COSTWAY ES10261US Dehumidifier User Manual

June 16, 2024
COSTWAY

COSTWAY ES10261US Dehumidifier User Manual

Before You Start

Please read all instructions carefully.
Retain instructions for future reference.
Separate and count all parts and hardware.
Read t0hrough each step carefully and follow the proper order.
We recommend that, where possible, all items are assembled near to the area in which they will be placed in use, to avoid moving the product unnecessarily once assembled.
Always place the product on a flat, steady and stable surface.
Keep all small parts and packaging materials for this product away from babies and children as they potentially pose a serious choking hazard

Please keep this manual carefully for further reference!

Thank you for selecting our dehumidifier. Be sure to read this manual carefully before using it. Any questions, please contact the professional service for help.

FOR YOUR SAFETY

Your safety is the most important thing we are concerned

WARNING
Please read this manual carefully and fully understand before operating your dehumidifier.

OPERATIONAL PRECAUTIONS

WARNING – to reduce the risk of fire, electric shock or injury to persons or property:

  • If the supply cord is damaged, it must be replaced by qualified persons in order to avoid a hazard.
  • The appliance shall be disconnected from its power source  during maintenance.
  • Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
  • Always use a power outlet that is grounded.
  • Unplug the power cord when cleaning or when not in use.
  • Do not operate with wet hands. Prevent water from spilling onto the unit.
  • Do not immerse or expose the unit to rain, moisture or any other liquid.
  • Do not leave the unit running unattended. Do not tilt or turn over the unit.
  • Do not unplug while the unit is operating.
  • Do not unplug by pulling on the power cord.
  • Do not use an extension cord or an adapter plug.
  • Do not put objects on the unit.
  • Do not climb or sit on the unit.
  • Do not insert fingers or other objects into the air outlet
  • Do not touch the air inlet or the aluminum fins of the unit.
  • Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
  • Do not clean the appliance with any chemicals.
  • Ensure the unit is far away from fire, inflammable, or explosive objects.
  • The unit shall be installed in accordance with national wiring regulations.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.
  • The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • Do not piece or burn, even after use.
  • e aware that refrigerants may not contain an odour.
  • Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than 4m²/43 sq.ft
  • Compliance with national gas regulations shall be observed.
  • Keep any required ventilation openings clear of obstruction.
  • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.

WARNING
Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry, recognized assessment specification.

INSTALLATION

LOCATION
Installation

  1. Place the unit on a firm, level surface in an area with at least 30cm/12” of free space around it allow for proper air circulation.
  2. Never install the unit where it could be subject to:
    • Heat sources such as radiators, heat registers, stoves or other products that products that produce heat.
    • in an area where oil or water may be splashed
    • Direct sunlight
    • Mechanical vibration or shock
    • Excessive dust
    • Lack of ventilation, such as cabinet or bookcase
    • Uneven surface

OPERATING THE DEVICE SAFELY

  • Check the device after unpacking for any damages or scratches on it.
  • Operate this unit in an ambient temperature from 5°C to 35°C/41 ℉-95℉.
  • Do not use outdoors. This dehumidifier is intended for indoor residential applications only.
  • Do not operate in close proximity to walls, curtains, or other objects that may block inlet and outlet.
  • Keep the air inlet and outlet free of obstacles.
  • If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.
  • Keep doors and windows close for better energy saving.
  • Do not operate or store the unit in direct sunlight or rain.
  • It is normal for air outlet to feel warm to touch after continuous operation on hot days.
  • Empty the water tank before moving dehumidifier.
  • Make sure the Water tank is correctly fitted otherwise the unit will not operate properly.
  • The dehumidifier starts up in the mode selected when the unit was last used.
  • The dehumidifier starts dehumidifying if the room humidity is 3% higher than the selected humidity.
  • There is a protective 3-minutes time delay of the compressor. Wait 3 minutes for the dehumidifier to resume dehumidification

PRODUCT OVERVIEW

Product Overview

FEATURES

  • Powerful moisture removal
  • Washable Filter
  • Continuous Drainage or 2L Water Tank
  • Clothes Drying Function/ Auto-Defrost
  • Humidity Monitor shows current air humidity.
  • Auto mode automatically adjusts humidity levels.
  • Electronic control/Auto shut-off/ Auto restart
  • Effectively removes moisture, dust, and dust mites from the air.
  • Low power consumption-energy efficient.
  • A 24-hour timer to set the time of operation.
  • Quiet fan has two speed setting

OPERATION

CONTROL PANEL
Operation
Power
In the standby state, press the power button to turn on, the operation indicator lights up and the default fan speed is high, and the default humidity is 50%. In the power-on state, press the power button to turn off, the running indicator light goes off and the compressor stops immediately, and then the fan shut down after 10 seconds delay
Humidity
Touch the humidity button to check the current environment humidity, touch this button again and you can set the humidity. The range of target humidity is 30%- 35% – 40% – 45% – 50% – 55%- 60% – 65% -70% – 75%- 80%. After setting 3 seconds, the system  confirms the input value and then the machine exits the setting state, and returns the current humidity. In the drying mode, the target humidity cannot be changed. Long Press humidity button for 5 seconds to display the current ambient temperature.
Mode
Auto mode – continuously drying mode cycle, press once to switch the mode from one to another, the corresponding indicator lights up.

