Schneider Electric XVUZ00 Series Harmony Fixing Plate Instruction Manual

June 16, 2024
Schneider Electric

Schneider-Electric-logo

Schneider Electric XVUZ00 Series Harmony Fixing Plate

Product Information

Specifications

Part Number Part Name Voltage Consumption Current
XVUC9S Top cover 24 V AC/DC, 100…240 V (50/60 Hz) 70 mA (24 V AC/DC), 45 mA

(100…240 V AC)
XVUC9SQ| Top cover (Silver)| 24 V AC/DC, 100…240 V (50/60 Hz)| 70 mA (24 V AC/DC), 45 mA (100…240 V AC)
XVUC23| Buzzer unit| 24 V AC/DC, 100…240 V (50/60 Hz)| 50 mA (24 V AC/DC), 40 mA (100…240 V AC)
XVUC24| Buzzer unit (Silver)| 24 V AC/DC, 100…240 V (50/60 Hz)| 40 mA (24 V AC/DC), 35 mA (100…240 V AC)
XVUC25| Green LED unit| 24 V AC/DC, 100…240 V (50/60 Hz)| 40 mA (24 V AC/DC), 35 mA (100…240 V AC)
XVUC26| Red LED unit| 24 V AC/DC, 100…240 V (50/60 Hz)| 50 mA (24 V AC/DC), 40 mA (100…240 V AC)
XVUC27| Orange LED unit| 24 V AC/DC, 100…240 V (50/60 Hz)| 50 mA (24 V AC/DC), 40 mA (100…240 V AC)
XVUC28| Blue LED unit| 24 V AC/DC, 100…240 V (50/60 Hz)| 50 mA (24 V AC/DC), 40 mA (100…240 V AC)
XVUC29| Multi-LED unit| 24 V AC/DC| 70 mA
XVUC29P| Multi-LED unit, Pulse signal| 24 V AC/DC| 70 mA
XVUC9V| Sound unit| 24 V AC/DC| 50 mA
XVUC9VP| Sound unit, Pulse signal| 24 V AC/DC| 50 mA
XVUC020| Extender| 24 V AC/DC, 100…240 V (50/60 Hz)| 40 mA (24 V AC/DC), 35 mA (100…240 V AC)
XVUC020Q| Extender (Silver)| 24 V AC/DC, 100…240 V (50/60 Hz)| 40 mA (24 V AC/DC), 35 mA (100…240 V AC)
XVUC21B| DC body| 24 V AC/DC| 40 mA
XVUC21BQ| DC body (Silver)| 24 V AC/DC| 40 mA
XVUC21M| AC body NPN| 24 V AC/DC| 40 mA
XVUC21MP| AC body PNP| 24 V AC/DC| 40 mA
XVUC21MQP| AC body PNP (Silver)| 24 V AC/DC| 40 mA
XVUZ06| Flexible option| N/A| N/A
XVUZ01| Direct mounting plate (3 pins)| N/A| N/A

Product Usage Instructions

Connection to Protective Earth (PE)
DANGER: HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH. The XVUZ00 must be connected to protective earth (PE). The XVUZ05 adjustable pole must also be connected to protective earth (PE).
Failure to follow these instructions will result in death or serious injury.

Connecting XVUZ00 to Protective Earth (PE)
To connect the XVUZ00 to protective earth (PE), follow these steps

  1. Locate the XVUZ00 device.
  2. Identify the protective earth (PE) terminal on the device.
  3. Connect a suitable wire or cable to the PE terminal.
  4. Connect the other end of the wire or cable to a reliable ground or earth connection.

Connecting XVUZ05 Adjustable Pole to Protective Earth (PE)
To connect the XVUZ05 adjustable pole to protective earth (PE), follow these steps

  1. Locate the XVUZ05 adjustable pole.
  2. Identify the protective earth (PE) terminal on the adjustable pole.
  3. Connect a suitable wire or cable to the PE terminal.
  4. Connect the other end of the wire or cable to a reliable ground or earth connection.

