TANITA RD901PRO Multi Frequency Body Composition Monitor User Guide

June 6, 2024
TANITA

Quick Start Guide
InnerScan PRO™
Multi Frequency Body Composition Monitor RD-901 PRO

Features and Functions

See the instruction manual for details.www.tanita.com

For your Safety

This section explains precautionary measures to be taken to avoid injury to the users of this device and others and to prevent damage to property. Please familiarize yourself with this information to ensure the safe operation of this equipment.

Warning
Failure to follow instructions highlighted with this mark could result in death or severe injury.
Caution
Failure to follow instructions highlighted with this mark could result in injury or damage to property.
**** This mark indicates actions that are prohibited.
This mark indicates instructions that must always be followed.

**** Warning

Prohibited
This monitor must not be used by people with pacemakers or other medical implants.
This monitor passes a weak electrical current through the body which could interfere with and cause the malfunction of electrical medical implants, resulting in serious harm to the user
Interpretation of measurements (e.g. evaluation of measurements and formulation of exercise programs based on the measurements) must be performed by a professional.
Implementing weight loss measures and exercise programs based on self-analysis could be harmful to your health. Always follow the advice of a qualified professional
Do not step on the edge of the platform. Do not jump onto the platform.
Doing so may cause you to fall or slip, resulting in serious injury
Do not place this monitor on a slippery surface such as a wet floor,
Doing so may cause you to fall or slip, resulting in serious injury. It may also cause water to get inside the monitor resulting in damage to internal components
Do not drop any objects onto the monitor. Avoid excessive impact or vibration to the monitor.
Doing so may damage the glass, resulting in injury

**** Caution

Prohibited
Do not stand on the display screen or control panel.
Do not insert your fingers into gaps or holes.
Doing so may result in injury.
Do not use rechargeable batteries.
Do not use old batteries together with new batteries, or a mix of different types of batteries at the same time,
Doing so may cause battery fluid to leak or the batteries to become excessively hot and rupture, resulting in damage to the monitor or injury
Never allow an infant or small child to carry the monitor.
The child may drop the monitor, resulting in injury
This monitor is intended for home use only
This monitor is not intended for professional use including in hospitals, medical or fitness facilities. It is not equipped with the components required for heavy usage. Using the monitor in a professional location will invalidate the warranty

Connecting to your smartphone

Download the App & Turn Bluetooth On  sit the App Store/Google Play Store to download the ‘Healthy Edge Mobile” App Download the App & Turn Bluetooth On Visit the App Store/Google ay Store to download the ‘Healthy Edge Mobile” App Turn the Bluetooth setting on Turn the Bluetooth setting on

Set your “Profile
Open the App
Open Settings and then register your profile details
Touch «Settings” to return to the previous screen

Server”
Fill out your info registered at my.tanita.com in Sever” under Settings”
Measurement results can De boa. led to my.tanita.com after measurement ouch Sae”t return to the previous screen

Seale” Settings
Touch + and follow the instructions in the App to register your platform return to the previous $0I80

Taking Measurements

Measurement
Touch, and then follow the instructions in the App

Measurement Results
Results are automatically sent to your smart. phone and are displayed in the App Touch Save” to store the results in the App
If you do not have your smartphone when taking measurements

Step onto the platform to take measurements. Data from a maximum of 10 measurements is saved in the platform. Saved data is sent to your smartphone together with new measurements the next time your smartphone is connected to the platform when taking measurements.
Setting the Date and Time

  1. Press 0.
  2. Use /wand Oto set the date and time. ****

Registering Personal Data

  1. Press 0.
  2. Use /wand Oto register the personal data number (1 – 4), date of birth, sex (male/female/ male athlete/female athlete) and height.

Who should use Athlete mode?
Adults from the age of 18 years who either:

  • Train or exercise for 12 hours or more a week and have been doing so for at least six months.
  • Are bodybuilders.
  • Are professional athletes who want to monitor their progress at home.
  • People who have a lifetime history of fitness—who used to do more than 12 hours a week—but do less now.

After “0.01b6 appears on the display screen, step onto the monitor with bare feet to measure your body composition.
From the next time, just step onto the platform to take measurements.
Data from a maximum of 10 measurements are saved in the platform.
Touch ‘Get Old” in the App to send results previously saved in the platform to the smartphone.

Measurement Result

Place the monitor on a hard, flat surface where there is minimal vibration to ensure safe and accurate measurement.
Avoid excessive impact or vibration to the monitor.
Doing so may damage the monitor or cause it to malfunction,or may cause setting to be erased.
Do not use or store this monitor In the following locations.

  • locations that are exposed to direct sunlight, near to heaters, or exposed directly to air from air conditioning units, etc.
  • locations where there are severe temperature changes or a large amount of vibration.
  • locations with high levels of humidity or moisture
  • Doing so may damage the monitor or cause it to malfunction.

