SCHMERSAL 16-12ZVRK-ST Switch with Separate Actuator Instructions

June 15, 2024
SCHMERSAL

SCHMERSAL 16-12ZVRK-ST Switch with Separate Actuator Instructions

INSTRUCTIONS FOR OPERATION AND ASSEMBLY

About this document

Function

This document provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the switchgear. The operating instructions enclosed with the device must always be kept in a legible condition and accessible.

Target group of the operating instructions: authorized qualified personnel

All operations described in the operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only.

Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation.

The machine builder must carefully select the harmonized standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.

The information contained in this operating instructions manual is provided without liability and is subject to technical modifications.

Explanation of the symbols used

Information, hint, note: This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.

Appropriate use

The Schmersal range of products is not intended for private consumers.

The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the
chapter “Product description”.

General safety instructions

The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules.

****Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet:products.schmersal.com.

Product description

Ordering code

Product type description:
AZ 16-(1)ZV(2)K-(3)-(4)-(5)

(1)


without| 1 NO contacts/1 NC contact
02| 2 NC contact
03| 3 NC contact
12| 1 NO contact/2 NC contacts
(2)
without| Ejection force
R| Latching force 30 N
(3)
G24| with LED (only available for version with one NO and one NC contact)
(4)
M16| cable entry M16
M20| Cable entry M20
ST| Connector M12, 4 pole, bottom
STL| Connector M12, 4 pole, left
STR| Connector M12, 4 pole, right
(5)
2254| Latching force 5 N
1762| Front mounting
1637| Gold-plated contacts

Special versions

For special versions, which are not listed in the ordering code, these specifications apply accordingly, provided that they correspond to the standard version.

Purpose
The safety switches with separate actuator are suitable for sliding, hinged and removable safety guards, which need to be closed in order to ensure the necessary operational safety.
The safety switches are used for applications, in which the hazardous situation is terminated without delay when the safety guard is opened.

When the safety guard is opened, the NC contacts are positively opened and the NO contacts are closed.
The safety switchgears are classified according to EN ISO 14119 as type 2 interlocking devices.

The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety
level.
The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant
standards.

Warning about misuse
In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.

Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with the operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden, the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device.

Technical Data

Certificates| TÜV
cULus
CCC
---|---

General data
**** Standards| EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1
---|---
Coding level according to EN ISO 14119| Low
Working principle| electromechanical
Housing material| Plastic, glass-fibre reinforced thermoplastic, self- extinguishing

Gross weight :  125 g
General data – Features

Number of actuating directions 3
Number of safety contacts 2
Number of cable glands 3

Safety classification
Standards| EN ISO 13849-1
Performance Level, up to| c
Category| 1
B 10D Normally-closed contact (NC)| 2,000,000 Operations
Note| Electrical life on request.
B 10D Normally-open contact (NO)| 1,000,000 Operations
Note| at 10% I e and ohmic load
Mission time| 20 Year(s)
Safety classification – Fault exclusion
Please note:| Can be used when fault exclusion for dangerous damage to the 1- channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Performance Level, up to| d
Category| 3
Note| for 2-channel use and with suitable logic unit.
Mission time| 20 Year(s)
Mechanical data
Mechanical life, minimum| 1,000,000 Operations
Latching force| 30 N
Positive break travel| 8 mm
Positive break force per NC contact, minimum| 10 N
Actuating speed, maximum| 2 m/s
Mounting| Screws
Type of the fixing screws| 2x M6
Mechanical data – Connection technique
Connector position| Bottom
Cable entry| M12 (A-coding)
Termination| Connector plug M12, 8-pole, (A-coding)
Mechanical data – Dimensions
Length of sensor| 30 mm
Width of sensor| 52 mm
Height of sensor| 90 mm
Ambient conditions
Degree of protection| IP67
Ambient temperature| -30 … +80 °C
Storage and transport temperature, minimum| -40 °C
Storage and transport temperature, maximum| +85 °C
Permissible installation altitude above sea level, maximum| 2,000 m
Ambient conditions – Insulation values
Rated insulation voltage U| 500 V
Overvoltage category| III
Degree of pollution| 3
Rated impulse withstand voltage, connector 8-pole| 0.8 kV
Electrical data
Thermal test current| 10 A
Required rated short-circuit current| 1,000 A
Switching element| NO contact, NC contact
Switching principle| slow action, positive break NC contact
Switching frequency| 4,000 /h
Material of the contacts, electrical| Silver
Electrical data – Safety contacts
Voltage, Utilization category AC-15| 230 VAC
Current, Utilization category AC-15| 4 A
Voltage, Utilization category DC-13| 24 VDC
Current, Utilization category DC-13| 2 A
Note, Utilization category DC-13| Connector 8-pole
Electrical data – Auxiliary contacts
Voltage, Utilization category AC-15| 230 VAC
Current, Utilization category AC-15| 4 A
Voltage, Utilization category DC-13| 24 VDC
Current, Utilization category DC-13| 2 A
Note, Utilization category DC-13| Connector 8-pin

