DEWERT OKIN CB4530 Control Box Instructions

June 16, 2024
DEWERT OKIN

Test instruction for
Control Box
Instructions

CB4530 Control Box

Scope PM/I and the relevant manufacturing plants

  1. Purpose
    This test instruction describes the incoming goods inspection of the cinemini control box and the FS.03.03.01

  2. Terms and abbreviations
    – none –

  3. Competence
    Initiator of creation: Luca Zannoni 27/09/2023
    Creator of the instruction: Luca Zannoni 27/09/2023
    Initiator of modification: Luca Zannoni 24/10/2023
    Creator of the modified instruction: Luca Zannoni 24/10/2023

  4. Change information
    Index| Date| Changing| Workflow| Name
    ---|---|---|---|---
    0| 27.09.2023| • First Release| | Zannoni
    1| 20.10.2023| • Added Switch FS03.03.01 and Heating
    Pad| | Zannoni
    2| 23.10.2023| • Clarified some points| | Zannoni
    3| 24.10.2023| • Added switch buttons description| | Zannoni
    4| 30.10.2023| • Added third motor| | Zannoni

  5. Procedure/method description
    – see the following pages –

  6. Applicable documents
    – documented processes; documents in bills of materials; ERP system –

  7. Documentation
    All pictures shown are for illustration purpose only. Actual product may vary.

Required testing equipment

  • Remote RF34 part number RF34.03.03 – (1)
  • One motors Switch – FS03.03.01 – (2)
  • Motor1: Actuator JLDQ.20.472.172K01 – (3)
  • Motor2: Actuator with 2 Pins standard connection – (4)
  • SMPS 29VDC JLDP.10.057.001 – (5)
  • Controlbox Cinemini(ID: ????) – (6)
  • Cable R12.612.01.079 – (7)
  • Cable R12.204.01.008 – (8)
  • Heating Pad R5.229.01.033 (9)
  • Motor2: Actuator with 2 Pins standard connection – (10)
  • Cable xxxxxxxx (11) (drawing attached)

Preparation / Connecting

DEWERT OKIN CB4530 Control Box - Connecting

Appendix:

RF34_Remote_cinema
-User Manual_Rev0.1.pdf

Testing

  • Perform the pairing procedure on the remote
  • Press open button on the remote
    • The 3 motors should open
  • Press close button on the remote
    • The 3 motors should close
  • Press motor1 up button on the switch
    • Motor1(Item 3) should open
  • Press motor1 down button on the switch
    • Motor1 (Item 3) should close
  • Press the Red Button on the Switch a First Time
    • A Low Red Light turns On and the Heating Pad warms up
  • Press the Red Button on the Switch a Second Time
    • The Red Light colour becomes more Intense
  • Press the Red Button on the Switch a Third Time
    • The Light turns to the Initial Colour and the Heating Pad turns Off

NOTE: No temperature measurement is needed for the Heating Pad thresholds.

FCC Warnning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

ISED Statement
This device complies with Industry Canada license‐exempt RSS standard(s).
Operation is subject to the following two conditions: (1) This device may not cause interference, a nd (2) This device must accept any interference, including interference that may cause undesired operation of the device.
The digital apparatus complies with Canadian CAN ICES‐3 (B)/NMB‐3(B).
This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DEWERT OKIN User Manuals

Related Manuals