ACS Standard Edition
Version 6.2.1 Release Notes Keithley Instruments
28775 Aurora Road
Cleveland, Ohio 44139
1-800-833-9200
tek.com/keithley
General information
This document describes the features added to the Keithley Instruments
Automation Characterization Suite (ACS) Standard Edition software (version
6.2.1).
The Keithley Instruments ACS Standard Edition software supports component
characterization testing of packaged parts and wafer-level testing using
probers. ACS Standard Edition software can be installed on any computer,
including Keithley Instruments Model 4200A-SCS Parameter Analyzer and Model
4200 Semiconductor Characterization System (4200-SCS).
Supported operating systems
ACS Standard Edition software is supported on the following operating systems:
Microsoft Windows®
11, 64-bit
Microsoft Windows 10, 64-bit
Microsoft Windows
10, 32-bit
Microsoft Windows 7, 64-bit (with Service Pack 1)
Microsoft Windows 7, 32-bit (with Service Pack 1)
ACS Standard revision history
Version | Release date |
---|---|
6.2.1 | March 2023 |
6.2 | November 2022 |
6.1 | March 2022 |
6 | August 2021 |
5.4 | February 2021 |
5.3 | December 2017 |
5.2.1 | September 2015 |
5.2 | December 2014 |
5.1 | May 2014 |
5 | February 2013 |
4.4 | December 2011 |
4.3.1 | June 2011 |
4.3 | March 2011 |
4.2.5 | October 2010 |
4.2 | June 2010 |
Install ACS
To install ACS software:
- Log in to your computer as an Administrator.
- Open the ACS executable file.
- Select Yes if you have an older version of ACS installed.
- Follow the instructions to specify how you want to install the software on your system.
Once the updated version of ACS is installed, the older version is renamed.
You can copy the projects and libraries from the previous version using the
following steps.
To copy and paste folders:
- Find the C:\ACS_DDMMYYYY_HHMMSS\Projects\ folder; copy and paste to the current C:\ACS\Projects folder.
- Find the C:\ACS_DDMMYYYY_HHMMSS\library\pyLibrary\PTMLib\ folder; copy and paste to the current C:\ACS\library\pyLibrary\PTMLib\ folder.
- Find the C:\ACS\DDMMYYYY_HHMMSS\library\26library\ folder; copy and paste to the current C:\ACS\library\26library\ folder.
NOTE
ACS 6.2.1 is based on the Python® 3.7 programming language. If you customized
your projects in a previous version of ACS you may need to change the projects
created in the older version of ACS, which includes the Python language test
module (PTM) script libraries. You can go to this site to review the Python
changes for more detail: https://docs.python.org/3/whatsnew/3.7.html#porting-
to-python-37
Install applications on a 4200A-SCS
If you are installing ACS on a 4200A-SCS Parameter Analyzer, you will see the
following dialog box indicating that the applications identified are needed
for installation. Make sure you select Do not close applications and Next to
install (see the following figure). If you select Automatically close the
applications, you must restart the computer after the installation is
completed. Install applications on a system with NI-488.2
drivers
If you are installing ACS on a system that contains NI-488.2 drivers, you will
see the following dialog box indicating that the applications identified are
needed for installation. Make sure you select Do not close applications and
Next to install (see the following figure). If you select Automatically close
the applications, you must restart the computer after the installation is
completed.
Supported models and test configurations
ACS software is used with the following Keithley Instruments in a variety of different test configurations. The ACS Fundamentals Reference Manual (part number ACS-914-01) and ACS Advanced Features Reference Manual (part number ACS-908-01) contain detailed information about the supported hardware and test configurations.
- Perform multigroup testing with Series 2600B System SourceMeter® instruments and Series 2400 SourceMeter® instruments using ACS software installed on a personal computer or laptop.
- Control hardware using ACS software installed on the Model 4200A-SCS Parameter Analyzer or Model 4200-SCS.
- Perform combined group testing with a 4200A-SCS Parameter Analyzer or 4200-SCS, and Series 2600B SourceMeter® instruments using the combined test-execution engine in ACS software.
- Control other external GPIB, LAN, or USB instruments using ACS software installed on a personal computer or laptop.
The following table summarizes the instruments supported in the ACS test libraries.
Instrument type | Supported models |
---|---|
SMU instruments | 2600B Series: 2601B-PULSE (DC only), 2601B, 2602B, 2604B, |
2611B, 2612B, 2614B, 2634B, 2635B, 2636B
2600A Series: 2601A, 2602A, 2611A, 2612A, 2635A, 2636A
2400 Graphical Touchscreen Series SMU (KI24XX TTI): 2450, 2460, 2460-NFP, 2460
-NFP-RACK, 2460-RACK, 2461, 2461-SYS, 2470
2400 Standard Series SMU: 2401, 2410, 2420, 2430, 2440
2606B High Density SMU
2650 Series for High Power: 2651A, 2657A
Parameter analyzers| 4200A and the following modules: 4210-CVU, 4215-CVU
4225-PMU/4225-RPM, 4225-RPM-LR, 4200-SMU, 4201-SMU, 4210-SMU, 4211-SMU,
4200-PA, 4200A-CVIV
DMMs| DMM6500, DMM7510, 2010 Series
Switching and data acquisition systems| DAQ6510, 707A/B, 708A/B, 3700A
Pulse generators| 3400 Series
The following probers are supported in ACS:
Probers| Manual Prober Micromanipulator 8860 Prober
Suss MicroTec PA200/Cascade CM300 Prober Cascade 12000 Prober
Cascade S300 Prober Electroglas EG2X Prober Electroglas EG4X Prober TEL P8/P12
Prober TEL 19S Prober
Tokyo Semitsu TSK9 (UF200/UF3000/APM60/70/80/90) Prober Wentworth Pegasus 300S
Prober with SRQ check Micromanipulator P300A Prober
Yang Sagi3 Prober with SRQ check Signatone CM500 Prober (WL250) TEL T78S/80S
Prober
MPI SENTIO Prober Semiprobe SPFA Prober MJC AP-80 prober
Apollowave AP200/AP300 Prober
Vector Semiconductor AX/VX Series prober
---|---
NOTE
The graphical interactive test module (ITM) supports Series 24xx Touch Test
Invent® (TTI) instruments and 26xx instruments at the same time. The 24xx
instrument should be connected as the primary instrument and the 26xx
connected as the subordinate.
