VIZULO Stork Little Sister LED Street Luminaire Instruction Manual
- June 12, 2024
- VIZULO
Table of Contents
- VIZULO Stork Little Sister LED Street Luminaire
- Product Information
- Product Usage Instructions
- Average Netto Weight
- Assembly
- Installation Instructions
- Energy efficiency class of contained light source(s)
- Mounting instructions
- Maintenance and repair
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VIZULO Stork Little Sister LED Street Luminaire
Product Information
- Product: VIZULO Stork Little Sister LED street luminaire
- Mounting instruction: Montzas instrukcija M
- Certifications: IEC IP66 IK10, EN 60598
- Power Input: 2200 – 240 V AC
- Weight: 3.50 kg – 4.20 kg (depending on model)
- Dimensions: 433 SCd = 0.033 m2, 170 SCd = 0.019 m2
- Possible combinations: Refer to the manual for combinations
- Luminaire Mounting Angle: Acceptable angles are 15° to 180°, unacceptable angle is 260° relative to the ground
Luminaire Power and CCT:
- Oslon Square: 5W to 80W, 5700K, RG1 risk group
- Luxeon 5050: 5W to 80W, 5700K, RG1 risk group
- Duris S8: 5W to 80W, 5700K, RG1 risk group
- Energy Efficiency Class of Contained Light Source(s): Standard A, B, C, D, E, F, G
- MCB/Inrush Current Table: Refer to the manual for detailed table
Product Usage Instructions
- Ensure the power input is within the range of 2200 – 240 V AC.
- Select the appropriate luminaire model and weight based on your requirements.
- Refer to the manual for possible combinations of the luminaire.
- Mount the luminaire at an acceptable angle relative to the ground (15° to 180°).
- Choose the desired luminaire power and CCT based on your lighting needs.
- Consider the energy efficiency class of the contained light source(s) for optimal performance.
- Consult the MCB/Inrush Current Table for guidance on selecting the appropriate LED driver.
Note: For detailed instructions on mounting, wiring, and maintenance, please refer to the complete user manual.
Depends on configuration. Check label or technical specification.
Dimensions
Average Netto Weight
- SRUE □□□ □□□ □□□ AA016 □□N □□□ 3.50 kg
- SRU □□□ □□□ □□□ AF032 □□N □□□ 3.50 kg
- SRUE □□□ □□□ □□□ AA016 □□R □□□ 4.10 kg
- SRU □□□ □□□ □□□ AF032 □□R □□□ 4.10 kg
- SRUE □□□ □□□ □□□ AA016 □□P □□□ 4.20 kg
- SRU □□□ □□□ □□□ AF032 □□P □□□ 4.20 kg
Assembly
Possible combinations
WARNING!
- Do not touch LED modules!
- Do not put any tools or other items on LED modules!
- In case any LED is physically damaged (example shown below) the warranty is void.
- Acceptable luminaire with ZHAGA socket mounting angle relative to the ground.
- Acceptable luminaire mounting angle relative to the ground.
- Unacceptable luminaire mounting angle relative to the ground.
These limitations only apply when mounting the luminaire outdoors!
LED | Power | CCT | Risk group | Remarks |
---|---|---|---|---|
Oslon Square | 5 … 80 W | ≤ 5700 K | RG1 after TBC m* | Label required |
Luxeon 5050 | 5 … 80W | ≤ 5700 K | RG1 after TBC m* | Label required |
Duris S8 | 5 … 80W | ≤ 5700 K | RG1 after TBC m* | Label required |
The luminaire should be positioned so that prolonged staring into the luminaire is not expected from a distance closer than shown in the table above.
Installation Instructions
ATTENTION! In case of NEMA/ZHAGA Socket.
IP66 applies only for luminaire body and for connection between luminaire body
and NEMA/ZHAGA Socket, and do not applies to any mounted control device and
connection between control device and NEMA/ZHAGA Socket.
