DIGITEN DFC15 Liquid Flow Controller Instruction Manual

June 16, 2024
DIGITEN

DIGITEN DFC15 Liquid Flow Controller Liquid Flow Controller
Model: DFC15

This liquid flow controller (DFC15) is used to measure and control the flow of liquid, DFC15 can control solenoid valve on/off when the flow reaches to setting value, It is suitable for hall effect flow sensor, large LCD screen can display the flow rate, volume, and the temperature of the liquid, DFC15 have wide applications for swimming pool, Water Dispenser, coffee machine, drip irrigation system, water meter, etc,

FEATURES

Quantitative control
Controller will turn off the solenoid valve automatically when flow reaches to a certain amount you set
Monitor flow rate
Display the REAL-TIME volume of liquid per minute
Work with all hall effect flow sensor
It can work various different flow sensors by changing the K parameter
Water meter function
DFC15 can be used to measure the volume of water
Adjustable accuracy
Calibrate the accuracy by changing the K parameter
Temperature monitor
Measure and display liquid temperature
Easy-to-Read Front-Panel Liquid Crystal Display
Displays the flow total volume, flow rated and sensed temperature clearly; custom icons on the display indicate the controller working status at a glance

TECHNICAL SPECIFICATIONS

Controller Power Requirement 12VDC
Power Adapter Input 100-240VAC, Output: 12VDC, max 2A
Adapter lead length lm
Measuring Accuracy ±1%
Output for Solenoid valve 12VDC, max 2A
Temperature Sensor 0-125 L’ /32-257T NTC3950, Accuracy: ±1°C/±1°F thread: M8
Max Total Volume 999999 G/L
Quantitative Range 0-9999.99G/L
Flow Rate Range 0-9999.99/LPM(GPM)
Cable Length 1m
Dimensions 88mmx126mmx3Omm
Weight 200g
Operation Environment Temperature: 0-50 C/32-122 F

Relative Humidity: <85%

SCREEN INSTRUCTION

DIGITEN DFC15 Liquid Flow Controller - Fig

  1. Quantitative A certain setting amount
  2. Max alarm: Alarm of total volume
  3. Total Current total volume
  4. PW:Password (default 1234)
  5. L Liter
  6. Gal Gallon
  7. K K parameter
  8. LPM: Liters per minute
  9. GPM Gallons per minute
  10. Liquid temperature
  11. Alarm icon
  12. Faucet icon

KEY FUNCTION INSTRUCTION

Menu| Press MENU to switch the query: quantitative setting value, total flow value and K parameter press MENU key after setting to store the setting value and exit setting mode
---|---
SET| Long press SET to enter the parameter setting mode , short press the SET button in setting mode, change the next digit
CLEAR| Long press to clear the corresponding value
| Increase or decrease the number
RUN/STOP| Turn on/off the solenoid valve

FUNCTION INSTRUCTION

Quantitative control
The controller will turn off the solenoid valve automatically when reaches the quantitative value you set. Press the RUN/STOP button again, the controller will repeat the same job.
Max alarm function

  1. When the total amount reaches the setting value(Max alarm), the controller will alarm and the alarm icon will flash. Press any button to end the alarm sound. Alarm will be closed until change the max alarm value it is higher than total amount
  2. Change max alarm value to zero, controller will never alarm forever.

Total: Display total volume, range; 0-999999
PW: Password, K value protection password, user need to enter the password when setting K parameter.
L/Gal: Volume unit Liter/gallon K:K parameter, Different flow meter with different K values LPM/ GPM:
LPM: Liters per minute, GPM: Gallons per minute liquid temperature (Fahrenheit or Celsius degree), the temperature of the liquid can be measured
Faucet: In the RUN mode, LCD display animated water dropping under the faucet.
VIEW SETTING VALUES
Short press MENU button, it can display the values in order below;

DIGITEN DFC15 Liquid Flow Controller - Fig 1

SETTING INSTRUCTION
Please press RUN/STOP switch to the STOP status before setting,
Note: lt will exit setting mode when no operation more than 30s.
Setting quantitative value
Short press MENU button until LCD display Quantitative as the picture below

  1. Long press SET button until it beeps and quantitative value flash
  2. Poss to canoe me number .
  3. Press ser button change net number to you desired value
  4. Press MENU button to save and exit.

Setting max alarm value
Short press MENU button and until it display Max alarm

  1. Long press SET button until max alarm value flash
  2. Press to change the number.
  3. Press SET button change next number to your desired value
  4. Press MENU button to save and exit

Setting K parameter
Short press MENU button until it display K parameter as the picture below

DIGITEN DFC15 Liquid Flow Controller - Velu 2

  1. Long press SET button until LCD display
  2. Input 4-digit password (default password is 1234), After four-digit password is correctly entered, controller will switch to modifiable K value. otherwise you can’t set the K parameter.
  3. Press to change the number
  4. Press SET button change next number to your desired value
  5. Press MENU button to save and exit
    Note: Please ask manufactory fo r the flow sensor K value . And you can adjust the K value until you satisfy the measuring accuracy.