Equipment Handling and Maintenance
EQUIPMENT DAMAGE AND INOPERATIVE EQUIPMENT: Use the screws or tools specified in this manual. Do not perform separation or disassembly not described in this manual.
Failure to follow these instructions can result in injury or equipment damage.

To handle and maintain the equipment properly, follow these guidelines

  1. Use only the screws and tools specified in the user manual for installation, operation, servicing, and maintenance.
  2. Do not attempt to separate or disassemble the equipment unless specifically described in the manual.
  3. If any issues or malfunctions occur, refer to the troubleshooting section of the user manual or contact qualified personnel for assistance.

FAQ (Frequently Asked Questions)

  • Q1: Can I use the XVUZ00 without connecting it to protective earth (PE)?
    A1: No, it is essential to connect the XVUZ00 to protective earth (PE) to ensure safety and prevent electric shock or other hazards.

  • Q2: What happens if I use screws or tools not specified in the manual?
    A2: Using screws or tools not specified in the manual can lead to equipment damage and may void the warranty. Always use the recommended screws and tools for proper installation and operation.

  • Q3: Can I disassemble or modify the product?
    A3: Disassembly or modification of the product may result in malfunction or failure. It is recommended to follow the instructions provided in the manual and avoid any unauthorized modifications.

XVUZ00 / XVUZ01● / XVUZ02● / XVUZ03 / XVUZ04 / XVUZ05

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH

  • Turn off power supply when installing and wiring.
  • Customer’s ½ inch NPT pole/tube accessory for use with XVUZ00 must be connected to protective earth (PE).
  • XVUZ05 adjustable pole must be connected to protective earth (PE).

Failure to follow these instructions will result in death or serious injury.

CAUTION
EQUIPMENT DAMAGE AND INOPERATIVE EQUIPMENT

  • Use the screws or tools specified in this manual.
  •  Do not perform separation or disassembly not described in this manual.

Failure to follow these instructions can result in injury or equipment damage.

  • Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
  • Disassembly or modification of this product may result in malfunction or failure.
  • No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.

A CONFIGURATION DRAWING

Drawing| Part number| Part name| Voltage| Consumption current|

Operating temperature

|

IP (*)

| Max. layer
---|---|---|---|---|---|---|---
24 V AC/DC (50/60 Hz)| 100…240 V AC (50/60 Hz)| 24 V AC/DC (50/60 Hz)| 100…240 V AC (50/60 Hz)
A1| | Top cover| Connect to body| | | -25…50 °C| IP65| 1
| Top cover (Silver)| | | -25…50 °C| IP65
A2| XVUC9S| Buzzer unit| 70 mA| 45 mA| -25…50 °C| IP54| 1
XVUC9SQ| Buzzer unit (Silver)| 70 mA| 45 mA| -25…50 °C| IP54
A3| XVUC23| Green LED unit| 50 mA| 40 mA| -25…50 °C| IP65| 5 (**)
XVUC24| Red LED unit| 40 mA| 35 mA| -25…50 °C| IP65
XVUC25| Orange LED unit| 40 mA| 35 mA| -25…50 °C| IP65
XVUC26| Blue LED unit| 50 mA| 40 mA| -25…50 °C| IP65
XVUC27| White LED unit| 50 mA| 40 mA| -25…50 °C| IP65
XVUC28| Yellow LED unit| 50 mA| 40 mA| -25…50 °C| IP65
A4| XVUC29| Multi-LED unit| 70 mA| 40 mA| -25…50 °C| IP65
A13| XVUC29P| Multi-LED unit, Pulse signal| 70 mA(only 24 VDC)| | -25…50 °C| IP65| 4
A12| XVUC9V| Sound unit| 400 mA| 135 mA| -20…50 °C| IP54| 1
A14| XVUC9VP| Sound unit, Pulse signal| 190 mA (only 24 VDC)| | -20…50 °C| IP54
A5| XVUC020| Extender| | | -25…50 °C| IP65| 1
XVUC020Q| Extender (Silver)| | | -25…50 °C| IP65
A6| XVUC21B| DC body| | | | | -25…50 °C| IP65| 1
XVUC21BQ| DC body (Silver)| | | | | -25…50 °C| IP65
A7| XVUC21M| AC body NPN| | | | | 0…50 °C| IP65
XVUC21MP| AC body PNP| | | | | 0…50 °C| IP65
XVUC21MQP| AC body PNP (Sliver)| | | | | 0…50 °C| IP65
A8| XVUZ06| Flexible option| | | | | -25…50 °C| IP55| 1
A9| XVUZ01| Direct mounting plate (3 pins)| | | | | -25…50 °C| IP65| 1
XVUZ01Q| Direct mounting plate (Silver) (3 pins)| | | | | -25…50 °C| IP65
XVUZ03| Direct mounting plate (2 pins)| | | | | -25…50 °C| IP65
XVUZ04| Direct mounting plate (4 pins)| | | | | -25…50 °C| IP65
A10| XVUZ02| Pole with plate| | | | | -25…50 °C| IP65
XVUZ02Q| Pole with plate (Silver)| | | | | -25…50 °C| IP65
A11| XVUZ05| Adjustment pole| | | | | -25…50 °C| IP65
A15| XVUZ00| 1/2 inch NPT conduit mounting| | | | | -25…50 °C| | 1

