DIGITEN TTC-1003 Temperature Controller with Timer User Manual

June 15, 2024
DIGITEN

DIGITEN TTC-1003 Temperature Controller with Timer

DIGITEN-TTC-1003-Temperature-Controller-with-Timer-
PRODUCT

The thermostat with timer is specially designed for pet breeders. The large LCD display makes your settings or monitoring clear at a glance. Two sets of probes can control different pets respectively. The controller has three outlets, the first and second are temperature control and time control, the third is timing switch control, and the three work independently without interfering with each other. Different temperature or lighting needs can be set for your pet during the day and night. Intelligent control allows pets to live in a comfortable environment forever.

FEATURE

  • The timer is for day and night temperature control.
  • The three outlets work independently without interfering with each other.
  • A button battery is included to store the current time.
  • Power-off memory function, all settings will be saved when power is off.

OVERVIEW

DIGITEN-TTC-1003-Temperature-Controller-with-Timer-
FIG-1

  1. OUT1: Outlet 1#, Temperature Controller & Timer
  2. OUT2: Outlet 2#, Temperature Controller & Timer
  3. OUT3: Outlet 3#, Timer
  4. P1: Probe for OUT1
  5. P2: Probe for OUT2
  6. HEATING/COOLING: Working Mode of OUT1/OUT2
  7. OFF/ON: Working Status of OUTs
  8. Current Time
  9. OUT1 Current Temperature
  10. OUT2 Current Temperature
  11. AH: High Temperature Alarm
  12. AL: Low Temperature Alarm
  13. CA: Temperature Calibration
  14. DP: Time of Compressor Delay Starting

SPECIFICATION

Power Requirement 100-240VAC
Load Capacity 100-240VAC 10A Per Outlet 1100W@110V, 2200W@220V
Temperature Control Range -10’C ~ 120’C /14 ‘F ~ 248 ‘F
Measuring Accuracy ± 1’C/± 1 ‘F
Probe Sensor Type NTC 3950, R25=10K
Probe Sensor Length 2m/6.56ft
Power Cable Length 1.4m/4.6ft
Measurement 105mm(L)X105mm(W)X32mm(H)
Operation Environment Temperature: 0-50’C /32-122 °F Relative Humidity: <85%

SETTING RANGE

Function Setting range Default
Temperature ON Value -10″C- 120″C/14°F- 248°F 28°C /82 °F
Temperature OFF Value -10″C- 120″C/14°F- 248°F 30″C/86 °F
AH high temp alarm -10″C- 120″C/14°F- 248°F OFF
AL low temp alarm -10″C- 120″C/14°F- 248°F OFF
CA calibration -15″C- 15°C / -15 °F- 15 °F 0.0
DP compressor delay start -10″C- 120″C/14°F- 248°F 0

SETTINGS

SET CURRENT TIME

  • Press and hold CLOCK until the current time flashes, press or to adjust the hour, press CLOCK to set the minute and press or to adjust it, then press CLOCK to save and exit.

CHANGE TEMPERAURE UNIT

  • Press and hold and simultaneously for about 3s to switch between Fahrenheit and Celsius units.

SET OUT 1/OUT 2

  1. Press SET until the LCD display , press or to choose the OUT1/OUT2.
  2. To set OUT1, press and hold SET for about 3s, the ON time will flash, press or to adjust the hour, then press SET to set the minute and press or to adjust it.
  3. Press SET to set OFF time, press or to adjust the hour, then press SET to set the minute and press or to adjust it.
    • If you domt need a timer, press or to adjust time to .
  4. Press the SET to set the ON temperature value, press or to adjust the value you desired.
  5. Press SET to set the OFF temperature value and press or to adjust it.
    • To set ON value > OFF value, it will be in cooling mode, COOLING icon will be displayed under OUT icon on the left of the display.
    • To set ON value < OFF value, it will be in heating mode, HEATING icon will be displayed above OUT icon on the left of the display.
  6. Press SET to set the AH if you need. The default value of OFF is permanently off.
  7. Press SET to set the AL if you need.
  8. Press SET to set the CA if you need.
  9. Press SET to set the DP if you set it COOLING mode.
  10. Press SET to the last value or press and hold the SET to save and exit.
  11. Set the OUT2 according to steps 1~10.

SET OUT 3

  1. Press SET until the LCD display , press or to choose the OUT3.
  2. Press and hold SET for about 3s, the jON hour will flash, press or toadjust it,
  3. Press SET to set the 1 ON minute and press or to adjust it.
  4. Press SET to set the 1 OFF hour and press or to adjust it.
  5. Press SET to set the 1 OFF minute and press or to adjust it.
  6. Press SET to set the second time period( 2 ON /2 OFF) if you need, and repeat steps 2 to 5 to set hour and minute.
    • If only one time period needs to be set, after setting the first time period, adjust 2 ON/2 OFF to , you can long press SET to save and exit.

FUNCTION INTRODUCTION

Heating Mode

  • To set ON< OFF, the OUT1 (OUT2) will start to work when the current temperature is lower than the ON value, and won’t stop working until the current temperature reaches the OFF value.

Cooling Mode

  • To set ON> OFF, the OUT1 (OUT2) will start to work when the current temperature is higher than the ON value, and won’t stop working until the current temperature reaches the OFF value.

High/low temperature alarm

  • When current temperature >- AH temperature, high temperature alarm will be triggered.
  • When current temperature <- AL temperature, low temperature alarm will be triggered.
  • You can press any button to stop the alarm beep, or set AH/AL to OFF to permanently turn off the alarm.

Calibration (CA)

  • When the current temperature deviates from the actual temperature, it can be corrected with the temperature calibration function.
  • Correct temperature = temperature before calibration + calibration value (CA), the calibration value can be positive, negative, or 0.

Time of Compressor Delay Starting (DP)

  • After power-on, in cooling mode, if the current temperature ~ OFF value, the cooling device will wait for a delay time (DP) before starting.
  • When the time interval between two cooling operations is greater than the delay time (DP), the cooling device will work immediately.
  • When the time interval between two cooling operations is less than the delay time (DP), the cooling device will not start until it reaches the delay time (DP).
  • When the cooling device stops instantaneously, the stop time will be recorded as the time comparison point for the next start.

RESTORE TO FACTORY SETTING AND WARRANTY

RESTORE TO FACTORY SETTING

  • First unplug the controller to tum off the power, then press and hold SET, and then re-plug in the power again, the controller will restore to factory settings after a “beep”.

WARRANTY

  • The DIGITEN products are guaranteed to the original owner for one year against defects in workmanship and materials.
  • If you encounter any problems while using our products, please feel free to contact us.

service@digit-en.com
www.digit-en.com/support

COPYRIGHT 2022 DIGITEN INC. ALL RIGHTS RESERVED

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals