U-ACC-PP-14-SENSOR-N10K Spare Sensor
Product Information
Specifications
- Catalog Number: 1244-002952
- Item Name: U-ACC-PP-14-SENSOR-N10K
- Cable Length: 3 m
- Resistance: 10000
Features
The nVent RAYCHEM U-ACC-PP-14-SENSOR-N10K is a spare temperature
sensor designed for floor heating thermostats. It offers the
following features:
- Simple and fast installation
Warning
Please ensure that nVent products are installed and used
according to the instructions provided in nVent’s product
instruction sheets and training materials. Failure to do so may
result in product malfunction, property damage, serious bodily
injury, and voiding of the warranty.
Contact Information
If you have any questions or need further assistance, please
contact nVent’s customer service representatives:
-
North America
Tel: +1.800.545.6258
Fax: +1.800.527.5703
Email: thermal.info@nvent.com -
Europe, Middle East, Africa
Tel: +32.16.213.511
Fax: +32.16.213.604
Email: thermal.info@nvent.com -
Asia Pacific
Tel: +86.21.2412.1688
Fax: +86.21.5426.3167
Email: cn.thermal.info@nvent.com -
Latin America
Tel: +1.713.868.4800
Fax: +1.713.868.2333
Email: thermal.info@nvent.com
Brand Portfolio
nVent is proud to offer a powerful portfolio of brands,
including:
- CADDY
- ERICO
- HOFFMAN
- RAYCHEM
- SCHROFF
- TRACER
Disclaimer
Please note that nVent reserves the right to change
specifications without notice.
Product Usage Instructions
To use the nVent RAYCHEM U-ACC-PP-14-SENSOR-N10K spare
temperature sensor for floor heating thermostats, please follow the
instructions below:
Installation
-
Ensure that the power to the floor heating system is turned off
before proceeding with the installation. -
Locate the existing temperature sensor in your thermostat or
heating system and disconnect it from the wiring. -
Connect the cable of the spare temperature sensor to the
corresponding wiring terminals in your thermostat or heating
system. Ensure proper polarity. -
Securely fasten the spare temperature sensor in a suitable
location, preferably in direct contact with the surface to be
heated. -
Once the spare temperature sensor is securely installed,
restore power to the floor heating system.
Usage
The nVent RAYCHEM U-ACC-PP-14-SENSOR-N10K spare temperature
sensor is designed to monitor the temperature of the floor heating
system. It provides accurate temperature readings for optimal
control and comfort.
Ensure that the spare temperature sensor is properly connected
and functioning by checking the temperature readings on your
thermostat or heating system display. If the readings are not
within the expected range, please refer to the troubleshooting
section in your thermostat or heating system manual or contact
nVent customer service for assistance.
Maintenance
The spare temperature sensor does not require regular
maintenance. However, it is recommended to periodically check for
any signs of damage or loose connections. If any issues are
detected, please follow the installation instructions to replace or
repair the sensor as necessary.
Disposal
When disposing of the spare temperature sensor, please adhere to
local regulations and guidelines for electronic waste disposal. Do
not dispose of the sensor in regular household waste.
Troubleshooting
If you encounter any issues with the nVent RAYCHEM
U-ACC-PP-14-SENSOR-N10K spare temperature sensor or have any
questions regarding its usage, please refer to the troubleshooting
section in your thermostat or heating system manual. You can also
contact nVent customer service for further assistance.
FAQ
Q: Can I use the spare temperature sensor with any floor
heating thermostat?
A: The nVent RAYCHEM U-ACC-PP-14-SENSOR-N10K spare temperature
sensor is designed specifically for floor heating thermostats. It
is recommended to check compatibility with your thermostat model
before installation.
Q: How long is the cable of the spare temperature sensor?
A: The cable length of the nVent RAYCHEM U-ACC-PP-14-SENSOR-N10K
spare temperature sensor is 3 meters.
Q: What is the resistance of the spare temperature sensor?
A: The resistance of the nVent RAYCHEM U-ACC-PP-14-SENSOR-N10K
spare temperature sensor is 10000 Ohms.
SPARE SENSOR
nVent RAYCHEM U-ACC-PP-14-SENSOR-N10K is a spare temperature sensor for floor heating thermostats
FEATURES
Simple and fast to install
SPECIFICATIONS
Catalog Number
1244-002952
Item Name
U-ACC-PP-14-SENSOR-N10K
Cable Length
3 m
Resistance
10000
WARNING
nVent products shall be installed and used only as indicated in nVent’s
product instruction sheets and training materials. Instruction sheets are
available at www.nvent.com and from your nVent customer service
representative. Improper installation, misuse, misapplication or other failure
to completely follow nVent’s instructions and warnings may cause product
malfunction, property damage, serious bodily injury and death and/or void your
warranty.
North America Tel +1.800.545.6258 Fax +1.800.527.5703 thermal.info@nvent.com
Europe, Middle East, Africa Tel +32.16.213.511 Fax +32.16.213.604 thermal.info@nvent.com
Asia Pacific Tel +86.21.2412.1688 Fax +86.21.5426.3167 cn.thermal.info@nvent.com
Latin America Tel +1.713.868.4800 Fax +1.713.868.2333 thermal.info@nvent.com
Our powerful portfolio of brands:
nVent.com CADDY ERICO HOFFMAN RAYCHEM SCHROFF
TRACER
© 2023 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of
1
their respective owners.
nVent reserves the right to change specifications without notice.
References
- Building a more Sustainable and Electrified World | nVent
- Building a more Sustainable and Electrified World | nVent