Do not step on the monitor when your body is wet (immediately after a shower or bath, etc.)
Be sure to thoroughly dry your body and feet before using the monitor. Failure to do so may cause you to slip or fall, resulting in injury. Also, the monitor cannot take accurate measurements if your body or feet are wet.
Keep away from water.
Do not use boiling water, benzene, thinner, etc. to clean the monitor.
If the monitor becomes dirty, soak a soft cloth in water or neutral household detergent, wring it out thoroughly and wipe the monitor clean, then use a dry cloth to wipe the monitor dry.
Do not attempt to disassemble the monitor.
Do not modify this equipment In any way.
Do not wash the monitor in water. Do not submerge this monitor in water.
Doing so may damage the monitor or cause it to malfunction.
Be sure to Insert the batteries with the polarities (+, -) In the correct position.
If the batteries are incorrectly inserted, battery fluid may leak and damage the floor. (If you do not intend to use this monitor for a long period of time, it is advisable to remove the batteries before storage.)
Do not use the monitor near other products such as microwave ovens that emit electromagnetic waves
Doing so may cause the monitor to malfunction, preventing accurate measurements.
Another person should assist persons with disabilities who may not be able to take a measurement alone.

Getting Accurate Readings

To ensure accuracy, readings should be taken without clothing and under consistent conditions of hydration. If you do not undress, always remove your socks or stockings, and be sure the soles of your feet are clean before stepping on the measuring platform. Be sure that your heels are correctly aligned with the electrodes on the measuring platform. Don’t worry if your feet appear too large for the unit accurate readings can still be obtained if your toes overhang the platform. it is best to take readings at the same time of day. Try to wait about two hours after rising, eating, or hard exercise before taking measurements. While readings taken under other conditions may not have the same absolute values, they are accurate for determining the percentage of change as long as the readings are taken in a consistent manner. To monitor progress, compare weight and body fat percentage taken under the same conditions over a period of time.
Note
An accurate reading will not be possible if the soles of your feet are not clean, or if your knees are bent or you are in a sitting position.

Preparations before Use

Insert the batteries
Please note that the included batteries from the factory may have decreased energy levels over time

Set your location code
Different locations across the world have different gravitational pulls. These differences affect the accuracy of the weight measurement. You can obtain the most accurate weight readings by selecting the correct gravity setting on the scale according to your geographical location

  1. When the power is off, press and hold the button
  2. Refer to the map enclosed, and press thee buttons to select your location code
  3. Press the O button to enter and save the setting

Specifications ………………………RD-901 PRO
Weight Capacity …………………………………200 kg (440 IbX31st 6 lb)
Weight Increments…………………………… 0-100 kg/0.05 kg 100-200 kg/0.1 kg 0-200 lb/0.1 lb 200-440 lb/0.2 lb 0-31st 6 lb/1 lb
Body Fat %……………………………….. 7-99 years old Body Mass Index 7-99 years old Muscle Mass 18-99 years old
Muscle Quality Score………………………. 18-99 years old
Physique Rating ………………………………………..18-99 years old
Bone Mass ………………………………….18-99 years old
Visceral Fat………………………………………… 18-99 years old
Basal Metabolic Rate……………………………… 18-99 years old
Metabolic Age…………………………………………. 18-99 years old
Body Water %……………………………. 18-99 years old
Personal Data………………………………. 4 memories
Power Supply 4 …………………………..xAA Alkaline batteries(included)
Power Consumption……………………. 250mA maximum
Measuring Current……………………………….. 50kHz, 5 kHz, ‘IOWA
Communication Method…………………………………… Bluetooth Low Energy technology

  • The product design and speollbstkIns may be changed at any time without prior notice.
  • AppIt the Apple logo. and Phone is trademarks of Apple hc.. registered In the U.S. and other countries. App Store is a sconce Mark of Apple Inc.
  • Google Play and the Google Play logo ate trademarle3 of Google
  • Android lo trademark of Googe LLC.
  • The SuetoothOle WWI mane and logos are registered trademarks owned by Bluetooth SIG. Inc. and any use of such marks by Tanita Corporation is under Icons°.

USA Federal Communications Commission
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio or television technician for help.

Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Tanita Corporation may void the user’s authority to operate the equipment.

Manufacturer TANITA Corporatio n
1-14-2 Maeno-cho,
Itabashi-ku, Tokyo
174-8630 Japan
TEL: +81-(0)3-3968-7048
www.tanita.co.jp| EU Representative TANITA Europe B.V. Hoogoorddreef 56-E, 1101 BE
Amsterdam, the Netherlands
TEL +31-(0)20-560-2970
FM: +31-(0)20-560-2988
www.tanita.eu| TANITA Corporation of America, Inc.
2625 South Clearbrook Drive,
Arlington Heights, Illinois 60005 U.S.A.
TEL: +1-847-640-9241
FAX: +1-847-640-9261
www.tanita.com
---|---|---
TANITA Health Equipment H.K. Ltd.
Unit 301-303. Wog On Plaza. 3/F.. 62 Mody Road. Tsimshatsui East.
Kowloon. Hong Kong
TEL: +852-2834-3917
FAX +852-2838-8667 www.tanita.asia| TANITA (Shanghai) Trading Co., Ltd.
Room 8005, 877 Huai Hai Zhong Lu.
Shanghai, The People’s Republic of China
TEL: +86-21-6474-6803
FAX: +86-21-6474-7901
moy.tanita.com.cn| TANITA India Private Limited
A-502. Mittal Commercial. Off. M.V. Road (Andheri Kurla Road). Mara!, Andheri- East. Mumbai 400059.
Maharashtra. India
TEL: +91-81-697-28173
www.Tanita.co.in

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TANITA User Manuals

Related Manuals