Specifications

Catalog Number| EMT Conduit Size| Flange Thickness (FT)| Torque (TQ)| Ultimate Static Load (F)
---|---|---|---|---
BC8PSM| 1/2| 1/2 Max| 2.21 ft-lb| 15 lb
BC12PSM| 3/4| 1/2 Max| 2.21 ft lb| 15 lb
BC16PSM| 1| 1/2 Max| 2.21 ft lb| 15 lb

Features

  • Easy installation to beam flanges
  • Eliminates offset bending conduit

Warning
nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication, or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death, and/or void your warranty.

Contact Information

  • Europe Netherlands: +31 800-0200135
  • France: +33 800 901 793
  • Germany: 800 1890272
  • Other Countries: +31 13 5835404
  • APAC Shanghai: +86 21 2412 1618/19
  • Sydney: +61 2 9751 8500

Brands
Our powerful portfolio of brands:

  • nVent.com
  • CADDY
  • ERICO
  • HOFFMAN
  • RAYCHEM
  • SCHROFF
  • TRACER

Note
nVent reserves the right to change specifications without notice.

Product Usage Instructions

Installation

  1. Ensure that the beam flanges are clean and free from debris.
  2. Select the appropriate BC-PSM Conduit to Beam Clamp based on the EMT conduit size and flange thickness.
  3. Place the clamp over the beam flanges, aligning the conduit opening with the desired position.
  4. Tighten the screws on the clamp using a torque wrench, applying a torque of 2.21 ft-lb.
  5. Verify that the clamp is securely fastened to the beam flanges.

Conduit Installation

  1. Insert the EMT conduit into the conduit opening of the BC-PSM Conduit to the Beam Clamp.
  2. Ensure that the conduit is fully inserted and aligned with the desired position.
  3. Secure the conduit in place using appropriate fittings and fasteners.

Maintenance
Regularly inspect the BC-PSM Conduit to Beam Clamp for any signs of damage, wear, or loosening. If any issues are identified, tighten or replace the clamp as necessary.

Removal

  1. Disconnect and remove any conduit connected to the BC-PSM Conduit to the Beam Clamp.
  2. Loosen and remove the screws on the clamp using a torque wrench.
  3. Remove the clamp from the beam flanges.

Cleaning
Use a clean cloth or brush to remove any dirt or debris from the BC-PSM Conduit to Beam Clamp. Avoid using harsh chemicals or abrasive materials that may damage the clamp’s finish.

FAQ (Frequently Asked Questions)

  • Q: Can I use the BC-PSM Conduit to Beam Clamp with different types of conduit?
    A: The BC-PSM Conduit to Beam Clamp is designed specifically for use with EMT (Electrical Metallic Tubing) conduit.

  • Q: What is the maximum flange thickness that the BC-PSM Conduit to Beam Clamp can accommodate?
    A: The BC-PSM Conduit to Beam Clamp can accommodate a maximum flange thickness of 1/2 inch.

  • Q: What is the torque specification for tightening the screws on the BC-PSM Conduit to Beam Clamp?
    A: The recommended torque for tightening the screws on the BC-PSM Conduit to Beam Clamp is 2.21 ft-lb.

FEATURES

  • Easy installation to beam flanges
  • Eliminates offset bending conduit

SPECIFICATIONS

  • Finish: nVent CADDY Armour
  • Material: Spring Steel

Catalog Number| EMT Conduit Size| Flange Thickness(FT)| Torque(TQ)| Ultimate Static Load(F)
---|---|---|---|---
BC8PSM| 1/2″| 1/2″ Max| 2.21 ft- lb| 15 lb
BC12PSM| 3/4″| 1/2″ Max|  | 15 lb
BC16PSM| 1″| 1/2″ Max| 2.21 ft- lb| 15 lb

DIAGRAMS

WARNING

nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication, or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury, and death and/or void your warranty.

Contact Information

North America

  • +1.800.753.9221
  • Option 1 – Customer Care
  • Option 2 – Technical Support

Europe

  • Netherlands: +31 800-0200135
  • France: +33 800 901 793

Europe

  • Germany: 800 1890272
  • Other Countries: +31 13 5835404

APAC

  • Shanghai: + 86 21 2412 1618/19
  • Sydney: +61 2 9751 8500

Our powerful portfolio of brands:
nVent.com

  • CADDY
  • ERICO
  • HOFFMAN
  • RAYCHEM
  • SCHROFF
  • TRACER

© 2023 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners.

nVent reserves the right to change specifications without notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

nVent Caddy User Manuals

Related Manuals