IP65, IP55 and IP54 are not part of UL certification.
4 when working with XVUC29P/XVUC9VP

MEMO

  • Do not change the combination or order of the components shown in the configuration drawing.
  • Do not connect adjustment pole (XVUZ05) to AC body (XVUC21M, XVUC21MP or XVUC21MQP).
  • When buzzer unit (XVUC9S, XVUC9SQ) or sound unit (XVUC9V) is used, the IP rating is IP54.
  • When flexible mounting (XVUZ06) is used, the IP rating is IP55.
  • IP65, IP55 and IP54 are not part of UL certification.

DIMENSIONS (Front View)

Schneider-Electric-XVUZ00-Series-Harmony-Fixing-Plate-
image-04

INSTALLATION

Schneider-Electric-XVUZ00-Series-Harmony-Fixing-Plate-
image-05 XVUZ00
Connected to ½ inch NPT customer supplied tubing

Schneider-Electric-XVUZ00-Series-Harmony-Fixing-Plate-
image-06 WIRING
If pulse signal technology units are used, please refer to wiring on pulse signal units Instruction Sheet.

Schneider-Electric-XVUZ00-Series-Harmony-Fixing-Plate-
image-07

HOW TO STACK

Schneider-Electric-XVUZ00-Series-Harmony-Fixing-Plate-
image-08

HOW TO OPERATE

MEMO

  • Turn off power supply when installing and wiring.

  • A fuse is not included and needs to be prepared by the user.

  • Field wiring terminal marking for wire type (75 °C [167 °F] copper conductors only).

  • Secure the wiring outside the body to keep stress from being applied on the terminal connection.

  • After wiring, do not extend, compress, or twist the body (XVUZ05).

  • For use on a flat surface of a Type 1 Enclosure.

  • 24V AC/DC input unit must be used with a Class 2 Power supply for direct mounting plate (XVUZ01, XVUZ01Q, XVUZ03, XVUZ04), pole mounting with plate (XVUZ02, XVUZ02Q) and adjustment pole (XVUZ05).

  • Maximum ambient temperature according to the UL standard: +50 °C (122 °F).

  • Released for Manufacturing

  • Printed on 2023/06/09

  • UK Representative

  • Schneider Electric Limited Stafford Park 5

  • Telford, TF3 3BL

  • United Kingdom

  • Authorized supplier in the Russian Federation

  • Теn. +7 (495) 777 99 90 Факс +7 (495) 777 99 92

  • Authorized supplier in the Republic of Kazakhstan

  • Tеn.: +7 (727) 357 23 57 Факс.: +7 (727) 357 24 39

  • www.se.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals