nVent RAYCHEM E-40 Heat Shrink User Manual

October 29, 2023
nVent RAYCHEM

RAYCHEM
End Seal

E-40 Heat Shrink

E-40

XTV ATEX / UKEX IECEX

SGS20ATEX0049X /
BAS21UKEX0499X
II 2 G Ex 60079-30-1 eb IIC T* Gb
II 2 D Ex 60079-30-1 tb IIIC
T°C Db
 II 2 G Ex 60079-30-1 eb mb IIC
T* Gb
II 2 D Ex 60079-30-1 mb tb IIIC
T*°C Db Tmin –60°C| IECEx BAS.06.0044X
Ex 60079-30-1 eb IIC T
Gb
Ex 60079-30-1 tb IIIC T
°C Db
Ex 60079-30-1 eb mb IIC T* Gb
Ex 60079-30-1 mb tb IIIC T°C Db
Tmin –60°C
KTV| SGS20ATEX0051X /
BAS21UKEX0500X
II 2 G Ex 60079-30-1 eb IIC
T226°C (T2) Gb
 II 2 D Ex 60079-30-1 tb IIIC
T226°C Db
II 2 G Ex 60079-30-1 eb mb IIC
T226°C(T2) Gb
 II 2 D Ex 60079-30-1 mb tb IIIC
T226°C Db
Tmin –60°C| IECEx BAS.06.0046X
Ex 60079-30-1 eb IIC T226°C
(T2) Gb
 Ex 60079-30-1 tb IIIC T226°C Db
Ex 60079-30-1 eb mb IIC
T226°C(T2) Gb
Ex 60079-30-1 mb tb IIIC
T226°C Db
Tmin –60°C
---|---|---
HTV| PTB 21 ATEX 1003 X /
BAS21UKEX0649X
II 2 G Ex 60079-30-1 eb IIC T
Gb
II 2 D Ex 60079-30-1 tb IIIC
T
°C Db
II 2 G Ex 60079-30-1 eb mb IIC
T* Gb
II 2 D Ex 60079-30-1 mb tb IIIC
T°C Db
Tmin –60°C| IECEx PTB 21.0007X
Ex 60079-30-1 eb IIC T* Gb
Ex 60079-30-1 tb IIIC T*°C Db
Ex 60079-30-1 eb mb IIC T
Gb
Ex 60079-30-1 mb tb IIIC T
°C Db
Tmin –60°C
VPL| SGS20ATEX0045X /
BAS21UKEX0503X
 I 2 G Ex 60079-30-1 eb IIC T* Gb
II 2 D Ex 60079-30-1 tb IIIC
T°C Db
 II 2 G Ex 60079-30-1 eb mb IIC
T* Gb
II 2 D Ex 60079-30-1 mb tb IIIC
T*°C Db
Tmin –60°C| IECEx BAS 06.0048X
Ex 60079-30-1 eb IIC T
Gb
Ex 60079-30-1 tb IIIC T
°C Db
Ex 60079-30-1 eb mb IIC T* Gb
Ex 60079-30-1 mb tb IIIC T**°C Db
Tmin –60°C

  • (*) By design with TraceCalc Pro® Engineering Software and as shown in the approval
    58.B.01728/21
    1 Ex e IIC T
    Gb X Ex tb IIIC T* Db X TЕМП ОКР СРЕДЫ –60 to +56°C

XTV,
KTV,
H T V,
VPL| | cCSAus Certificate 1333271
Class I Division 2 Group A, B, C, D; Class II /
III Division 2 Group E, F, G
Ex 60079-30-1 IIC T Gb
Ex 60079-30-1 IIIC T
Db
Class I Zone 1 AEx eb IIC T Gb
Zone 21 AEx tb IIIC T
Db
Only for nVent RAYCHEM XTV, KTV, HTV and VPL 1
Um= 277 V (XTV, KTV, HTV) and 480 V max (VPL)
---|---|---
| ATEX / UKEX| IECEX
---|---|---
HTV| | CL I DIV 2 GRP ABCD T CLI ZN 2 GRP IIC CLII/III DIV2 GRP
FG T
ZN 22 IIIB T*
CL I DIV 2 (ZN 2) GRP ABCD T*  CLII/III DIV 2 (ZN22*)
GRP EFG T
  -WS for CANADA
(
PER CE CODE TABLE 18)
FM20US0147X
FM20CA0073X
Um= 277 V max

  • (**) By design with TraceCalc Pro® Engineering Software and as shown in the approval
    Specific conditions of use:
    Maximum voltage: 480 V
    Maximum exposure temperature: 260°C (500°F)
    Minimum installation temperature: –60°C (–76°F)
    Installation instructions for nVent RAYCHEM E-40 end seal kit. For use with all nVent RAYCHEM XTV, KTV, HTV and VPL heat ing cables.

