters.
The safety fieldbox is available with the three safety fieldbus protocols PROFINET with PROFIsafe, EtherNet/IP with CIPSafety and  EtherCAT with FSoE, in order to be able to design  the safety functions of a machine independently of the used control system.SCHMERSAL EIP Ethernet IP-Safety Fieldbox -
input

Your benefits at a glance

  • Universal 8-pole device ports
  • Smooth and fail-safe installation
  • Cost-effective machine wiring
  •  Rapid installation with Plug and Play

Technical highlights

  • 8 different safety switchgear connectable
  • 4 control panels (with EMERGENCY STOP) connectable
  • Power supply via M12 power plug connection with 10 A
  •  Fail-safe communication via the following fieldbuses:SCHMERSAL EIP Ethernet IP-Safety Fieldbox - Device connectable

SAFETY FIELDBOX PN / EIP / EC
THREE VARIANTS FOR THREE FIELD BUS SYSTEMSSCHMERSAL EIP Ethernet IP-
Safety Fieldbox - VARIANTS

Technical features

General technical data

Standards| EN 61131-1, EN 61131-2, IEC 60947-5-3, ISO 13849-1, IEC 61508
Ambient temperature| −20 °C … +55 °C
Degree of protection| IP67 / IP67
Supply voltage UB| 24 VDC –15% / +10%
Operating current Ie| 10:00 AM
Field bus interface
Integrated switch| Dual Port, 100 Mbit/s
Service interface| WEB-Interface HTTP
Safety values
2-channel safety inputs| PL e, Category 4, SIL 3
1-channel safety inputs| PL c, Category 1, SIL 1
Safety outputs 1 cable| PL d, Category 3, SIL 2
Safety outputs 2 cables| PL e, Category 4, SIL 3