How to change password
Short press MENU button and until it display K parameter as the picture below

DIGITEN DFC15 Liquid Flow Controller - Password

  1. Long press CLEAR button it beeps and until password flash 0- – – ..,

  2. Input current 4-digit password (default password is 1234), After fo ur-digit password is correctly password entered, controller will allow you to change the

  3. Press A o to change the number

  4. Once controller password has been changed, LCD will return to default display

DIGITEN DFC15 Liquid Flow Controller - Password 1

Note: If you forget current password, you can restore factory setting, if so, all setting values will be restored to factory setting.
How to restore factory setting
Keep pressing RUN/STOP button until connect the power to this device, controller will restore factory setting
How to change volume unit
To convert to gallon unit, press the and buttons simultaneously Press them again to return to Liter unit.
Change temperature unit
To convert to Fahrenheit unit, press the MENU and buttons simultaneously. Press them again to return to Celsius unit.
Water meter function
Changing quantitative value to zero, this controller can be used as water meter.
CLEAR VALUE
Press MENU button to switch to the desired display, long press CLEAR button about 3s until it beeps.
Only Total volume, Quantitative value and Max alarm value can be cleared by pressing CLEAR button

Clear Total volume value

  1. Short press MENU button until it display Total as le ft picture.
  2. Lon g press CLEAR button about 3s until the total volume is cleared.

INSTALLATION INSTRUCTION

DIGITEN DFC15 Liquid Flow Controller - Password 3

  1. Ensure the solenoid valve and flow sensor direction is the same with water flow
  2. Please ignore positive pole and negative pole of the solenoid valve.
  3. Avoid the water into the controller
  4. Please use teflon on the thread when requirement, ensure don’t leak.
  5. The wires can be extended up to 10m.
    Note: This controller work with the solenoid valve up to SA. but this kit come with 2A power adapter, if drive a large solenoid valve, please use suitable power adapter.

HOW TO WORK

  1. Set K parameter, quantitative value, Max alarm value, and properly install the flow sensor and solenoid valve.
  2. Press the RUN/STOP button, the controller works, Total will continuously display the current flow volume, and current flow rate, and the faucet will start animated display
  3. When the flow reaches the quantitative setting value, the controller turn off the solenoid valve automatically, and the total value stop, faucet animation will be stop dropping, flow rate back to zero.
  4. Press the RUN/STOP button again and the controller will repeat the same job.

TROUBLESHOOTING

If the controller does not function properly, verify that the unit is wired, configured, and set properly If the problem persists, use the following procedures to determine the cause of the problem.
Measuring inaccuracy
Generally the accuracy of controller depends on the flow sensor
a If the measurement accuracy is inaccurate, consult the flow sensor factory for an accurate K value.
b. By constantly adjusting the K value to achieve the corresponding accuracy, at the same time due to the different liquid media pressure, need to adjust the K value
c. The smaller the diameter of the flow meter, the higher accurate the accuracy
Power adapter very hot or burned
This controller can work with load up to 5A, please confirm if the adapter meet the solenoid valve power. If the solenoid valve power is more than the adapter, the adapter will become very hot and even burned
RuN mode failure
LCD display animated water drop, but total volume and flow rate don’t change properly.
Please restore the controller to factory setting
Water releasing problem
The green RUN led is on when press RUN/STOP. But water can’t be released

  1. Make sure the solenoid valve is fine. Disconnect the solenoid valve to controller, use a 12VDC power to connect to this solenoid valve, if hear the sound of coil triggering, it indicated the solenoid valve works fine and see next step. otherwise, please exchange a new solenoid valve
  2. Use a reliable multi-meter, to measure the voltage of the 2 wires for the solenoid valve. Press RUN/STOP to run the controller. If the voltage reading is 12vDC, it indicated the controller works fine, otherwise see next step.
  3. Ensure the power adapter is 12VDC, and output current meet the solenoid valve requirement.

If the problem persists after trying the troubleshooting steps. Please send your questions to our customer service: service@digit- en.com

WARRANTY

The DIGITEN products are guaranteed to the original owner for one year against defects in workmanship and materials. Please contact us service@digit- en.com
www.digit-en.com
WARNING
This device isn’t waterproof, please don’t install in water, and avoid being caught in rain.

COPYRIGHT 2022 DIGITEN CO.,LTD ALL RIGHTS RESERVED
www.diit-en.com
service@digit-en.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals