whitehallmfg WHRC2142-W-2 Wall Waste Toilet Instruction Manual
- June 16, 2024
- whitehallmfg
Table of Contents
whitehallmfg WHRC2142-W-2 Wall Waste Toilet Instruction Manual
Important: Some options may slightly alter installation. To ensure proper installation review the manual thoroughly and verify rough-ins before beginning any work. File this manual with the owner or maintenance personnel upon completion of installation.
MGI Engineered Plumbing Products are designed in accord with applicable National Codes and Standards, which may include UPC, ANSI, and ASSE. Installers should use industry standard practice for details not covered within Manual. Prior to installation, supply lines must be flushed of all foreign material such as pipe dope, chips, or solder. Debris or foreign material in water supply may damage valve. An appropriate thread sealant is recommended on all threaded waste and supply connections to reduce the possibility of leaks. Toilet requires a minimum of 25 PSI flow pressure and uses a minimum water consumption of 1.28 GPF.
ANSI, UFAS or ADAcompliance is subject to the interpretation and requirements of the local code authority and is the responsibility of the installer for verification
TOILET WASTE CONNECTIONS
Units with Wall Waste Outlets are provided using a 5-1/2” Diameter Recessed
Gasket Flange and Floor Waste units will receive a 7-1/2” Diameter Recessed
Gasket Flange. The Stainless Steel Gasket Flange is welded in place to the
Toilet P-trap, and is fabricated to be flush with the back of the unit (wall
outlet) or flush with the bottom of the fixture (floor outlet). The depth of
the Recessed Gasket Flange is 1/2” deep.
The Recessed Gasket Flange is intended for installation and assembly with a common 3” or 4” Toilet Closet Flange Fitting, Yoke Adapter or similar. The Recessed Gasket Flange provided includes (2) 5/16” UNC Threaded Captive Nuts, which are on 6” centers. These tapings allow for assembly of Closet Bolts and may assist to provide for the Squeeze of the Gasket to seal the waste connection. Certain installation conditions may not require using the tapings. Choice of the Gasket material is up to the installer however, it is common for Neoprene or Felt Gaskets to be used with Wall Waste Toilet units.
TECHNICAL DIMENSIONS
Top View
Side View
WHRC2142-W-2
Side View
WHRC2142ADA-W-2
TOP SUPPLY
Top View
Side View
WHRC2142-W-2
Side View
WHRC2142ADA-W-2
NOTE: All dimensions are in Inches (mm)
- Toilet
- Access Panel with Vandal Resistant Fasteners
- Existing (4) Bolt, Wall Mounting Carrier shown for reference only
- Ligature Resistant Toilet Seat Cover
- 1-1/2” NPT Male Top Supply Flush Inlet
- Flush Valve Shown for reference only and is not included.
ROUGH-IN DIMENSIONS
Ligature Resistant Toilets require specific Flush Valve model to suit application for Supply Type (Concealed / Exposed), Flow Rate and ® ADA Accessibility (when applicable). Refer to the following WhiteHall Accessories:
- Concealed Flush Valve Access Panel: Model WH2898 and WHD2898 for ADA
- Exposed Flush Valve Cover: WH2802-SLPT and WH2802-SLPT -ADA
WALL SUPPLY
Front View
*Note: Dimensions shown “As Required” for will be as originally provided to Factory by customer on Submittal form
TOP SUPPLY
Front View
*Note: Flush Valve Supply Inlet dimensions provided are for reference only and coordinate with Whitehall Manufacturing optional models WH802-SLPT and WH2802-SLPT-ADA Top Supply Flush Valve covers. Installer shall determine Flush valve location to suit project requirements.
- 5-1/2” Recessed Gasket Flange (Flush with back of fixture for connection to Closet Flange)
- Existing (4) 5/8” UNC Support Carrier Threaded Studs
- 1-1/2” NPT Female Wall Supply Flush Inlet Connection
- 1” NPT Female Top Supply Inlet Connection
INSTALLATION DETAILS
Top View
- Existing Adjustable Flange (By Others)
- Existing (4) 5/8” UNC Support Carrier Threaded Studs
- Access Panel and 1/4”-20 Fasteners
- Neoprene Gasket (By Others)
INSTALLATION
A. Removal of bolts holding old Toilet as well as the removal of old
Toilet
B. Slide new Toilet over existing Hardware
C. Remove Access Panel and Fasteners [3] make up toilet waste connection.
D. Reconnect existing Flush Valve to fixture as required per
manufacture’s recommendation
PLASTIC SEAT INSTALLATION
INSTALLATION INSTRUCTIONS:
Prior to installing, Verify if the following is Included:
Carriage Bolts [1], Tapered Nuts [2], Front Set Screw [3], and Toilet Seat
[4].
A. Partially install Front Set Screw [3] into the Mounting Tab [5]
located at the front of the Toilet Seat [4]. Set Screw [3] should not pass
beyond Mounting Tab [5].
B. Position the Toilet Seat [4] onto Toilet, and press down firmly.
C. Fasten the Toilet Seat [4] to the Toilet by using the Carriage Bolts
[1] on top of the Toilet Seat [4] and tighten by installing the Tapered Nuts
[2] from the underside of the Toilet rim.
D. With Toilet Seat [4] Fastened, pressed downward on Toilet Seat [4] and
tighten the Front Set Screw [3] until it firmly engages under the Flushing Rim
[6].
NOTE: If Toilet Seat has Hole Plugs, remove them prior to installing Toilet.
SLOPING FLOORS:
When required for sloping floors, refer to detail to create a level pad for
on-floor Toilet Housing.
IMPORTANT:
Sloping floor detail is provided for reference only and should not be
considered as a recommendation by the fixture manufacturer.
Installer assumes all responsibility to alterations of site conditions and
affected fixture dimensions.
Please refer to the Link or QR code provided.
For Cleaning & Care Guide:
https://www.whitehallmfg.com/uploads/fileLibrary/9900-008-W01.pdf
WHITEHALL MANUFACTURING
P.O. BOX 3527
City of Industry, CA 91744-0527 U.S.A.
Phone 800-782-7706
626-968-6681
Fax 626-855-4862
Web: www.whitehallmfg.com
References