Basically suitable up to Cat. 1 / PL c.
With 2-channel usage with fault exclusion mechanism (if a fault exclusion to the 1-channel mechanics is authorised) and suitable logic applicable up to Cat. 3 / PL d

(Determined values can vary depending on the application-specific parameters hop , d op and tcycle as well as the load.)
If multiple safety components are wired in series, the Performance Level to EN ISO 13849-1 will be reduced due to the restricted error detection under certain circumstances.

Mounting

Please observe the relevant requirements of the standards ISO 12100, ISO 14119 and ISO 14120.
The mounting dimensions are indicated on the rear of the component. The enclosure must not be used as an end stop.
Any mounting position. The mounting position however must be chosen so that the ingress of dirt and soiling in the used opening is avoided. The unused openings must be sealed by means of slot sealing plugs (AZ 15/16 – 1476-1 available as accessory) after fitting.

Mounting of the actuator

See operating instructions Actuator.
The actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling of the screw heads).

Actuating radii [mm]| over the small edge of the actuator
| over the wide edge of the actuator

---|---|---
AZ 15/16-B2| Rmin
–| d
–| Rmin
45| d
11
AZ 15/16-B2-1747| –| –| 45| 11
AZ 15/16-B3| 32| 11| –| –
AZ 15/16-B3-1747| 32| 11| –| –
AZ 15/16-B6| 25| 11| 38| 11

Dimensions
All measurements in mm.

Front mounting

Electrical connection

General information for electrical connection
The electrical connection may only be carried out by authorised personnel in a de-energised condition.

The contact labelling can be found in the wiring compartment of the switch. Appropriate cable glands with a suitable degree of protection are to be used.

Settle length x of the conductor: 6 mm

After wiring, dust and soiling must be removed from the wiring compartment. The safety switch is double insulated. The use of a protective ground connector therefore is not authorised.
Contact Options

AZ 16ZV.K AZ 16-02ZV.K AZ 16-12ZV.K
**** **** ****
AZ 16-03ZV.K AZ 16ZV.K-ST AZ 16-02ZV.K-ST
**** **** ****
AZ 16-12ZV.K-ST LED LED
**** **** ****

Legend
**| zwangsöffnender Öffnerkontakt
**
| Schließerkontakt
**| Öffnerkontakt**

Set-up and maintenance

The safety function of the safety components must be tested. In the case of correct installation and adequate use, the safety switchgear features maintenance-free functionality. A regular visual inspection and functional test, including the following steps, is recommended:

  1. Check for free movement of the actuating element
  2. Check cable entry and connections
  3. Check the switch enclosure for damage
  4. Remove particles of dust and soiling

Adequate measures must be taken to ensure protection against tampering either to prevent tampering of the safety guard, for instance by means of replacement actuators.
Damaged or defective components must be replaced.

Disassembly and disposal

Disassembly
The safety switchgear must be disassembled in a de-energised condition only.
Disposal
The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.

Schmersal Ltd., Sparrow hawk Close, WR14 1GL Malvern
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 18/10/2023, 11:40

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals