SCHMERSAL Micro Limit Switch Instruction Manual
- June 16, 2024
- SCHMERSAL
Table of Contents
- SCHMERSAL Micro Limit Switch
- Product Information
- About this document
- Product description
- Technical Data
- Safety classification – Safety outputs
- Mechanical data
- Mounting
- Electrical connection
- Set-up and maintenance
- Disassembly and disposal
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SCHMERSAL Micro Limit Switch
Product Information
Specifications
- Ordering Code: [insert ordering code]
- Special Versions: [insert special versions]
- Purpose: The product is designed to execute safety-related functions as part of an entire plant or machine.
- Warning about Misuse: It is important to use the product only for the applications authorized by the manufacturer.
- Exclusion of Liability: The information provided in this manual is subject to technical modifications and is provided without liability.
- Technical Data: [insert technical data]
Mounting
General Mounting Instructions
Follow these general instructions for proper mounting of the product.
Mounting of the Actuator
Refer to the specific instructions provided in the operating instructions
manual for proper mounting of the actuator.
Dimensions
Refer to the dimensions provided in the operating instructions manual for
accurate measurements.
Electrical Connection
General Information for Electrical Connection
Follow these general instructions for proper electrical connection of the
product.
Contact Options
Refer to the operating instructions manual for information on available
contact options and their usage.
Set-up and Maintenance
Follow the instructions provided in the operating instructions manual for
proper set-up and maintenance of the product.
Disassembly and Disposal
Disassembly
Refer to the specific instructions provided in the operating instructions
manual for proper disassembly of the product.
Disposal
Follow the proper disposal procedures for the product as described in the
operating instructions manual.
FAQ
-
Q: Who should carry out the operations described in the operating instructions manual?
A: All operations described in the operating instructions manual must be carried out by trained specialist personnel, authorized by the plant operator only. -
Q: What should I do before installing and putting the component into operation?
A: Before installation and putting the component into operation, make sure to read and understand these operating instructions and know all applicable legislations regarding occupational safety and accident prevention. -
Q: Can the product be used by private end consumers?
A: No, the products in Schmersal’s range are not intended to be used by private end consumers. -
Q: Where can I find further technical information?
A: Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
About this document
Function
This document provides all the information you need for the mounting, set-up
and commissioning to ensure the safe operation and disassembly of the
switchgear. The operating instructions enclosed with the device must always be
kept in a legible condition and accessible.
Target group of the operating instructions: authorised qualified
personnel
All operations described in the operating instructions manual must be carried
out by trained specialist personnel, authorised by the plant operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and putting
the component into operation.
The machine builder must carefully select the harmonised standards to be
complied with as well as other technical specifications for the selection,
mounting and integration of the components.
The information contained in this operating instructions manual is provided
without liability and is subject to technical modifications.
mhoUExplanation of the symbols used
- Information, hint, note: This symbol is used for identifying useful additional information.
- Caution:Failure to comply with this warning notice could lead to failures or malfunctions.
- Warning :Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.
Appropriate use
Products in Schmersal’s range are not intended to be used by private end
consumers.
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It is
the responsibility of the manufacturer of a machine or plant to ensure the
correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with the versions
listed below or for the applications authorised by the manufacturer. Detailed
information regarding the range of applications can be found in the chapter
“Product description”.
General safety instructions
The user must observe the safety instructions in this operating instructions
manual, the country specific installation standards as well as all prevailing
safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
Product description
Ordering code
Product type description : AZ 15 ZV(1)K-(2)-(3)
Special versions
For special versions, which are not listed in the ordering code, these
specifications apply accordingly, provided that they correspond to the
standard version.
Purpose
- The safety switches with separate actuator are suitable for sliding, hinged and removable safety guards, which need to be closed in order to ensure the necessary operational safety.
- The safety switches are used for applications, in which the hazardous situation is terminated without delay when the safety guard is opened.
- When the safety guard is opened, the NC contacts are positively opened and the NO contacts are closed.
- The safety switchgears are classified according to EN ISO 14119 as type 2 interlocking devices.
- The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level.
- The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards.
Warning about misuse
In case of improper use or manipulation of the safety switchgear, personal
hazards or damages to machinery or plant components cannot be excluded. There
are no residual risks, provided that the safety instructions as well as the
instructions regarding mounting, commissioning, operation and maintenance are
observed.
Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with the operating instructions
manual. The manufacturer shall accept no liability for damages resulting from
the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary repairs,
conversions and modifications to the device are strictly forbidden, the
manufacturer shall accept no liability for damages resulting from such
invasive work, arbitrary repairs, conversions and/or modifications to the
device.
Technical Data
General data
General data – Features
Safety classification – Safety outputs
- B10D Normally-closed contact (NC) 2,000,000 Operations
Mechanical data
Mechanical data – Dimensions
- Length of sensor 30 mm
- Width of sensor 52 mm
- Height of sensor 90 mm
Ambient conditions
- Degree of protection IP67
- Ambient temperature, minimum -30 °C
- Ambient temperature, maximum +80 °C
Ambient conditions – Insulation values
- Rated insulation voltage Ui 500 V
- Rated impulse withstand voltage Uimp 6 kV
Electrical data
- Thermal test current 10 A
- Switching principle Slow action
Electrical data – Safety contacts
- Voltage, Utilisation category AC-15 230 VAC
- Current, Utilisation category AC-15 4 A
- Voltage, Utilisation category DC-13 24 VDC
- Current, Utilisation category DC-13 4 A
Electrical data – Auxiliary contacts
- Voltage, Utilisation category AC-15 230 VAC
- Current, Utilisation category AC-15 4 A
- Voltage, Utilisation category DC-13 24 VDC
- Current, Utilisation category DC-13 4 A
Note about the safety classification
Basically suitable up to Cat. 1 / PL c.
With 2-channel usage with fault exclusion mechanism (if a fault exclusion to
the 1-channel mechanics is authorised) and suitable logic applicable up to
Cat. 3 / PL d
(Determined values can vary depending on the application-specific parameters hop, dop and tcycle as well as the load.)
If multiple safety components are wired in series, the Performance Level to EN ISO 13849-1 will be reduced due to the restricted error detection under certain circumstances
Mounting
General mounting instructions
Please observe the relevant requirements of the standards ISO 12100, ISO
14119 and ISO 14120.
The mounting dimensions are indicated on the rear of the component. The
enclosure must not be used as an end stop.
Any mounting position. The mounting position however must be chosen so that
the ingress of dirt and soiling in the used opening is avoided. The unused
openings must be sealed by means of slot sealing plugs (AZ 15/16 – 1476-1
available as accessory) after fitting.
Mounting of the actuator
See operating instructions Actuator.
The actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling of the screw heads).
Dimensions
All measurements in mm.
Electrical connection
General information for electrical connection
The electrical connection may only be carried out by authorised personnel
in a de-energised condition.
The contact labelling can be found in the wiring compartment of the switch. Appropriate cable glands with a suitable degree of protection are to be used.
- Settle length x of the conductor: 6 mm
- After wiring, dust and soiling must be removed from the wiring compartment. The safety switch is double insulated. The use of a protective ground connector therefore is not authorised.
Contact Options
Contacts are shown with safety guard closed. All NC contacts have positive
break B.
Set-up and maintenance
The safety function of the safety components must be tested. In the case of correct installation and adequate use, the safety switchgear features maintenance-free functionality. A regular visual inspection and functional test, including the following steps, is recommended:
- Check for free movement of the actuating element
- Check cable entry and connections
- Check the switch enclosure for damage
- Remove particles of dust and soiling
Adequate measures must be taken to ensure protection against tampering either
to prevent tampering of the safety guard, for instance by means of replacement
actuators.
Damaged or defective components must be replaced.
Disassembly and disposal
Disassembly
The safety switchgear must be disassembled in a de-energised condition only.
Disposal
The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.