  • Auto mode: Machine operate under default humidity 50% RH. Both fan speed and humidity can be adjusted under auto mode.
  • Continuously drying mode: The machine continues to run, but the humidity can not be adjusted.

Timer
Press the timer button to set the 0-24 hour timing function. The interval is 1 hour. Each time you press this button, the value  increased 1 hours and then the corresponding timing value is displayed on the screen. The setting value is “00” to cancel the timer   function. The indicator turns out. After the timer is set and completed, the timer LED is on during the timing period. After the timing is over, the timer LED turns off automatically. In the running state, set the time to turn off the machine; in the standby state, set the time to turn on the machine.
Sleep mode
Touch the sleep button, the button lights up and start the sleep function. After no operation, all indicators turns dark gradually and the wind speed is automatically switched from high to low. Touch any button to wake up the indicator. Touch sleep button again to exit the sleep mode.
When environmental humidity ≤ 57%,compressor stops working and the fan shut down after 30 seconds delay.
When environmental humidity ≥ 63%,the fan starts working and compressor starts working after 3 seconds.
Fan speed and humidity can not be adjusted under sleeping mode.
Fan
High wind – low wind cycle, press button once to switch and then the corresponding indicator lights up. In continuously drying mode, sleep mode and defrosting period, the wind speed can not be changed.
Child Lock
Long press 3 seconds to turn on/off the child lock function.

Water Tank Full Alarm

Water Tank Indicator

  • When the tank is full for 5 seconds, it sets the alarm. The water tank indicator turns red and the unit buzzes for 15 times.

Clear the alarm

  • When the buzz is on, press any button to stop it. The compressor, fan and ionizer generator shut down and all the functions freeze until the tank is emptied and back in right position.

Empty the tank

  • Grab the notch at the bottom of the tank and pull it out with both hands.
    Take it slowly and steadily in case of spilled water

  • Empty the water.

  • Put the water tank back in position. The dehumidifier automatically starts working again

MAINTENANCE

Precautions

Precautions

  1. Do not remove the float out the tank. If the float in the tank is removed, the machine will not turn on or start up.
  2. If the tank is dirty, wash it with warm water. Do not use cleaners or steel balls, chemically treated dust-proof cloth, gasoline, benzene, thinners or other solvents chemically as they may damage the water tank and cause leakage.
  3. Continuous Drainage
    • Take out the water tank
    • Use a water hose(diameter=9.5mm) to conn ct the water outlet.
    • asses the water hose through the cutting hole in the tank and put the tank back.

For continuous drainage, the end of the hose should not be submerged in water to prevent it from being blocked or damaged

CLEANING THE AIR FILTER (every two weeks)

Note: before cleaning and maintaining the machine, be sure to turn off the machine and pull the power plug to prevent electric shock.

Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit.

The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.
Cleaning The Air Falter

  1. Remove the filter frame and take off the filter.

  2. Use a vacuum cleaner to gently absorb the dust on the surface.
    If the filter is very dirty, wash it with water and a soft detergent and dry it thoroughly afterwards

  3. Put the filter back

STORAGE AND DISPOSAL

STORAGE
Long-term storage – If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely.

Please store the unit per the following steps.

  1. Unplug the unit.
  2. Empty the water tank and dry with a cloth.
  3. Clean the filter and let the filter dry completely in a shaded area.
  4. Collect the power cord at the tank and re-install it.
  5. Re-install the filter at its position.
  6. Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoors.
  7. The unit must be kept in upright position when in storage.

ATTENTION: The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds.  Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is to set the humidity point more than 5% higher than the ambient humidity to force the fan to dry the evaporator for a couple of hours.

DISPOSAL
Cautions: Switch off the unit and unplug it immediately if anything abnormal happens. Then contact a qualified electrician.

WARNING
Releasing refrigerant into atmosphere is strictly forbidden!
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If  electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being

TROUBLE SHOOTING

FUNCTIONING TEMP
5℃/41℉ ≤ Ambient Temp.≤ 35 ℃/95 ℉
When the ambient temp is lower or higher than the functioning temp, the dehumidifier stops.
When 5℃/41℉ ≤ Ambient temp≤ 16℃/61℉, the compressor automatically defrosts at intervals; during defrosting, the compressor stops and the fan keeps running.

BEFORE CALLING FOR SERVICE   |
Before contacting professional service, please review the trouble shooting list that includes common occurrences that are not the result of a defect in workmanship or materials.

Problem Possible Cause Solution
Not working No power supply Connect to a functioning outlet and switch on
Water Full Indication Flashes Drain water tank and reset it, or re-position

the water tank to right place
Room temperature ˂5°C/41℉, or ˃ 38 °C/100℉| Self-Protection designed to protect the unit. Can not work under such temperature
Bad functioning| Is the air filter clogged?| Clean the air filter as instructed
Is the intake duct or discharge duct obstructed?| Remove the obstruction from the discharge duct or intake duct.
No air intake| Is the filter clogged?| Wash the filter
Loud noise when running| Is the machine put in the plat place?| Put the machine on the plat ground
Is the filter clogged?| Wash the filter

Company logo