WARNING: To prevent elec tri cal shock, short cir cuit or arc ing, this prod uct must be in stalled cor rect ly and water ingress must be avoided before and during the in stal la tion.
Before installing this product, read the installation instructions completely.

  • Earth fault equipment protection is required for each circuit.
  • De-energise circuits before installation or servicing.
  • Keep ends of Trace heaters and kit components dry before and during installation.
  • The electrically conductive covering of this trace heater shall be connected to a suitable earthing terminal.
  • The presence of the trace heaters shall be made evident by the posting of caution signs or markings at appropriate locations and/or at frequent intervals along the circuit.
  • The insulation resistance of the trace heater shall be measured and recorded after installation and shall not less than 20 Mohm.
  • Persons involved in the installation and testing of electric trace heating systems shall be suitably trained in all special techniques required.
  • Installation shall be carried out under the supervision of a qualified person.
  • Refer to installation manual. A ground fault circuit interrupter shall be used with this device.

Important note: Heat shrink technique for E-40 kits – Step 9

Heat gun power for optimal shrinking time – 3000 W or greater is recommended. Lower power heat guns may work, but may require more time.
Recommended heat gun temperature: 600-650°C

  1. Set heat gun at maximum temperature and maximum air flow.
  2. Starting on cable end of heat shrink, hold heat gun in one position over the translucent heat shrink tubing until it turns clear (+/– 1 min). Then slowly move the heat gun around all sides until the heat shrink turns clear in this segment.
  3. Slowly move to an adjacent unshrunk translucent position and repeat for this next segment.
  4. Slowly continue along the length of heat shrink, rotating the heat gun at each segment until complete. Installation typically takes several minutes.
  5. Keep heat gun as close as possible to heat shrink (5 mm) but do not allow it to touch cable or heat shrink (to avoid burning and damaging materials).

België/Belgique
Tel.  +32 16 21 35 02
Fax  +32 16 21 36 04
salesbelux@nVent.com| Bulgaria
Tel.  +359 5686 6886
Fax  +359 5686 6886
salesee@nVent.com| Česká Republika
Tel.  +420 602 232 969
czechinfo@nVent.com
---|---|---
Denmark
Tel.  +45 70 11 04 00
salesdk@nVent.com| Deutschland
Tel. 0800 1818205
Fax  0800 1818204
salesde@nVent.com| España
Tel.  +34 911 59 30 60
Fax  +34 900 98 32 64
ntm-sales-es@nVent.com
France
Tél. 0800 906045
Fax  0800 906003
salesfr@nVent.com| Hrvatska
Tel.  +385 1 605 01 88
Fax  +385 1 605 01 88
salesee@nVent.com| Italia
Tel.  +39 02 577 61 51
Fax  +39 02 577 61 55 28
salesit@nVent.com
Lietuva/Latvija/Eesti
Tel.  +370 5 2136633
Fax  +370 5 2330084
info.baltic@nVent.com| Magyarország
Tel.  +36 1 253 7617
Fax  +36 1 253 7618
saleshu@nVent.com| Nederland
Tel. 0800 0224978
Fax  0800 0224993
salesnl@nVent.com
Norge
Tel.  +47 66 81 79 90
salesno@nVent.com| Österreich
Tel. 0800 29 74 10
Fax  0800 29 74 09
salesat@nVent.com| Polska
Tel.  +48 22 331 29 50
Fax  +48 22 331 29 51
salespl@nVent.com
Republic of Kazakhstan
Tel.  +7 7122 32 09 68
Fax  +7 7122 32 55 54
saleskz@nVent.com| Россия
Тел.  +7 495 926 18 85
Факс  +7 495 926 18 86
salesru@nVent.com| Serbia and Montenegro
Tel.  +381 230 401 770
Fax  +381 230 401 770
salesee@nVent.com
Schweiz/Suisse
Tel.  +41 (41) 766 30 80
Fax  +41 (41) 766 30 81
infoBaar@nVent.com| Suomi
Puh. 0800 11 67 99
salesfi@nVent.com| Sverige
Tel.  +46 31 335 58 00
salesse@nVent.com
Türkiye
Tel.  +90 560 977 6467
Fax  +32 16 21 36 04
salesee@nVent.com| United Kingdom
Tel. 0800 969 013
Fax  0800 968 624
salesthermalUK@nVent.com

nVent.com/RAYCHEM
©2022 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates.
All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice.
RAYCHEM-IM-EU1603-E40-ML-2205
PCN 1244-022482

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

nVent RAYCHEM User Manuals

Related Manuals