Energy efficiency class of contained light source(s)
Standard
| CRI
---|---
70| 80| 90
CCT| 1800| F| |
2200| E| |
2500| E| |
2700| D| E| F
3000| D| E| F
4000| C| D| E
5000| C| D| E
2700| C| D| E
6500| C| | E
Eco
| CRI
---|---
70| 80| 90
CCT| 2200| E| F|
2700| E| E| F
3000| E| E| F
4000| D| E| F
5000| D| E| F
5700| D| E| F
6500| D| E|
MCB/Inrush current table
Tridonic LED driver (No dim/ Midnight dimming/ DALI)
Standard/ High density| In-rush current
(peak/duration)
| B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A|
C32A| C40A
4-6 LED, 5-10W| 9 A (253 μs)| 28| 36| 44| 51| 63| 81| 102| 46| 60| 73| 85|
106| 136| 170
6-12 LED, 11-26W| 15 A (226 μs)| 19| 25| 30| 37| 46| 59| 74| 31| 41| 50| 61|
76| 97| 122
12-20 LED, 20-43W| 25 A (236 μs)| 12| 16| 20| 26| 32| 41| 52| 20| 26| 33| 43|
53| 68| 86
20-28 LED, 30-64W| 32 A (335 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 16| 21|
26| 33| 42
28-32 LED, 45-80W| 42 A (238 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 17| 22|
27| 35| 44
Eco| | B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A|
C25A| C32A| C40A
4-4 LED, 5-11W| 9 A (253 μs)| 28| 36| 44| 51| 63| 81| 102| 46| 60| 73| 85|
106| 136| 170
4-4 LED, 12-20W| 15 A (226 μs)| 19| 25| 30| 37| 46| 59| 74| 31| 41| 50| 61|
76| 97| 122
4-8 LED, 20-38W| 25 A (236 μs)| 12| 16| 20| 26| 32| 41| 52| 20| 26| 33| 43|
53| 68| 86
8-12 LED, 30-57W| 32 A (335 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 16| 21| 26|
33| 42
12-16 LED, 45-75W| 42 A (238 µs)| 6| 8| 10| 13| 16| 20| 26| 10| 13| 17| 22|
27| 35| 44
Tridonic LED driver (Zhaga)
Standard/ High density| In-rush current
(peak/duration)
| B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A|
C32A| C40A
4-6 LED, 5-11W| 8 A (470 μs)| 19| 25| 30| 38| 47| 60| 76| 31| 41| 50| 63| 78|
100| 126
6-12 LED, 12-26W| 15 A (316 μs)| 16| 21| 25| 33| 41| 52| 66| 26| 35| 41| 55|
68| 88| 110
12-20 LED, 20-43W| 20 A (346 μs)| 11| 14| 17| 22| 27| 35| 44| 18| 23| 28| 36|
45| 57| 72
20-24 LED, 30-64W| 28 A (270 µs)| 10| 13| 16| 20| 25| 32| 40| 16| 21| 26| 33|
41| 52| 66
| | | | | | | | | | | | | | |
Eco| | B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A|
C25A| C32A| C40A
4-4 LED, 5-11W| 8 A (470 μs)| 19| 25| 30| 38| 47| 60| 76| 31| 41| 50| 63| 78|
100| 126
4-4 LED, 12-20W| 15 A (316 μs)| 16| 21| 25| 33| 41| 52| 66| 26| 35| 41| 55|
68| 88| 110
4-8 LED, 20-39W| 20 A (346 μs)| 11| 14| 17| 22| 27| 35| 44| 18| 23| 28| 36|
45| 57| 72
8-12 LED, 30-57W| 28 A (270 µs)| 10| 13| 16| 20| 25| 32| 40| 16| 21| 26| 33|
41| 52| 66
Terms of use and maintenance
Before luminaire is turned on, it should be mounted according with this
mounting instruction or any other applicable regulations.
Mounting instructions
Mounting of luminaire must be performed by a qualified person according with following instructions:
- The warranty of luminaire does not apply, if the mounting of luminaire has been performed in precipitation (rain, snow, hail).
- The warranty of luminaire does not apply, if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
- The warranty of luminaire does not apply, if it has been used in an unsuitable ambient temperature or has been supplied by voltage outside of the specified range.
- The warranty of luminaire does not apply, if the LED driver program has been changed in any way.
- The warranty of the luminaire does not apply, if the logged history data of the LED driver has been deleted without the permission of VIZULO.
- The warranty of luminaire does not apply, if it has been mounted in unspecified angles or upside down (luminaire glass directed up), or it has been completely submerged under water.
Safety instructions
Any actions with the luminaire must be performed by a qualified person, who is
certified according with national regulations and requirements. To prevent any
accidents person installing the luminaire must follow national safety
requirements and following instructions:
- The label containing technical parameters of the luminaire has to be studied before the work on it has begun.
- Any luminaire build or design changes are prohibited.
- The luminaire must be used in good technical condition and according with this instruction.
- Only VIZULO authorized spare parts and accessories can be used to repair the luminaire.
- The repair of luminaire has to be performed by a qualified and certified person.
Maintenance and repair
Luminaire has to be disconnected from electrical grid before it is opened and/or repaired!
- The person working with the luminaire must follow national regulations and legislations that apply to maintenance and testing of electrical or electronic appliances.
- The luminaire may need to be cleaned depending on its environment.
- Only a damp cloth or a sponge may be used to clean the luminaire.
- Use only household detergents diluted by water.
- Only VIZULO authorized spare parts may be used for the luminaire.
- Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
- LED modules, lens and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoor to avoid water entering the luminaire.
- Spare parts (lens, LED modules and drivers) should be ordered from the information available on the luminaire label.
SIA VIZULO
Laucu Lejas, Iecava, Latvia, LV-3913
www.vizulo.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>