You can control any test script processor (TSPTM) instrument using script test
module (STM) scripts. You can control any instrument using the Python language
test module (PTM) script, including instrumentation from other vendors.
Also, existing ACS STM and PTM libraries support specific instruments based on
the library definition.
Supported communication interfaces
- GPIB
- LAN (Auto Scan and LAN)
- USB
- RS-232
If you are using a RS-232 connection, the instrument is not automatically
added to the hardware configuration. You will have to add instruments
connected with RS-232 manually. Change the hardware configuration file that is
in the following directory on your computer:
C:\ACS\HardwareManagementTool\HWCFG_pref.ini. In this file you must change the
baud rate, parity, byte, and stopBit settings. Review the following figure for
details.
Software license
ACS allows you to create tests, manipulate settings, and view previous data without a license. However, you must have a license for ACS to control and retrieve data from a physical instrument. You can launch a one-time, 60-day trial for ACS after the initial installation. Once the license expires, you must purchase a full license to use the software.
License management
The ACS software license is managed using the Tektronix Asset Management
System (TekAMS).
To generate a license file:
- You must submit your Host ID to TekAMS. For more information about TekAMS, see tek.com/products/product-license.
- To find the host ID, open the License Manage dialog box from the ACS Help menu. Select License > Host ID > Click to copy the Host ID.
- Select Install.
ACS Standard version 6.2.1
Enhancements
Hardware configuration
Issue number: | ACS-652 |
---|---|
Enhancement: | Added support in ACS to configure the DMM6500 instrument and the |
DAQ6510 instrument
using TSP-Link.
ACS software and libraires
Issue number: | ACS-624 |
---|---|
Enhancement: | Added hold time during testing for the sweep-step, which is |
enabled for each step.
Issue number:| ACS-544
Enhancement:| Added the option to stop testing during compliance and power
compliance for each step.
Resolved issues
Issue number: | ACS-667 |
---|---|
Symptom: | When running multiple group testing using TSP-Link with a 2430 |
instrument in Group3, there
is no output after the test has completed.
Resolution:| This issue has been corrected.
Issue number:| ACS-666
Symptom:| A hardware scan error occurs when connecting TSP-Link using 24xx TTI
SMU instruments.
Resolution:| This issue has been corrected.
Issue number:| ACS-665
Symptom:| A hardware scan error occurs when connecting multiple 2410 and 2430
instruments.
Resolution:| This issue has been corrected.
Issue number:| ACS-663
Symptom:| The error code –1014 is due to the MPI prober failing when using the
PrRelReturn function.
Resolution:| This issue has been corrected.
Issue number:| ACS-662
Symptom:| The voltage drain output is not correct when used with the 100 A
compliance.
Resolution:| This issue has been corrected.
Issue number:| ACS-661
Symptom:| When combining the 100 A compliance for the ITM, it will not refresh
with new data.
Resolution:| This issue has been corrected.
Issue number:| ACS-660
Symptom:| There is no data output when pulse transient mode for the ITM is
enabled.
Resolution:| This issue has been corrected.
Issue number:| ACS-657
Symptom:| Selecting the pulse sweep function in ITM mode does not work.
Resolution:| This issue has been corrected.
Issue number:| ACS-655
Symptom:| The Sweep2V and Sweep2I from the ITM function list have been removed
from ACS
software testing.
Resolution:| This issue has been corrected.
Issue number:| ACS-648
Symptom:| If the stress count is too high during a Subsite Loop, the test will
not complete.
Resolution:| This issue has been corrected.
Issue number:| ACS-554
Symptom:| ACS software will crash when you select the Ron_5A_PULSE_check
function.
Resolution:| This issue has been corrected.
Software compatibility
Issue number: | N/A |
---|---|
Resolution: | When you start ACS on the 4200A-SCS system with Clarius software |
version 1.4 or newer (with the Windows 10 operating system), a warning message may appear indicating that Keithley External Control Interface (KXCI) did not start successfully. Select Cancel to dismiss the warning.
To manually configure the compatibility settings:
- Right-click the ACS icon and select Properties.
- Open the Compatibility tab.
- Select Run this program as an administrator and select OK to save.
Usage note
Issue number: | N/A |
---|---|
Resolution: | If you install a KUSB-488B GPIB driver, you will see the |
following message. You must select
the Keithley Command Compatible option. Select Next to continue the
installation.
PA-1008 Rev. U March 2023
References
- Keithley Instruments & Products | Tektronix
- Product License | Tektronix
- What’s New In Python 3.7 — Python 3.12.1 documentation
- What’s New In Python 3.7 — Python 3.12.2 documentation
- Keithley Instruments & Products | Tektronix
- Product License | Tektronix